Desa CCL3930PTB - Manual

Desa CCL3930PTB

Desa CCL3930PTB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
Page: / 42

Table of Contents:

  • Page 2 – SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS
  • Page 3 – Continued; PRODUCT IDENTIFICATION
  • Page 4 – Unusually Tight Construction; LOCAL CODES; OPERATION; PRODUCT FEATURES
  • Page 5 – Confined and Unconfined Space; per kw) of the aggregate input rating of all; WARNING: If the area in which the heater may be; AIR FOR COMBUSTION AND VENTILATION; Ventilation Air
  • Page 6 – Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 4 - Ventilation Air from Outdoors
  • Page 7 – Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; INSTALLATION
  • Page 8 – Figure 5 - Minimum Clearance for Combustible to Wall; Minimum Noncombustible Material Clearances; Noncombustible material okay.; *Minimum 16 inches from Side Wall
  • Page 9 – Figure 7 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; Determining Minimum Mantel Clearance; A. If installing appliance on the floor level, you must maintain; Figure 8 - Minimum Mantel Clearances When Using Hood
  • Page 10 – Installation Items Needed
  • Page 11 – WARNING: A qualified service person must con-; Figure 12 - Attaching Flexible Gas Hose to Heater Gas Regulator; Remove heater base from fireplace.; Fitting; CONNECTING TO GAS SUPPLY
  • Page 12 – CAUTION: Avoid damage to regulator. Hold gas; Figure 16 - Gas Connection; Pressure Testing Gas Supply Piping system; Correct all leaks at once.; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS; Install equipment valve in an accessible location.; WARNING: Use pipe joint sealant that is resistant; Cap
  • Page 13 – Figure 17 - Equipment Shutoff Valve; Open; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; WARNING: Failure to position the parts in accor-; INSTALLING LOGS; CAUTION: After installation and periodically there-; Gas Meter
  • Page 15 – Tab; Locate
  • Page 16 – Figure 32 - Installing Back Log; Locate holes on the bottom of
  • Page 17 – Front Log; Figure 34 - Installing Crossover Log; Post; OPERATING HEATER; FOR YOUR SAFETY; WARNING: If you do not follow these instructions; LIGHTING
  • Page 18 – Shutting Off Heater; CAUTION: Do not try to adjust heating levels by; VARIABLE CONTROL; WARNING: Do not operate heater between PILOT; Figure 35 - Control Knob and Ignitor Button Location; Ignitor Button; WARNING: Damper handle will be hot if heater; Control Knob; OPERATING HEATER (Manually Controlled Models)
  • Page 19 – WARNING; THERMOSTAT-CONTROLLED MODELS
  • Page 20 – Selecting the HI setting with the control knob will cause the; Figure 37 - Control Knob and Ignitor Button Location; Shutting Off Burners Only (pilot stays lit); INSPECTING BURNERS
  • Page 21 – CLEANING AND MAINTENANCE; WARNING: Turn off heater and let cool before; Blow air through the ports/slots and holes in the burner.; Figure 41 - Injector Holder On Outlet Burner Tube; LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages; MAIN BURNER; Figure 42 - Pilot Inlet Air Hole; Burner Tube
  • Page 22 – POSSIBLE CAUSE; All troubleshooting items are listed in; TROUBLESHOOTING
  • Page 23 – OBSERVED PROBLEM
  • Page 24 – IMPORTANT; Operating heater where impurities in air exist may create odors.
  • Page 25 – Do not remove the screw. Make sure you tighten the; Figure 44 - Adhesive-backed Mounting Clip; OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB; Capillary
  • Page 26 – SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; You can also visit DESA’s technical service web site at; PARTS UNDER WARRANTY; When calling DESA, have ready; PARTS NOT UNDER WARRANTY; REPLACEMENT PARTS; EQUIPMENT SHUTOFF VALVE - GA5010
  • Page 27 – DUAL BURNER SMOKY MOUNTAIN OAK MODELS; SPECIFICATIONS
  • Page 28 – ILLUSTRATED PARTS BREAKDOWN
  • Page 29 – PARTS LIST
  • Page 37 – KEY; PARTS AVAILABLE — NOT SHOWN
  • Page 38 – Baltimore Electric; PARTS CENTRAL
  • Page 39 – OWNER'S REGISTRATION FORM
  • Page 40 – Postage; T APE
  • Page 41 – NOTES
  • Page 42 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:; NOT A UPC
Loading the manual

WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.

— D o n o t s t o r e o r u s e g a s o l i n e o r o t h e r

flammable vapors and liquids in the vicinity of
this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the gas

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design-
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it
is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.

18", 24", and 30" Variable

Manually-Controlled Models

CRL2718P/N
CRL3124P/N

CCL3018PA/NA
CCL3924PA/NA

18", 24", and 30"

Thermostatically-Controlled Models

CGD3924PT/NT
CGD3018PT/NT

CCL3018PTA/NTA
CCL3924PTA/NTA
CCL3930PTB/NTB

Patent Pending

This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

(Smoky Mountain Oak Model Shown)

UNVENTED (VENT-FREE)
GAS LOG HEATER

OWNER’S OPERATION AND
INSTALLATION MANUAL

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

BILTMORE SPLIT OAK, SEASONAL OAK

AND SMOKY MOUNTAIN OAK LOGS

Variable Manually-Controlled Models Also

Design-Certified As Vented Decorative Appliances

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS

111160-01B F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 SAFETY INFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxi...

Page 3 - Continued; PRODUCT IDENTIFICATION

111160-01B F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 SAFETY INFORMATION Continued 1. This appliance is only for use with the type of gas indicated onthe rating plate. This applia...

Page 4 - Unusually Tight Construction; LOCAL CODES; OPERATION; PRODUCT FEATURES

111160-01B F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 AIR FOR COMBUSTION ANDVENTILATION Today’s homes are built more energy efficient than ever. Newmaterials, increased insulation, ...

Other Desa Models