Desa CLD3018PT - Manual
Desa CLD3018PT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS
- Page 3 – Continued; PRODUCT IDENTIFICATION
- Page 4 – LOCAL CODES; Where listed vented decorative logs are required, thermostat; PRODUCT FEATURES; OPERATION; UNPACKING; CAUTION: Do not remove the data plates from the; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; WARNING: This heater shall not be installed in a
- Page 5 – AIR FOR COMBUSTION AND VENTILATION; Confined Space and Unconfined Space; per kw) of the aggregate input rating
- Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors; INSTALLATION; WARNING: A qualified service person must in-
- Page 7 – CHECK GAS TYPE; LOG SIZING REQUIREMENTS; MINIMUM FIREPLACE; Figure 4 - Minimum Clearance for Combustible to Wall
- Page 8 – Minimum Noncombustible Material Clearances; If Not Using Mantel; If using a mantel, proceed to If Using Mantel. If not using a; If Using Mantel; If you cannot meet these minimum clearances, you; Installing Damper; Noncombustible material okay.
- Page 9 – Determining Minimum Mantel Clearance; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood; Figure 7 - Minimum Mantel Clearances When Using Hood
- Page 10 – Area of Various Standard; Figure 10 - Attaching Damper Clamp; INSTALLING HEATER BASE ASSEMBLY; Installation Items Needed
- Page 11 – Remove heater base from fireplace.; Figure 12 - Attaching Base Assembly to Fireplace Floor; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Figure 13 - External Regulator With Vent Pointing Down; WARNING: For natural gas units, never connect
- Page 12 – Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; Figure 14 - Gas Connection; * Purchase the optional CSA design-certified equipment shutoff; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS
- Page 13 – Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Figure 15 - Equipment Shutoff Valve; WARNING: Failure to position the parts in accor-; Figure 18 - Installing Back Log
- Page 14 – Figure 19 - Installing Front Log
- Page 15 – OPERATING HEATER; WARNING: If you do not follow these instructions; FOR YOUR SAFETY READ
- Page 16 – OPERATING HEATER Manually-Controlled Models; LIGHTING; Figure 25 - Control Knob and Ignitor Button Location; VARIABLE CONTROL; Natural Gas
- Page 17 – OPERATING HEATER Thermostatically-Controlled Models; Shutting Off Heater; THERMOSTATICALLY-CONTROLLED; WARNING
- Page 18 – CAUTION: Do not try to adjust heating levels by; Figure 27 - Control Knob and Ignitor Button Location; Selecting the HI setting with the control knob will cause the; Shutting Off Burners Only (pilot stays lit)
- Page 19 – CLEANING AND MAINTENANCE; BURNER PRIMARY AIR HOLES; INSPECTING BURNERS; PILOT FLAME PATTERN; Figure 29 - Correct Pilot Flame Pattern; WARNING: Turn off heater and let cool before; Figure 31 - Injector Holder On Outlet Burner Tube; WARNING: Failure to keep the primary air
- Page 20 – Blow air into the primary air holes on the injector holder.; Figure 32 - Pilot Inlet Air Hole; • If you remove logs for cleaning, refer to Installing Logs, page; TECHNICAL SERVICE; When Gas Pressure Is Too Low; REPLACEMENT PARTS; Use only original replacement parts. This will protect your
- Page 21 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 22 – OBSERVED PROBLEM; nance, page 19) or replace burner orifice
- Page 23 – IMPORTANT
- Page 24 – Do not remove the screw. Make sure you tighten the; OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
- Page 25 – SPECIFICATIONS
- Page 26 – ILLUSTRATED PARTS BREAKDOWN
- Page 27 – PARTS LIST; PART NUMBER
- Page 29 – KEY
- Page 32 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; PARTS CENTRAL; FIREPLACE HOOD
- Page 33 – OWNER'S REGISTRATION FORM
- Page 34 – Postage; T APE
- Page 35 – NOTES
- Page 36 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; NOT A UPC
ROYAL ENGLISH OAK AND WINCHESTER OAK
UNVENTED (VENT-FREE) GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
18" and 24" Variable Manually-
Controlled Models
CGS2718P, CGS2718N
CGS3124P, CGS3124N
SGS3124P, SGS3124N
CLD3018PA, CLD3018NA
18" and 24" Thermostatically-
Controlled Models
CLD3018PT, CLD3018NT
CLD3924PTA, CLD3924NTA
(Winchester Oak Model Shown)
VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED
AS VENTED DECORATIVE APPLIANCES
Patent Pending
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance can
cause injury or property damage. Refer to
this manual for correct installation and op-
erational procedures. For assistance or ad-
ditional information consult a qualified in-
staller, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate
combustion and ventilation air must be pro-
vided. Refer to
Air for Combustion and Ven-
tilation section on page 4 of this manual.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: This appliance is for installation
only in a solid-fuel burning masonry or UL127
factory-built fireplace, or in a listed ventless
firebox enclosure. It is design-certified for these
installations in accordance with ANSI Z21.11.2.
Exception: Do not install this appliance in a
factory-built fireplace that includes instructions
stating it has not been tested or should not be
used with unvented gas logs.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
107068-01H F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poi...
107068-01H F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 1. This appliance is only for use with the type of gas indicated onthe rating plate. This appliance is not convertible for us...
107068-01H F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODESUNPACKINGPRODUCT FEATURESAIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation LOCAL CODES Install and u...