Desa LSL3124N - Manual

Desa LSL3124N

Desa LSL3124N – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – WARNING: Do not allow fans to blow directly into; SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls; TABLE OF CONTENTS
  • Page 3 – Continued; LOCAL CODES; CAUTION: Do not remove the data plates from the
  • Page 4 – WARNING: This heater shall not be installed in a; PRODUCT FEATURES; OPERATION; PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Meadowbrook Oak Logs with Thermostat Control
  • Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors; WARNING: If the area in which the heater may be
  • Page 7 – Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; INSTALLATION; LOG SIZING REQUIREMENTS
  • Page 8 – Figure 4 - Minimum Clearance for Combustible to Wall; Noncombustible; Minimum Noncombustible Material Clearances; If Not Using Mantel; Installing Damper; If Using Mantel
  • Page 9 – Determining Minimum Mantel Clearance; Figure 6 - Minimum Mantel Clearances Without Using Hood; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain
  • Page 10 – Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator; Area of Various Standard; Chimney; WARNING: You must secure this heater to fire-; Installation Items Needed; Figure 10 - Attaching Damper Clamp
  • Page 11 – Figure 13 - External Regulator With Vent Pointing Down; Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Figure 12 - Attaching Heater to Fireplace Floor; Carefully remove logs without moving heater base.
  • Page 12 – Correct all leaks at once.; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Figure 14 - Gas Connection; WARNING: Test all gas piping and connections,; Pressure Testing gas Supply Piping system; CHECKING GAS CONNECTIONS; CAUTION: Avoid damage to regulator. Hold gas
  • Page 13 – WARNING: Failure to position the parts in accor-; INSTALLING LOGS
  • Page 14 – • If fireplace has glass doors, never operate this; LIGHTING; OPERATING HEATER; WARNING: If you do not follow these instructions; FOR YOUR SAFETY
  • Page 15 – WARNING: Do not operate heater between PILOT; WARNING: Damper handle will be hot if heater has
  • Page 16 – THERMOSTAT MODELS; Shutting Off Heater; Shutting Off Burners Only (pilot stays lit)
  • Page 17 – CAUTION: Do not try to adjust heating levels by; Figure 25 - Control Knob and Ignitor Button Location; Selecting the HI setting with the control knob will cause
  • Page 18 – INSPECTING BURNERS; PILOT FLAME PATTERN; BURNER PRIMARY AIR HOLES; WARNING: Turn off heater and let cool before
  • Page 19 – CLEANING AND MAINTENANCE; Figure 29 - Injector Holder On Outlet Burner Tube; SPECIFICATIONS
  • Page 20 – WARNING: Turn off heater; POSSIBLE CAUSE; TROUBLESHOOTING
  • Page 21 – OBSERVED PROBLEM; REMEDY
  • Page 22 – IMPORTANT
  • Page 23 – OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB; For Masonry and Factory-Built Metal Fireplace; Do not remove the screw. Make sure you tighten the; Figure 32 - Adhesive-backed Mounting Clip
  • Page 24 – ILLUSTRATED PARTS BREAKDOWN
  • Page 25 – PARTS LIST
  • Page 28 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; PARTS UNDER WARRANTY
  • Page 29 – • ACCESSORIES; OWNER'S REGISTRATION FORM
  • Page 30 – Postage; T APE
  • Page 31 – NOTES
  • Page 32 – NOT A UPC; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY
Loading the manual

UNVENTED (VENT-FREE)
GAS LOG HEATER

OWNER’S OPERATION AND
INSTALLATION MANUAL

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

n e i g h b o r ’ s p h o n e . F o l l o w t h e g a s
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or
the gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in a
listed ventless firebox enclosure. It is de-
sign-certified for these installations in ac-
cordance with ANSI Z21.11.2. Exception:
Do not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should not
be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to

Air for Combustion and Ventilation section on page 4 of this manual.

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Variable Manually-Controlled Models Also Design-Certified As Vented Decorative Appliances

24" Variable Manually-Controlled Models

LSL3124N and LSL3124P

Echo Valley Oak Log Design

24" Variable Thermostatically-Controlled Models

CDL3924NT and CDL3924PT

Meadowbrook Oak Log Design

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WARNING: Do not allow fans to blow directly into; SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls; TABLE OF CONTENTS

111347-01B F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flamepatterns. Ceiling fans ...

Page 3 - Continued; LOCAL CODES; CAUTION: Do not remove the data plates from the

111347-01B F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION Continued 1. This appliance is only for use with the type of gas indicated onthe rating plate. This applia...

Page 4 - WARNING: This heater shall not be installed in a; PRODUCT FEATURES; OPERATION; PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Meadowbrook Oak Logs with Thermostat Control

111347-01B F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 AIR FOR COMBUSTION ANDVENTILATION Today’s homes are built more energy efficient than ever. New mate-rials, increased insulation...

Other Desa Models