Table of Contents:

  • Page 2 – SAFETY INFORMATION; WARNINGS; DANGER: Carbon monoxide poisoning may lead; TABLE OF CONTENTS; Carbon Monoxide Poisoning:; WARNING: Any change to this log set or its
  • Page 3 – PRODUCT IDENTIFICATION; Continued; LOCAL CODES; UNPACKING; CAUTION: Do not remove the metal data plates; PRODUCT FEATURE; REMOTE READY SAFETY VALVE/PILOT
  • Page 4 – INSTALLATION; CHECK GAS TYPE; This vented appliance must be installed only in a solid-fuel; Figure 2 - Technical Information Charts
  • Page 5 – Masonry Fireplace; INSTALLING DAMPER CLAMP; WARNING: A qualified service person must con-; Installation Items Needed; • equipment shutoff valve; WARNING: Use pipe joint sealant that is resistant; Figure 4 - Gas Connection
  • Page 6 – WARNING: Test all gas piping and connections; CHECKING GAS CONNECTIONS; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; Figure 5 - Checking Gas Joints; HEARTH PAN INSTALLATION
  • Page 7 – Propane/LP Gas Conversion; Burner Inlet Fitting; Figure 8 - Remove Burner Inlet Fitting; . Rethread the valve and fitting assembly into the burner tube; Figure 9 - Burner Inlet Fittings with Injectors; Adjusting Regulator Pressure For Propane/LP Conversion
  • Page 8 – Generously apply soapy solution to all connections.; WARNING: Never check for gas leaks with; The burner design in-; ADDING PAN MATERIAL; Figure 12 - Installing Propane/LP Pilot Orifice; Changing Pilot Orifice; Replace and tighten the pilot line to the bracket.; REMOTE CONTROL OPTIONS; GHRC; Install a 9V battery into the hand-held transmitter.; Figure 13 - Connecting Wire Terminals; No Optional Accessories
  • Page 9 – Place the back log on the grate onto the grate steps (see Figure 15).; Arlington Round Oak Logs
  • Page 10 – LIGHTING INSTRUCTIONS; OPERATING APPLIANCE; FOR YOUR SAFETY READ; WARNING: If you do not follow these instructions; Figure 18 - Thermopile and Pilot; If Using Optional Hand-Held Remote or Wall Switch:
  • Page 11 – CURING LOGS; Shutting Off Appliance; OPTIONAL REMOTE OPERATION; Lighting Instructions,; GWMS2 WALL MOUNTED SWITCH
  • Page 12 – INSPECTING BURNERS; PILOT ASSEMBLY; Figure 19 - Correct Pilot Flame Pattern; BURNER FLAME PATTERN; REPLACEMENT PARTS; PARTS UNDER WARRANTY; Figure 20 - Locating Pilot Adjustment Screw
  • Page 13 – TROUBLESHOOTING; WARNING: Turn off log set and let cool before; POSSIBLE CAUSE
  • Page 14 – OBSERVED PROBLEM; nance, page 12) or replace pilot assembly
  • Page 15 – IMPORTANT
  • Page 16 – ILLUSTRATED PARTS BREAKDOWN
  • Page 17 – PARTS LIST
  • Page 18 – Kingston Split Oak Logs
  • Page 19 – KEY
  • Page 26 – MODELS CPVSA18R, AND CPVSA24R
  • Page 28 – ACCESSORIES; For all models. Use for firebox decoration only.; An attractive way to cover control knob and piezo ignitor.
  • Page 29 – OWNER'S REGISTRATION FORM
  • Page 30 – Postage; T APE
  • Page 31 – NOTES
  • Page 32 – WARRANTY INFORMATION; Model; LIMITED WARRANTY; NOT A UPC
Loading the manual

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any
other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

— Installation and service must be performed by a

qualified installer, service agency, or the gas supplier.

WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assis-
tance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.

WARNING: This appliance is for
installation only in a solid-fuel
burning masonry or UL127 factory-
built fireplace, constructed of non-
combustible material, and con-
nected to a working flue. (See page
4 for minimum flue opening.)

WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to the

National

Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

ANSI Z21.60a-2000

CSA 2.26a-2000

APPROVED

TM

Convertible from Natural

Gas to Propane/LP Gas

VANGUARD MODELS:

VVSA18R, VVSA24R, VVDA18R, VVDA24R and VVDA30R

FOR USE WITH LOG SETS:

Hanover Round Oak Log Models VSLR18 and VSLR24

Kingston Split Oak Log Models VDLCR18, VDLCR24 (Shown)
and VDLCR30

FMI MODELS:

FVSA18R, FVSA24R, FVDA18R, FVDA24R and FVDA30R

FOR USE WITH LOG SETS:

Arlington Round Oak Log Models FSLR18 and FSLR24

Manchester Split Oak Log Models FDLCR18, FDLCR24 and
FDLCR30

COMFORT GLOW MODELS:

Berkshire Oak Log Models CVDA18R, CVDA24R and
CVDA30R

Amherst Oak Log Models CPVSA18R and CPVSA24R

GAS LOG REMOTE READY
VENTED DECORATIVE APPLIANCE

OWNER'S OPERATION AND INSTALLATION MANUAL

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY INFORMATION; WARNINGS; DANGER: Carbon monoxide poisoning may lead; TABLE OF CONTENTS; Carbon Monoxide Poisoning:; WARNING: Any change to this log set or its

901273-01D 2 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION WARNING ICON G 001 WARNINGS IMPORTANT: Read this owner’s manual carefully andcompletely before trying to ass...

Page 3 - PRODUCT IDENTIFICATION; Continued; LOCAL CODES; UNPACKING; CAUTION: Do not remove the metal data plates; PRODUCT FEATURE; REMOTE READY SAFETY VALVE/PILOT

901273-01D 3 3 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m PRODUCT IDENTIFICATION Hearth Kit Model ________________________ Serial Number __________________________ Log Set Model _____...

Page 4 - INSTALLATION; CHECK GAS TYPE; This vented appliance must be installed only in a solid-fuel; Figure 2 - Technical Information Charts

901273-01D 4 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m INSTALLATION Flue Opening SpecificationsCheck Gas TypeVenting Specifications for Installation INSTALLATION CHECK GAS TYPE Use o...

Other Desa Models