  • Page 2 – NATURAL GAS HEATER; WARNINGS; WARNING: Any change to; Carbon Monoxide Poisoning:; Early signs of
  • Page 3 – OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.; SAFETY PILOT
  • Page 4 – Unusually Tight Construction
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
  • Page 6 – Figure 2 - Ventilation Air from Inside Building; Figure 3 - Ventilation Air from Outdoors; VENTILATION AIR; Ventilation Air From Outdoors; Do not provide openings for
  • Page 7 – INSTALLATION; Figure 5 - Mounting Screw Locations; Marking Screw Locations; LOCATING HEATER
  • Page 8 – Mark screw location on wall.; Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching to Wall Stud Method; For attaching mounting screw to wall stud; Attaching to Wall Anchor Method; Removing Front Panel of Heater; Figure 6 - Folding Anchor
  • Page 9 – Figure 12 - Gas Connection; Hold pressure regulator with; WARNING: Never connect
  • Page 10 – FOR YOUR SAFETY; Figure 13 - Equipment Shutoff Valve; Figure 14 - Checking Gas Joints; Correct all leaks at once.; WARNING: Never use an open
  • Page 11 – Control; Figure 17 - Burner Patterns; WARNING: When running; Shutting Off Heater; CAUTION: Do not try to adjust
  • Page 12 – WARNING: Turn off heater; Figure 20 - Correct Burner Flame Pattern; BURNER FLAME PATTERN; Figure 18 - Correct Pilot Flame Pattern; Figure 19 - Incorrect Pilot Flame Pattern; CABINET; Air Passageways; Figure 22 - Pilot Inlet Air Hole
  • Page 13 – TROUBLESHOOTING; OBSERVED PROBLEM; All troubleshooting items are listed in
  • Page 14 – REMEDY
  • Page 15 – IMPORTANT
  • Page 16 – PARTS UNDER WARRANTY; When Gas Pressure Is Too Low; SERVICE HINTS
  • Page 17 – PARTS CENTRALS
  • Page 19 – PARTS LIST; KEY
  • Page 20 – KEEP THIS WARRANTY; WARRANTY INFORMATION; LIMITED WARRANTY; INTERNATIONAL; NOT A UPC
Loading the manual

OWNER’S OPERATION AND INSTALLATION MANUAL

INFRARED VENT-FREE NATURAL GAS HEATER

CGN10RLA

Save this manual for future reference.

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity of
this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the gas
supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to

Air For Combustion

and Ventilation section on page
4 of this manual.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational
procedures. For assistance or
additional information consult
a qualified installer, service
agency, or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - NATURAL GAS HEATER; WARNINGS; WARNING: Any change to; Carbon Monoxide Poisoning:; Early signs of

2 104276 NATURAL GAS HEATER CGN10RLA SAFETYINFORMATION WARNINGS 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• shut off gas supply• do not try to light any appliance• do not touch any...

Page 3 - OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.; SAFETY PILOT

3 104276 OWNER’S MANUAL HeaterCabinet GrillGuard Burners FrontPanel Figure 1 - Vent-Free Natural Gas Heater Control Knob Piezo Ignitor Button PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of the Nationa...

Page 4 - Unusually Tight Construction

4 104276 NATURAL GAS HEATER CGN10RLA AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the cold ...