Table of Contents:
- Page 2 – SAFETY INFORMATION; WARNINGS; WARNING: This product contains and/or generates; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNING: Any change to this heater or its controls; TABLE OF CONTENTS
- Page 3 – Continued; PRODUCT IDENTIFICATION
- Page 4 – LOCAL CODES; CAUTION: Do not remove the data plates attached; PRODUCT FEATURES; OPERATION; WARNING: This heater shall not be installed in a
- Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
- Page 6 – WARNING: If the area in which the heater may be; VENTILATION AIR; Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors
- Page 7 – INSTALLATION; Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; ALL
- Page 8 – Minimum Noncombustible Material Clearances; If Not Using Mantel; Installing Damper; Noncombustible material okay.
- Page 9 – Determining Minimum Mantel Clearances; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood; Figure 7 - Minimum Mantel Clearances When Using Hood
- Page 10 – When used as a vented heater, appliance must be installed; Figure 10 - Attaching Damper Clamp; Manufactured Fireplace; INSTALLING HEATER BASE ASSEMBLY; Make sure the heater burners are level. If heater is
- Page 11 – Figure 11 - Attaching Flexible Gas Hose to Heater; Figure 12 - Attaching Base Assembly to Fireplace Floor; Installation Items Needed; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-
- Page 12 – Install equipment shutoff valve in an accessible; Figure 14 - Gas Connection; Figure 13 - External Regulator With Vent Pointing Down; CHECKING GAS CONNECTIONS; Pressure Testing gas Supply Piping system
- Page 13 – Pressure Testing Heater Gas Connections; Figure 15 - Equipment Shutoff Valve; Figure 16 - Checking Gas Joints; INSTALLING REMOTE RECEIVER UNIT; Figure 19 - Installing Remote Receiver
- Page 14 – Installing 9-Volt Battery in Receiver; Figure 21 - Installing Receiver on the Back of the Base; WARNING: Failure to position the parts in accor-
- Page 15 – Locate holes on the bottom of cross-
- Page 16 – WARNING: If you do not follow these instructions; OPERATING HEATER; FOR YOUR SAFETY READ; WARNING: Damper handle will be hot if heater; Figure 32 - Control Knob and Ignitor Button Location; WARNING: Burners will come on automatically
- Page 17 – CAUTION: Do not try to adjust heating levels by; Shutting Off Heater; Do not leave the selector switch in the RE-; CGHRC Series Operation:; Natural Gas
- Page 18 – CGHRCTA Series Operation:; manual mode when ON is lit.; The hand-held remote control unit must; To turn the pilot off, manually turn the con-; INSPECTING BURNERS; Check pilot flame pattern and burner flame patterns often.; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to Appliance, page 17); Figure 36 - Correct Pilot Flame Pattern; MAIN BURNER; WIRING DIAGRAM
- Page 19 – WARNING: Turn off heater and let cool before; Blow air through the ports/slots and holes in the burner.; Figure 38 - Injector Holder On Outlet Burner Tube; LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages; CLEANING AND MAINTENANCE
- Page 20 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 21 – OBSERVED PROBLEM; nance, page 19) or replace burner orifice
- Page 22 – IMPORTANT
- Page 23 – TECHNICAL SERVICE; When Gas Pressure Is Too Low; REPLACEMENT PARTS; PARTS UNDER WARRANTY; SPECIFICATIONS
- Page 24 – ILLUSTRATED PARTS BREAKDOWN
- Page 25 – PARTS LIST; KEY
- Page 28 – ACCESSORIES; FIREPLACE HOOD; PARTS CENTRAL
- Page 29 – OWNER'S REGISTRATION FORM
- Page 30 – Postage; T APE
- Page 31 – NOTES
- Page 32 – LIMITED WARRANTY; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC
UNVENTED (VENT-FREE)
GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• D o n o t t o u c h a n y e l e c t r i c a l
switch; do not use any phone in
your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, ser-
vice agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
PIL
O T
O
F
F
O
N
LO
REMOTE
OFF
HI
(Yellow Flame Model Shown)
CCL3018NR, CCL3018NRA
CCL3018PR, CCL3018PRA
CCL3924NR, CCL3924NRA
CCL3924PR, CCL3924PRA
CCL3930NR, CCL3930NRA
CCL3930PR, CCL3930PRA
18", 24" and 30" Remote Ready
Also Design-Certified As Vented Decorative Appliances When
Not Used With Hand-Held Thermostat Remote
WARNING: Improper installation, adjustment, al-
teration, service, or maintenance can cause injury
or property damage. Refer to this manual for cor-
rect installation and operational procedures. For
assistance or additional information consult a quali-
fied installer, service agency, or the gas supplier.
WARNING: This appliance is for installation only
in a solid-fuel burning masonry or UL127 factory-
built fireplace, or in an approved ventless firebox.
It is design-certified for these installations in ac-
cordance with ANSI Z21.11.2.
Exception: Do not install this appliance in a fac-
tory-built fireplace that includes instructions stat-
ing it has not been tested or should not be used
with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and
ventilation air must be provided. Refer to
Air for
Combustion and Ventilation section on page 4.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
111161-01A 2 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION WARNINGS WARNING: This product contains and/or generates chemicals known...
111161-01A 3 3 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION PRODUCT IDENTIFICATION 1. This appliance is only for use with the type of gas indicated onthe rating plate...
111161-01A 4 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, use the latest edition of T...