- Page 2 – SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS
- Page 3 – Continued
- Page 4 – LOCAL CODES; CAUTION: Do not remove the data plates from the; Base Assembly; Figure 1 - Product Identification; PRODUCT IDENTIFICATION; Grate
- Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; PRODUCT FEATURES; PRODUCT FEATURES; AIR FOR COMBUSTION AND VENTILATION
- Page 6 – WARNING: If the area in which the heater may be
- Page 7 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors
- Page 8 – Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; LOG SIZING REQUIREMENTS; INSTALLATION
- Page 9 – Figure 4 - Minimum Clearance for Combustible to Wall; *Minimum 16 inches from Side Wall; Noncombustible; Noncombustible material OK.; Minimum Noncombustible Material Clearances; If Not Using Mantel; Installing Damper; If Using Mantel
- Page 10 – FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood
- Page 11 – When used as a vented heater, appliance must be installed; Area of Various Standard; Chimney; WARNING: You must secure this heater to fire-; Make sure the heater burners are level. If heater is; Installation Items Needed; Hold gas fitting with wrench when connecting; Figure 10 - Attaching Damper Clamp; Damper; Damper Clamp; Figure 11 - Attaching Flexible Gas Hose to Heater; Fitting
- Page 12 – WARNING: A qualified service person must con-; WARNING: For natural gas, never connect heater; Locate two masonry screws in hardware package.; CONNECTING TO GAS SUPPLY
- Page 13 – Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; Figure 13 - External Regulator With Vent Pointing Down
- Page 14 – WARNING: Test all gas piping and connections,; Pressure Testing gas Supply Piping system; Correct all leaks at once.; CHECKING GAS CONNECTIONS; Figure 16 - Equipment Shutoff Valve; Equipment Shutoff Valve; Pressure Testing Heater Gas Connections; Make sure control knobs of heater are in the OFF position.; Gas Meter
- Page 15 – WARNING: Failure to position the parts in accor-
- Page 17 – OPERATING HEATER; WARNING: If you do not follow these instructions; THERMOSTAT-CONTROLLED MODELS
- Page 18 – WARNING: Damper handle will be hot if heater has; CAUTION: Do not try to adjust heating levels by; Shutting Off Heater
- Page 19 – FOR YOUR SAFETY; • If fireplace has glass doors, never operate this; LIGHTING
- Page 20 – Shutting Off Burners Only (pilot stays lit); All remote control accessories must be purchased sepa-
- Page 21 – TO LOCK; Manual Mode; Auto Shutoff Feature
- Page 22 – WARNING: If yellow tipping occurs, your heater; INSPECTING BURNERS; PILOT FLAME PATTERN; Figure 39 - Correct Burner Flame Patterns
- Page 23 – WARNING: Turn off heater and let cool before; CLEANING AND MAINTENANCE; Figure 41 - Injector Holder On Outlet Burner Tube - Rear Burner; Blow air through the ports/slots and holes in the burners.; WARNING: Failure to keep the primary air; LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages
- Page 24 – WARNING: Turn off heater; POSSIBLE CAUSE; TROUBLESHOOTING
- Page 25 – OBSERVED PROBLEM; nance, page 23) or replace burner orifice
- Page 26 – IMPORTANT; REMEDY
- Page 27 – Do not force or bend the thermostat sensing; Figure 45 - Adhesive-backed Mounting Clip; OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB; Thermostat Sensing Bulb
- Page 28 – SPECIFICATIONS
- Page 29 – ILLUSTRATED PARTS BREAKDOWN; PART NUMBER FOR; Log Set
- Page 31 – PARTS LIST
- Page 34 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; Creates the sound of a real burning fire.
- Page 35 – OWNER'S REGISTRATION FORM
- Page 36 – Postage; T APE
- Page 37 – REPLACEMENT PARTS; PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE
- Page 38 – NOT A UPC
UNVENTED (VENT-FREE)
GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Remote-Ready Models Also Design-Certified As Vented Decorative Appliances
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
n e i g h b o r ’ s p h o n e . F o l l o w t h e g a s
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service, or maintenance can cause
injury or property damage. Refer to this
manual for correct installation and opera-
tional procedures. For assistance or addi-
tional information consult a qualified installer,
service agency, or the gas supplier.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry or
UL127 factory-built fireplace, or in an listed
ventless firebox enclosure. It is design-
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-built
fireplace that includes instructions stating
it has not been tested or should not be used
with unvented gas logs. For unmarked fac-
tory-built fireplaces, contact fireplace manu-
facturer if unsure of this application.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to
Air for Combustion and Ventilation section on page 5 of this manual.
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
24" and 30"Remote-Ready Models:
VRL24NR, VRL24PR, VRL30NR,
VRL30PR, CSG3924NR, CSG3924PR
CTB3924NR, CTB3924PR
CSG3930NR, CSG3930PR
24" and 30" Thermostat Models:
VRL24NT, VRL24PT, VRL30NT,
VRL30PT, CSG3924NT, CSG3924PT,
CTB3924NT, CTB3924PT
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
110021-01G F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approvedfor use with this heater. WARNING: T...
110021-01G F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 You must operate this heater with a fireplace screenin place. Make sure fireplace screen is closed beforerunning heater. Keep...
110021-01G F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, use the latest edition of T...