- Page 2 – UNVENTED PROPANE/LP GAS LOG HEATER; Carbon Monoxide Poisoning:; WARNINGS; WARNING: Any change to
- Page 3 – OWNER’S MANUAL; Operation; Do not pick up; UNPACKING; American National Standards Institute, Inc.
- Page 4 – Unusually Tight Contruction; Unusually Tight Construction; per
- Page 5 – Determining if You Have a Confined or Unconfined Space; Continued
- Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building
- Page 7 – INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace; LOG SIZING REQUIREMENTS; Left and
- Page 8 – If Not Using Mantel; If using a mantel, proceed to If Using; If Using Mantel; If you cannot meet these; Requirements for
- Page 9 – Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; Floor Clearances; A. If installing appliance on the floor level,; flue damper open; Figure 7 - Minimum Mantel Clearances When Using Hood; Hearth
- Page 10 – External Regulator; CAUTION: Never connect; Installation Items Needed; WARNING: If installing in a; Fitting; CAUTION: Do not remove the
- Page 11 – CAUTION: Avoid damage to; Correct all leaks at once.; Figure 13 - Gas Connection; Tee Joint
- Page 12 – Figure 14 - Manual Shutoff Valve; Open; Figure 15 - Checking Gas Joints; Open propane supply tank valve.; Propane Tank; Battery Cover
- Page 13 – WARNING: Failure to position; CAUTION: After installation
- Page 15 – Figure 27 - Control Knob and Ignitor Button Location; • If fireplace has glass doors,; FOR YOUR SAFETY; WARNING: Damper handle; Control Knob
- Page 16 – CAUTION: Do not try to adjust; Pilot Burner; Lighting; Remote Selector Switch in Remote Position; Shutting Off Heater; Do not leave the re-; IMPORTANT
- Page 17 – WARNING: Turn off heater; • Use a vacuum cleaner or small, soft; LOGS; • If you remove logs for cleaning, refer to; Figure 29 - Thermostat Hand-Held Remote Control Unit Selections; Shows Temperature Setting; Figure 30 - Correct Pilot Flame Pattern; Figure 31 - Incorrect Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; MAIN BURNER
- Page 18 – TROUBLESHOOTING; All troubleshooting items are listed in; POSSIBLE CAUSE
- Page 19 – OBSERVED PROBLEM; nance, page 17) or replace burner orifice
- Page 21 – SPECIFICATIONS; When Gas Pressure Is Too Low; WIRING DIAGRAM
- Page 23 – PARTS LIST; PART NUMBER
- Page 25 – KEY
- Page 26 – PARTS UNDER WARRANTY; PARTS CENTRAL
- Page 27 – NOTES
- Page 28 – For information about this warranty write:; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
Save this manual for future reference.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
n e i g h b o r ’ s p h o n e . F o l l o w t h e g a s
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This appliance is for instal-
lation only in a solid-fuel burning ma-
sonry or UL127 factory-built fireplace,
or in an approved ventless firebox. It is
design certified for these installations
in accordance with ANSI Z21.11.2.
Exception: Do not install this appliance
in a factory-built fireplace that includes
instructions stating it has not been
tested or should not be used with
unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
®
PREMIUM AGED SPLIT OAK
AND YELLOW FLAME UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
PIL
O T
O
F
F
O
N
LO
REMOTE
OFF
HI
CGD3924PR
CGB3924PR
CGB3930PR
24" and 30" Remote
Controlled Models
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
(Yellow Flame Model Shown)
Remote Control
Operation Requires
Two (2) 9-Volt Alkaline
Batteries Not Included
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 104307 UNVENTED PROPANE/LP GAS LOG HEATER CGD3924PR, CGB3924PR and CGB3930PR SAFETYINFORMATION IMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-ate, or service this heater. Im-proper use of this heater can causeserious injury or death from burns,fire, expl...
3 104307 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - Vent-Free Gas Log Heater (Logs May Vary By Model) Operation This heater is clean burning. It requires nooutside venting. There is no heat loss out avent or up a chimney. Heat is generated byrealistic dancing, yellow flames. This heateris desig...
4 104307 UNVENTED PROPANE/LP GAS LOG HEATER CGD3924PR, CGB3924PR and CGB3930PR AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk...