- Page 2 – Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
- Page 3 – OWNER’S MANUAL; UNPACKING; CAUTION: Do not remove the; LOCAL CODES; American National Standards Institute, Inc.
- Page 4 – Unusually Tight Construction; per
- Page 5 – DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 6 – Figure 3 - Ventilation Air from Outdoors; VENTILATION AIR; Ventilation Air From Outdoors; Do not provide openings for
- Page 7 – INSTALLATION; CHECK GAS TYPE; This vented appliance must be in-; NG; Figure 4 - Technical Information Charts
- Page 8 – Masonry Fireplace; WARNING: Never use an; Installation Items Needed; Figure 9 - Gas Connection
- Page 9 – Figure 7 - Checking Gas Joints; Kit Assembly; The following instructions apply to; Correct all leaks at once.; Installation and Gas Connection; Figure 9 - Installing Burner; WARNING: You must use a; Natural Gas Installation; Figure 10 - Connecting Gas to Appliance
- Page 10 – Push the control rod extension onto the; Propane/LP Gas Conversion; Burner Inlet Fitting; Figure 16 - Remove Burner Inlet Fitting; Changing Pilot Orifice; . Follow steps 1 through 12 under Natu-
- Page 11 – WARNING: Never check for; The burner design; Logs may chip if; Berkshire Split Oak Logs
- Page 12 – Flame Adjustment; Figure 21 - Ignitor and Control Knob; WARNING: Keep flue open
- Page 13 – TROUBLESHOOTING; WARNING: Turn off log set; POSSIBLE CAUSE; All troubleshooting items are listed in; TO TURN OFF GAS; Shutting Off Appliance; Press in and turn control clockwise
- Page 14 – IMPORTANT; OBSERVED PROBLEM
- Page 15 – nance, page 20) or replace pilot assembly
- Page 16 – Amherst Round Oak Logs
- Page 17 – PARTS LIST; KEY
- Page 20 – ACCESSORIES; PARTS UNDER WARRANTY
- Page 21 – PARTS CENTRALS
- Page 22 – NOTES
- Page 24 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; INTERNATIONAL; NOT A UPC
NATURAL GAS LOG
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency, or the
gas supplier.
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational
procedures. For assistance or
additional information consult
a qualified installer, service
agency, or the gas supplier.
WARNING: This appliance is
for installation only in a solid-
fuel burning masonry or UL127
factory-built fireplace, con-
structed of noncombustible
material, and connected to a
working flue. (See page 7 for
minimum flue opening.)
WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
VENTED DECORATIVE APPLIANCES
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference.
RADCO Burner
Models CVSR18,
CVSR24, CPVSR18,
CPVSR24, CVDR18,
CVDR24, and CVDR30
RGA 2-72
APPROVED
TESTED AND
LISTED BY
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 901048 FOR VENTED NATURAL GAS LOGS RADCO BURNERS 1. This appliance, as supplied, is only foruse with the type of gas indicated onthe rating plate. This appliance is con-vertible for use with propane/LP, usingthe GA9000 or GA9100 pilot kit. SAFETYINFORMATION Carbon Monoxide Poisoning: Early signs o...
3 901048 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Product Identification (VVDR24 Shown) OPTIONALPRODUCTFEATURES ON/OFF SAFETY VALVE/PILOT KIT AND PROPANE/LPCONVERSION An optional valve/safety pilot kit with apiezo ignitor is available for this appliance.This system requires no matches, batter...
4 901048 FOR VENTED NATURAL GAS LOGS RADCO BURNERS PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventila-tion. All spaces in homes fall into one of the threefollowing ventilation classifications: 1. Unusu...