- Page 2 – UNPACKING; Carbon Monoxide Poisoning; WARNINGS; DANGER: Carbon monoxide
- Page 3 – OWNER’S MANUAL; Confined and Unconfined Space; per; Unusually Tight Construction
- Page 4 – WARNING: If the area in; Includes the room in which you; Total =; the space can support); VENTILATION AIR
- Page 5 – Figure 2 - Ventilation Air from Inside Building; Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings
- Page 6 – Figure 4 - Mounting Clearances As Viewed From Front of Heater; CHECK GAS TYPE
- Page 7 – Mounting Bracket; Figure 5 - Mounting Bracket Location; Removing Front Panel Of Heater; Figure 6 - Removing Front Panel Of Heater; Attaching to wall stud; Marking Screw Locations; WARNING: Maintain minimum; Attaching to wall stud method; For attaching mounting bracket to wall studs; Attaching to wall anchor method; Fold wall anchor as shown in Figure 8.; Only mark last hole on each end; Attaching to wall stud:; Figure 8 - Folding Anchor
- Page 8 – CAUTION: Never connect; Mark screw locations on wall.; Do not replace front panel at this
- Page 9 – Figure 13 - Gas Connection; Hold pressure regulator; WARNING: Never use an open; Figure 14 - Manual Shutoff Valve; Correct all leaks at once.
- Page 10 – Note; Figure 15 - Checking Gas Joints
- Page 11 – Turn control knob counterclockwise; : Both HIGH and LOW are; Shutting Off Heater; to the OFF position.; Figure 18 - Correct Pilot Flame Pattern; Figure 20 - Correct Burner Flame Pattern; WARNING: If yellow tipping; • turn heater off (see To Turn Off Gas to
- Page 12 – TROUBLESHOOTING; WARNING: Turn off and; OBSERVED PROBLEM
- Page 13 – REMEDY
- Page 14 – POSSIBLE CAUSE; IMPORTANT; OBSERVED PROBLEM
- Page 15 – SPECIFICATIONS; When gas pressure is too low; SERVICE HINTS; WARNING: Turn off heater; CABINET; Air Passageways
- Page 16 – PARTS CENTRALS
- Page 17 – ACCESSORIES; FLOOR MOUNTING STAND
- Page 19 – PARTS LIST; KEY
- Page 22 – NOTES
- Page 24 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS: CGP20, CGP20L, AND RP30D
BLUE-FLAME VENT-FREE
PROPANE/LP GAS HEATER
®
Save this manual for future reference.
RP30D
CGP20
CGP20L
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is
permitted after the manufactured (mobile) home is sited)
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• I m m e d i a t e l y c a l l y o u r g a s s u p p l i e r f r o m a
neighbor’s phone. Follow the gas supplier’s in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Air for
Combustion and Ventilation sec-
tion on page 3 of this manual.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 103569 VENT-FREE PROPANE/LP GAS HEATER BLUE-FLAME CGP20, CGP20L AND RP30D PRODUCTFEATURES Safety Device This heater has a pilot with an OxygenDepletion Sensor Shutoff System (ODS).The ODS/pilot is a required feature for vent-free heaters. The ODS/pilot shuts off theheater if there is not enough fr...
3 103569 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Vent-Free Propane/LP Gas Heater Ignitor Button Control Knob HeaterCabinet FrontPanel Heat Shield(RP30D) orGlass Panel(CGP20[L]) GrillGuard AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials...
4 103569 VENT-FREE PROPANE/LP GAS HEATER BLUE-FLAME CGP20, CGP20L AND RP30D Continued WARNING: If the area in which the heater may be oper-ated is smaller than that definedas an unconfined space, provideadequate combustion and venti-lation air by one of the methodsdescribed in the National Fuel Gas ...