Desa CGD3018NT - Manual

Desa CGD3018NT

Desa CGD3018NT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – SAFETY INFORMATION; WARNINGS; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; DANGER: Carbon monoxide poisoning may lead; TABLE OF CONTENTS
  • Page 3 – Continued; PRODUCT IDENTIFICATION
  • Page 4 – LOCAL CODES; Where listed vented decorative logs are required, thermo-; AIR FOR COMBUSTION AND VENTILATION; PRODUCT FEATURES; OPERATION; Unusually Tight Construction; UNPACKING
  • Page 5 – Ventilation Air; Confined and Unconfined Space; per kw) of the aggregate input rating; WARNING: If the area in which the heater may be
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 4 - Ventilation Air from Outdoors
  • Page 7 – INSTALLATION; CHECK GAS TYPE; Vent-free heaters add moisture to the air. Although
  • Page 8 – Minimum Noncombustible Material Clearances; If Not Using Mantel; Noncombustible; Noncombustible material okay.; Installing Damper; Figure 5 - Minimum Clearance for Combustible to Wall; If Using Mantel
  • Page 9 – Determining Minimum Mantel Clearance; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain the; Figure 7 - Minimum Mantel Clearances Without Using Hood; Figure 8 - Minimum Mantel Clearances When Using Hood
  • Page 10 – INSTALLING HEATER BASE ASSEMBLY; Installation Items Needed; Figure 11 - Attaching Damper Clamp
  • Page 11 – Figure 12 - Attaching Flexible Gas Hose to Heater Gas Regulator; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-
  • Page 12 – CAUTION: Avoid damage to regulator. Hold gas; Figure 15 - Gas Connection; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS; Pressure Testing Gas Supply Piping system; Correct all leaks at once.; Figure 16 - Equipment Shutoff Valve; Install equipment shutoff valve in an accessible
  • Page 13 – Pressure Testing Heater Gas Connections; Open main gas valve located on or near gas meter.; Figure 17 - Checking Gas Joints; WARNING: Failure to position the parts in accor-; INSTALLING LOGS; CAUTION: After installation and periodically there-; Dual Burner Smoky Mountain Oak Models
  • Page 14 – Dual Burner Premium Aged Split Oak Models; Dual Burner Biltmore Split Oak Models
  • Page 15 – Locate pin and hole
  • Page 16 – Single Burner Seasonal Oak Models; Figure 35 - Installing Back Log
  • Page 17 – OPERATING HEATER (MANUALLY CONTROLLED MODELS); WARNING: If you do not follow these instructions; LIGHTING INSTRUCTIONS; • If fireplace has glass doors, never operate this; OPERATING HEATER; Manually-Controlled Models; WARNING: Damper handle will be hot if heater; Figure 38 - Control Knob and Ignitor Button Location
  • Page 18 – WARNING: Do not operate heater between PILOT; Shutting Off Heater; CAUTION: Do not try to adjust heating levels by
  • Page 19 – Figure 40 - Control Knob and Ignitor Button Location; Shutting Off Burners Only (pilot stays lit); TO TURN OFF GAS TO APPLIANCE
  • Page 20 – Follow steps 1 through 5 under Lighting Instructions, page 19.; Depress control knob and light pilot with match.; Selecting the HI setting with the control knob will cause; INSPECTING BURNERS; CLEANING AND MAINTENANCE; WARNING: Turn off heater and let cool before
  • Page 21 – LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages; MAIN BURNER; Blow air into the primary air holes on the injector holder.; SPECIFICATIONS; TBA
  • Page 22 – POSSIBLE CAUSE; All troubleshooting items are listed in; TROUBLESHOOTING
  • Page 23 – OBSERVED PROBLEM; nance, page 20) or replace burner orifice
  • Page 24 – IMPORTANT
  • Page 25 – OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB; For Masonry and Factory-built Metal Fireplace; Do not remove the screw. Make sure you tighten the; Figure 47 - Adhesive-backed Mounting Clip
  • Page 26 – ILLUSTRATED PARTS BREAKDOWN
  • Page 27 – PARTS LIST; Variable Manually-Controlled; PART NUMBER
  • Page 31 – KEY
  • Page 36 – SERVICE HINTS; When Gas Pressure Is Too Low; REPLACEMENT PARTS; PARTS UNDER WARRANTY; TECHNICAL SERVICE; EQUIPMENT SHUTOFF VALVE - GA5010; FIREPLACE HOOD
  • Page 37 – OWNER'S REGISTRATION FORM
  • Page 38 – Postage; TAPE
  • Page 39 – Baltimore Electric; PARTS CENTRAL
  • Page 40 – LIMITED WARRANTY; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
Loading the manual

UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATERS

OWNER’S OPERATION AND
INSTALLATION MANUAL

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

BILTMORE SPLIT OAK, SEASONAL OAK, AND

SMOKY MOUNTAIN OAK LOGS

Variable Manually-Controlled Models Also Designed Certified

As Vented Decorative Appliance

18", 24", and 30" Variable

Manually-Controlled Models

CGD3018N

CGD3924N

CGD3930N

CRL2718N

CCL3924N

CRL3124N

CCL3018N

18", 24" and 30"

Thermostatically-Controlled

Models

CGD3924NT

CGD3930NT

CGD3018NT

CCL3018NT

CCL3924NT

CCL3930NTA

Patent Pending

(Smoky Mountain Oak Model Shown)

WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

— Installation and service must be per-

formed by a qualified installer, service
agency, or the gas supplier.

WARNING: Improper installation, adjustment,
alteration, service, or maintenance can cause
injury or property damage. Refer to this
manual for correct installation and opera-
tional procedures. For assistance or addi-
tional information consult a qualified installer,
service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it
is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.

WARNING: This appliance is for installation
only in a solid-fuel burning masonry or UL127
factory-built fireplace, or in an approved
ventless firebox. It is design-certified for
these installations in accordance with ANSI
Z21.11.2.
Exception: Do not install this appliance in a
factory-built fireplace that includes instruc-
tions stating it has not been tested or should
not be used with unvented gas logs.

This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY INFORMATION; WARNINGS; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; DANGER: Carbon monoxide poisoning may lead; TABLE OF CONTENTS

107123-01E F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully andcompletely bef...

Page 3 - Continued; PRODUCT IDENTIFICATION

107123-01E F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION PRODUCT IDENTIFICATION UNPACKING 1. This appliance is only for use with the type of gas indicated onthe ra...

Page 4 - LOCAL CODES; Where listed vented decorative logs are required, thermo-; AIR FOR COMBUSTION AND VENTILATION; PRODUCT FEATURES; OPERATION; Unusually Tight Construction; UNPACKING

107123-01E F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, use the latest edition of T...

Other Desa Models