Desa CLD3018NA - Manual

Desa CLD3018NA

Desa CLD3018NA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its; TABLE OF CONTENTS
  • Page 3 – Continued; PRODUCT IDENTIFICATION
  • Page 4 – LOCAL CODES; Where listed vented decorative logs are required, thermostat; PRODUCT FEATURES; OPERATION; UNPACKING; CAUTION: Do not remove the metal data plates; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; WARNING: This heater shall not be installed in a
  • Page 5 – AIR FOR COMBUSTION AND VENTILATION; Confined Space and Unconfined Space; per kw) of the aggregate input rating
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors; INSTALLATION; WARNING: A qualified service person must in-
  • Page 7 – Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; LOG SIZING REQUIREMENTS; MINIMUM FIREPLACE; A. Clearances from the side of the fireplace opening to any com-; Figure 4 - Minimum Clearance for Combustible to Wall
  • Page 8 – Minimum Noncombustible Material Clearances; If Not Using Mantel; If using a mantel, proceed to If Using Mantel. If not using a; If Using Mantel; If you cannot meet these minimum clearances, you; Installing Damper; Noncombustible material okay.
  • Page 9 – Determining Minimum Mantel Clearance; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood; Figure 7 - Minimum Mantel Clearances When Using Hood
  • Page 10 – Area of Various Standard; Figure 10 - Attaching Damper Clamp; INSTALLING HEATER BASE ASSEMBLY; Installation Items Needed
  • Page 11 – Remove heater base from fireplace.; Figure 12 - Attaching Base Assembly to Fireplace Floor; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Figure 13 - External Regulator With Vent Pointing Down; WARNING: For natural gas units, never connect
  • Page 12 – Install equipment shutoff valve in an accessible; CAUTION: Use pipe joint sealant that is resistant; Figure 14 - Gas Connection; * Purchase the optional CSA design-certified equipment shutoff; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS
  • Page 13 – Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Figure 15 - Equipment Shutoff Valve; WARNING: Failure to position the parts in accor-; Figure 18 - Installing Back Log
  • Page 14 – Figure 19 - Installing Front Log
  • Page 15 – OPERATING HEATER; WARNING: If you do not follow these instructions; FOR YOUR SAFETY READ
  • Page 16 – OPERATING HEATER Manually-Controlled Models; LIGHTING INSTRUCTIONS; Figure 25 - Control Knob and Ignitor Button Location; VARIABLE CONTROL OPERATION; Natural Gas
  • Page 17 – OPERATING HEATER Thermostatically-Controlled Models; Shutting Off Heater; THERMOSTATICALLY-CONTROLLED; WARNING
  • Page 18 – CAUTION: Do not try to adjust heating levels by; Figure 27 - Control Knob and Ignitor Button Location; TO TURN OFF GAS TO APPLIANCE; Shutting Off Burners Only (pilot stays lit); THERMOSTAT CONTROL OPERATION; Selecting the HI setting with the control knob will cause; MANUAL LIGHTING PROCEDURE
  • Page 19 – CLEANING AND MAINTENANCE; BURNER PRIMARY AIR HOLES; INSPECTING BURNERS; Check pilot flame pattern and burner flame patterns often.; PILOT FLAME PATTERN; If pilot flame pattern is incorrect, as shown in Figure 30; Figure 29 - Correct Pilot Flame Pattern; WARNING: Turn off heater and let cool before; • Use a vacuum cleaner or small, soft bristled brush to clean.; Figure 31 - Injector Holder On Outlet Burner Tube
  • Page 20 – Figure 32 - Pilot Inlet Air Hole; TECHNICAL SERVICE; When Gas Pressure Is Too Low; REPLACEMENT PARTS
  • Page 21 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
  • Page 22 – OBSERVED PROBLEM; nance, page 19) or replace burner orifice
  • Page 23 – IMPORTANT
  • Page 24 – Do not remove the screw. Make sure you tighten the; OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
  • Page 25 – SPECIFICATIONS
  • Page 26 – ILLUSTRATED PARTS BREAKDOWN
  • Page 27 – PARTS LIST; KEY
  • Page 32 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; PARTS CENTRAL; FIREPLACE HOOD
  • Page 33 – OWNER'S REGISTRATION FORM
  • Page 34 – Postage
  • Page 35 – NOTES
  • Page 36 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; NOT A UPC
Loading the manual

ROYAL ENGLISH OAK AND WINCHESTER OAK
UNVENTED (VENT-FREE) GAS LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

18" and 24" Variable Manually-

Controlled Models

CGS2718P, CGS2718N
CGS3124P, CGS3124N

CLD3018PA, CLD3018NA

24" Thermostatically-Controlled Models

CLD3924PTA, CLD3924NTA

(Winchester Oak Model Shown)

VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED

AS VENTED DECORATIVE APPLIANCES

Patent Pending

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

n e i g h b o r ’ s p h o n e . F o l l o w t h e g a s
supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or the
gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.

WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) from the room
in which it is installed. Provisions for ad-
equate combustion and ventilation air
must be provided. Refer to

Air for Com-

bustion and Ventilation section on page 4
of this manual.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design-
certified for these installations in accor-
dance with ANSI Z21.11.2.
Exception: Do not install this appliance in a
factory-built fireplace that includes instruc-
tions stating it has not been tested or should
not be used with unvented gas logs.

This appliance may be installed in an aftermar-
ket,* permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile)
home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY INFORMATION; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; WARNING: Any change to this heater or its; TABLE OF CONTENTS

107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoni...

Page 3 - Continued; PRODUCT IDENTIFICATION

107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 1. This appliance is only for use with the type of gas indicated onthe rating plate. This appliance is not convertible for use wi...

Page 4 - LOCAL CODES; Where listed vented decorative logs are required, thermostat; PRODUCT FEATURES; OPERATION; UNPACKING; CAUTION: Do not remove the metal data plates; PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; WARNING: This heater shall not be installed in a

107068 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODESUNPACKINGPRODUCT FEATURESAIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation LOCAL CODES Install and use h...

Other Desa Models