Desa FVFM27NR - Manual

Desa FVFM27NR

Desa FVFM27NR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
  • Page 3 – OWNER’S MANUAL; Figure 1 - Product Identification; OPERATION; UNPACKING; CAUTION: Do not remove the; LOCAL CODES; Control Knob
  • Page 4 – Unusually Tight Construction; per
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
  • Page 6 – Figure 3 - Ventilation Air from Outdoors; VENTILATION AIR; Ventilation Air From Outdoors; Do not provide openings for
  • Page 7 – INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace
  • Page 8 – If using a mantel, proceed to If Using; Noncombustible material OK.
  • Page 9 – Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; FLOOR CLEARANCES; A. If installing appliance on the floor level,; Non-Combustible Material; flue damper open
  • Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Damper; Manufactured Fireplace
  • Page 11 – WARNING: Never connect; Fitting; CAUTION: Avoid damage to; Figure 13 - Gas Connection; * Minimum inlet pressure for purpose of input adjustment.; Gas Control
  • Page 12 – Figure 14 - Manual Shutoff Valve; Open; Figure 15 - Checking Gas Joints; Gas Meter; WARNING: Never use an; Correct all leaks at once.
  • Page 13 – INSTALLING LOGS; CAUTION: After installation; Make sure log
  • Page 14 – LIGHTING; • If fireplace has glass doors,
  • Page 15 – Ignitor Electrode; CAUTION: Do not try to adjust; Shutting Off Heater; IMPORTANT; GHRCT Series Operation:; Lighting; Thermostat Control Operation
  • Page 16 – Figure 24 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; The hand-held remote
  • Page 17 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
  • Page 18 – OBSERVED PROBLEM; nance, page 20) or replace burner orifice
  • Page 19 – Operating heater where impurities in air exist may create odors.
  • Page 20 – LOGS; SPECIFICATIONS; When Gas Pressure Is Too Low; Figure 27 - Pilot Inlet Air Hole; MAIN BURNER
  • Page 21 – PARTS UNDER WARRANTY; ACCESSORIES; FIREPLACE HOOD; WIRING DIAGRAM; Note
  • Page 23 – PARTS LIST; Part Number
  • Page 24 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; LIMITED WARRANTY; For information about this warranty write:
Loading the manual

UNVENTED (VENT-FREE) NATURAL GAS

LOG HEATER

®

Patent Pending

Multi-Sided

Log Design

FVFM27NR

(Millivolt) Remote

Control Ready Model

ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE

OWNER’S OPERATION AND INSTALLATION MANUAL

Save this manual for future reference.

PIL

O T

O

F

F

O

N

LO

REMOTE

OFF

HI

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.

— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do
not use any phone in your building.

Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.

If you cannot reach your gas supplier,
call the fire department.

— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.

WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational pro-
cedures. For assistance or additional
information consult a qualified installer,
service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to

Air for Combustion and Ventilation section on page 4 of this manual.

WARNING: This appliance is for in-
stallation only in a solid-fuel burning
masonry UL127 factory-built fireplace,
or in an approved ventless firebox. It
is design-certified for these installa-
tions in accordance with ANS Z21.11.2.
Exceptions: Do not install this appli-
ance in a factory-built fireplace that
includes instructions stating it has
not been tested or should not be used
with unvented gas logs.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state
or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide

2 105223 UNVENTED NATURAL GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• shut off gas supply• do not try to light any appliance• do...

Page 3 - OWNER’S MANUAL; Figure 1 - Product Identification; OPERATION; UNPACKING; CAUTION: Do not remove the; LOCAL CODES; Control Knob

3 105223 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Product Identification PRODUCTFEATURES OPERATION This heater is clean burning. It requires nooutside venting. There is no heat loss out avent or up a chimney. Heat is generated byrealistic, dancing yellow flames. This heateris designed for ven...

Page 4 - Unusually Tight Construction; per

4 105223 UNVENTED NATURAL GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing ventilation...

Other Desa Models