Table of Contents:

  • Page 2 – DYNAVENT; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
  • Page 3 – OWNER’S MANUAL; LOCAL CODES; HOT SURFACE IGNITOR; SPECIFICATIONS
  • Page 4 – Minimum Clearances; door would block normal air flow; INSTALLATION; CHECK GAS TYPE; WARNING: Turn off electrical
  • Page 5 – Installing in Normal Frame Wall; Installing in Masonry Wall; INSTALLING THERMOSTAT; Mounting Thermostat to Furnace; WARNING: Unplug furnace
  • Page 6 – Note mounting; Locating Thermostat on Wall; Locate thermostat 4; HOT SPOTS; COLD SPOTS; Routing Thermostat Cable; above right side of furnace.
  • Page 7 – Feed thermostat wires from attic to; Mounting the Thermostat to Wall; Drill proper-sized holes for wall anchors.; Figure 7 - Mounting Thermostat to Wall
  • Page 8 – WARNING: Never use an open; Figure 13 - Location of Knockout Plug
  • Page 9 – CAUTION: Never connect heater directly to the propane/LP supply.; Providing Gas Piping to Furnace; Consult your local gas company for proper routing of the gas lines.; MINIMUM
  • Page 10 – Locate sediment trap where; Slab Floor Installation; Crawl Space Installation; Correct all leaks at once.
  • Page 11 – Figure 16 - Equipment Shutoff Valve; Performance Check; You may have removed fur-
  • Page 12 – WARNING: Do not operate; FOR YOUR SAFETY; WARNING: Always follow; Figure 18 - Equipment Shutoff Valve
  • Page 13 – CAUTION: Do not try to adjust; Blue flame with
  • Page 14 – WARNING: Keep furnace clear; CABINET; Air Passageways; • Use a vacuum cleaner or pressurized air; Exterior; • Use a soft cloth dampened with a mild; EXHAUST AND INTAKE VENTS
  • Page 15 – TROUBLESHOOTING; WARNING: Turn off and unplug furnace and let cool before servic-; All troubleshooting items are listed in; OBSERVED PROBLEM
  • Page 16 – Blower not operating; REMEDY; On initial operation of glo
  • Page 19 – WIRING DIAGRAMS; Use only original replacement parts.; PARTS UNDER WARRANTY
  • Page 20 – PARTS CENTRALS; When Gas Pressure Is Too Low; • glo-bar glows, but burner will not ignite; When Gas Quality Is Bad; • burner will not stay lit
  • Page 21 – KEY
  • Page 29 – NOTES
  • Page 30 – WARRANTY INFORMATION; KEEP THIS WARRANTY; INTERNATIONAL; NOT A UPC
Loading the manual

Save this manual for future reference.

SOLID STATE IGNITION

50 60 70 80 90

50 60 70 80 90

DYNAVENT

WINDOW WALL FURNACE

DIRECT-VENT PROPANE/LP GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

DNV25PB
DNV40PB

25,000 and 40,000 BTU/Hr “B” Model Furnaces

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

WARNING: Improper in-
stallation, adjustment,
alteration, service, or
maintenance can cause
injury or property dam-
age. Refer to this manual
for correct installation
and operational proce-
dures. For assistance or
additional information
consult a qualified in-
staller, service agency,
or the gas supplier.

WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.

— Installation and ser-
vice must be performed
by a qualified installer,
service agency, or the
gas supplier.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DYNAVENT; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide

2 201839 DIRECT-VENT PROPANE/LP GAS HEATER DYNAVENT ® 6. This furnace must have fresh air for properoperation. If not, poor fuel combustion andimproper venting of flue gases will result.Carbon monoxide poisoning from backed-up flue gases could occur. The State ofCalifornia lists carbon monoxide as a...

Page 3 - OWNER’S MANUAL; LOCAL CODES; HOT SURFACE IGNITOR; SPECIFICATIONS

3 201839 OWNER’S MANUAL LOCAL CODES UNPACKING 1. Remove furnace from carton. 2. Remove all protective packaging ap-plied to furnace for shipment. 3. Remove the following items from carton:• Hardware package containing four large screws, two small screws, andthermostat mounting plate • Hardware packa...

Page 4 - Minimum Clearances; door would block normal air flow; INSTALLATION; CHECK GAS TYPE; WARNING: Turn off electrical

4 201839 DIRECT-VENT PROPANE/LP GAS HEATER DYNAVENT ® 6" Minimum Adjacent Side Wall Ceiling Finished Floor, Carpet, Tile, etc. 12" Minimum 12" Minimum Figure 1 - Mounting Clearances as Viewedfrom Front of Furnace The clearance between the cabinet and thewall it passes through is 0 inches...

Other Desa Models