Desa LDL3930PR - Manual

Desa LDL3930PR

Desa LDL3930PR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – WARNING: Do not allow fans to blow directly into; TABLE OF CONTENTS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls
  • Page 3 – Continued; SAFETY INFORMATION; LOCAL CODES; CAUTION: Do not remove the data plates from the
  • Page 4 – Unusually Tight Construction; PRODUCT FEATURES; OPERATION; PRODUCT IDENTIFICATION; Figure 1 - Product Identification
  • Page 5 – AIR FOR COMBUSTION AND VENTILATION; Determining Fresh-Air Flow For; Confined and Unconfined Space; per kw) of the aggregate input rating; WARNING: If the area in which the heater may be
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors
  • Page 7 – Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; INSTALLATION; LOG SIZING REQUIREMENTS
  • Page 8 – Figure 4 - Minimum Clearance for Combustible to Wall; *Minimum 16 inches from Side Wall; Noncombustible; Noncombustible material OK.; Minimum Noncombustible Material Clearances; If Not Using Mantel; Installing Damper; If Using Mantel
  • Page 9 – Determining Minimum Mantel Clearance; Figure 6 - Minimum Mantel Clearances Without Using Hood; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain
  • Page 10 – Figure 11 - Attaching Flexible Gas Hose to Heater; Area of Various Standard; Chimney; WARNING: You must secure this heater to fire-; Installation Items Needed; Figure 10 - Attaching Damper Clamp
  • Page 11 – Figure 12 - Attaching Heater to Fireplace Floor; Installing Batteries in Receiver; Figure 14 - Installing Batteries in Remote Control; Installing Battery into Remote; Figure 13 - Installing Batteries in Receiver; Cover
  • Page 12 – Pipe Nipple Cap Tee Joint; Figure 16 - Gas Connection; Sediment Trap; Figure 15 - External Regulator With Vent Pointing Down; Install equipment shutoff valve in an accessible; CONNECTING TO GAS SUPPLY
  • Page 13 – WARNING: Test all gas piping and connections,; CHECKING GAS CONNECTIONS; Figure 17 - Equipment Shutoff Valve; Open; Pressure Testing gas Supply Piping system; Correct all leaks at once.; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Equipment Shutoff Valve
  • Page 14 – WARNING: Failure to position the parts in accor-; INSTALLING LOGS; Cutout
  • Page 15 – OPERATING HEATER; FOR YOUR SAFETY; Control Cover Log; Control Knob
  • Page 16 – Shutting Off Heater; CAUTION: Do not try to adjust heating levels by; Pilot Burner; Clock Icon; Figure 29 - Remote Control; LCD Display
  • Page 17 – INSPECTING BURNERS; PILOT FLAME PATTERN; BURNER PRIMARY AIR HOLES
  • Page 18 – CLEANING AND MAINTENANCE; Burner Tube; Figure 32 - Injector Holder On Outlet Burner Tube; LOGS; • If you remove logs for cleaning, refer to Installing Logs, page 14,; MAIN BURNER; WARNING: Turn off heater and let cool before; Remove control cover log and front log.
  • Page 19 – WARNING: Turn off heater; POSSIBLE CAUSE; TROUBLESHOOTING
  • Page 20 – OBSERVED PROBLEM; nance, page 18) or replace burner orifice; Inlet gas pressure is too low
  • Page 21 – IMPORTANT; REMEDY
  • Page 22 – ILLUSTRATED PARTS BREAKDOWN
  • Page 23 – PARTS LIST; KEY
  • Page 24 – SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; PARTS UNDER WARRANTY; WIRING DIAGRAM; Black
  • Page 25 – • ACCESSORIES; OWNER'S REGISTRATION FORM
  • Page 26 – Postage; T APE
  • Page 27 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010
  • Page 28 – NOT A UPC; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:
Loading the manual

UNVENTED (VENT-FREE)
GAS LOG HEATER

OWNER’S OPERATION AND
INSTALLATION MANUAL

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

n e i g h b o r ’ s p h o n e . F o l l o w t h e g a s
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or
the gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in a
listed ventless firebox enclosure. It is de-
sign-certified for these installations in ac-
cordance with ANSI Z21.11.2. Exception:
Do not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should not
be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to

Air for Combustion and Ventilation section on page 4 of this manual.

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Also Design-Certified As Vented Decorative Appliances

24" and 30" Remote-Ready Models

MODELS

LDL3924NR

LDL3924PR

LDL3930NR

LDL3930PR

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WARNING: Do not allow fans to blow directly into; TABLE OF CONTENTS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its controls

111515-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flamepatterns. Ceiling fans ...

Page 3 - Continued; SAFETY INFORMATION; LOCAL CODES; CAUTION: Do not remove the data plates from the

111515-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION Continued 1. This appliance is only for use with the type of gas indicated onthe rating plate. This applia...

Page 4 - Unusually Tight Construction; PRODUCT FEATURES; OPERATION; PRODUCT IDENTIFICATION; Figure 1 - Product Identification

111515-01C F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 AIR FOR COMBUSTION ANDVENTILATION Today’s homes are built more energy efficient than ever. New mate-rials, increased insulation...

Other Desa Models