Desa CLD3924NT - Manual
Desa CLD3924NT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – UNVENTED NATURAL GAS LOG HEATER; DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to
- Page 3 – OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; OPERATION; WARNING: Do not remove; Do not pick up
- Page 4 – Unusually Tight Construction; per
- Page 5 – Determining if You Have a Confined or Unconfined Space
- Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building; VENTILATION AIR
- Page 7 – INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace
- Page 8 – If using a mantel, proceed to If Using
- Page 9 – Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; Figure 7 - Minimum Mantel Clearances When Using Hood; flue damper open; FLOOR CLEARANCES; A. If installing appliance on the floor level,
- Page 10 – Figure 10 - Attaching Damper Clamp; Installation Items Needed; Manufactured Fireplace
- Page 11 – CAUTION: Avoid damage to; Figure 13 - Gas Connection; • manual shutoff valve *; WARNING: Never connect
- Page 12 – Figure 14 - Manual Shutoff Valve; Figure 15 - Checking Gas Joints; WARNING: Never use an open; Correct all leaks at once.
- Page 13 – WARNING: Failure to position; Figure 16 - Installing Back Log; CAUTION: After installation
- Page 15 – CAUTION: After installation and
- Page 16 – WARNING: Do not operate; WARNING: Damper handle
- Page 17 – Shutting Off Heater; CAUTION: Do not try to adjust
- Page 18 – • turn heater off (see To Turn Off Gas to; Figure 34 - Correct Pilot Flame Pattern; Selecting the Hi setting with the
- Page 19 – WARNING: Turn off heater; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER; • Use a vacuum cleaner or small, soft; Figure 37 - Pilot Inlet Air Hole
- Page 20 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 21 – OBSERVED PROBLEM; nance, page 19) or replace burner orifice
- Page 22 – IMPORTANT
- Page 23 – Do not remove the screw. Make
- Page 24 – SPECIFICATIONS; When Gas Pressure Is Too Low; PARTS UNDER WARRANTY
- Page 25 – ACCESSORIES; FIREPLACE HOOD; PARTS CENTRAL
- Page 27 – PARTS LIST; KEY
- Page 31 – PARTS AVAILABLE — NOT SHOWN
- Page 34 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; INTERNATIONAL; NOT A UPC
Save this manual for future reference.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational proce-
dures. For assistance or additional in-
formation consult a qualified installer,
service agency, or the gas supplier.
18" and 24" Variable
Manually-Controlled Models
®
ROYAL ENGLISH OAK, BILTMORE SPLIT OAK,
AND WINCHESTER OAK UNVENTED
(VENT-FREE) NATURAL GAS LOG HEATER
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
(Winchester Oak Model Shown)
24" and 30" Thermostatically-
Controlled Models
CLD3924NT
CCL3930NT(A)
CGS2718N
CGS3124N
CLD3018N
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
WARNING: This appliance is for in-
stallation only in a solid-fuel burning
masonry or UL127 factory-built fire-
place, or in an approved ventless
firebox. It is design-certified for these
installations in accordance with ANS
Z21.11.2.
Exception: Do not install this appli-
ance in a factory-built fireplace that
includes instructions stating it has
not been tested or should not be
used with unvented gas logs.
VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED
AS VENTED DECORATIVE APPLIANCES
OWNER’S OPERATION AND INSTALLATION MANUAL
Patent
Pending
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 104385 UNVENTED NATURAL GAS LOG HEATER CGS2718N, CGS3124N, CLD3018N,CLD3924NT, and CCL3930NT(A) SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re-semble the flu, with headaches, dizziness,or nausea. If you ...
3 104385 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Yellow Flame Vent-Free Gas Log Heater Shown (Logs May Vary by Model) LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1, also known ...
4 104385 UNVENTED NATURAL GAS LOG HEATER CGS2718N, CGS3124N, CLD3018N,CLD3924NT, and CCL3930NT(A) AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweat...