Desa CGP11A - Manual

Desa CGP11A

Desa CGP11A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – CONTENTS; SECTION; WARNINGS; Read this owner’s manual carefully and completely; DANGER; Carbon monoxide poisoning may lead to death!; Early signs of carbon monoxide poisoning; Propane Gas; Safety Information continues on next page
  • Page 3 – Continued
  • Page 4 – American National Standards Institute, Inc.
  • Page 5 – WARNING; PRODUCING ADEQUATE VENTILATION; Unusually Tight Construction; and; Unconfined Space
  • Page 6 – You must provide additional ventilation air in a confined space.; DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
  • Page 7 – Ventilation Air From Inside Building; Figure 2 - Ventilation Air from Inside Building
  • Page 8 – Ventilation Air From Outdoors; Figure 3 - Ventilation Air from Outdoors
  • Page 9 – NOTICE; CHECK GAS TYPE; Before installing heater, make sure you have the items below:; If you install the heater in a home garage; LOCATING HEATER; This heater is designed to be mounted on a wall.; Never install the heater; CAUTION
  • Page 10 – INSTALLING HEATER TO WALL; Marking Screw Locations; Determine where you will locate heater.; JOINING WALL; For convenience and efficiency, install heater; INSTALLING
  • Page 11 – Installing Two Mounting Screws; package is provided with heater.; Attaching to wall stud method
  • Page 12 – Placing Heater On Mounting Screws; are in small portion of slots.; Figure 11 - Installing Bottom Mounting Screw; Removing Front Panel Of Heater; Figure 10 - Removing Front Panel Of Heater; Installing Bottom Mounting Screw
  • Page 13 – Figure 12 - External Regulator With Vent Pointing Down
  • Page 14 – Hold pressure regulator with wrench when connecting it to gas; Figure 13 - Gas Connection; PRESSURE TESTING GAS SUPPLY PIPING SYSTEM; Test Pressures In Excess Of 1/2 PSIG; Connecting to Gas Supply,
  • Page 15 – Test Pressures Equal To or Less Than 1/2 PSIG; propane supply tank valve.; PRESSURE TESTING HEATER GAS CONNECTIONS; internal joints for leaks.; CHECKING; Figure 15 - Checking Gas Joints; Figure 14 - Manual Shutoff Valve
  • Page 16 – FOR YOUR SAFETY READ BEFORE LIGHTING; Figure 16 - Control Knob In The OFF Position
  • Page 18 – TO SELECT HEATING LEVEL; Figure 18 - Burner Patterns; Slightly press in control knob and turn counterclockwise; Control; OPERATING
  • Page 19 – Check pilot flame pattern and burner flame pattern often.; PILOT FLAME PATTERN; Figure 19 - Correct Pilot Flame Pattern; Figure 20 - Incorrect Pilot Flame Pattern; If pilot flame pattern is incorrect, as shown in Figure 20; TO TURN OFF GAS TO APPLIANCE; Shutting Off Heater; to the OFF position.; to the PILOT position.; MANUAL LIGHTING PROCEDURE
  • Page 20 – If burner flame pattern is incorrect, as shown in Figure 22; Figure 22 - Incorrect Burner Flame Pattern; BURNER FLAME PATTERN; INSPECTING
  • Page 21 – Turn off heater and let cool before cleaning.; ODS/PILOT AND BURNER ORIFICE; Air Passageways; SHOOTING; REMEDY
  • Page 24 – TECHNICAL
  • Page 25 – SPECIFICATIONS; Parts Under Warranty; REPLACEMENT; When gas pressure is too low; SERVICE
  • Page 27 – HEATER EXPLODED VIEW
  • Page 28 – KEEP THIS WARRANTY; WARRANTY INFORMATION; LIMITED WARRANTY
Loading the manual

Save this manual for future reference.

VENT-FREE PROPANE GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Model: CGP11A

WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service

agency, or the gas supplier.

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS; SECTION; WARNINGS; Read this owner’s manual carefully and completely; DANGER; Carbon monoxide poisoning may lead to death!; Early signs of carbon monoxide poisoning; Propane Gas; Safety Information continues on next page

2 100846 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes .......................................................................

Page 3 - Continued

3 100846 SAFETY INFORMATION Continued WARNING ICON G 001 WARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. Use only propane gas. Do not convert heater to use different fuel type.2. Do not place propane supply tank(s) inside any structure. Locate propane suppl...

Page 4 - American National Standards Institute, Inc.

4 100846 PRODUCT IDENTIFICATION PRODUCT FEATURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS).The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shutsoff the heater if there is not enough fresh air. Piezo Ignition System This h...