  • Page 2 – INSTALLATION; Eave Mount
  • Page 3 – TEST AND ADJUSTMENT; RANGE; Bottom of Sensor; SPECIFICATIONS; Motion
  • Page 4 – TROUBLESHOOTING GUIDE; TECHNICAL SERVICE; No Service Parts Available for this Product
  • Page 5 – Requisitos; FUNCIONAMIENTO; Mueva el interruptor de; Resumen de las modalidades del interruptor; PRUEBA
  • Page 6 – INSTALACION; Montaje en alero
  • Page 7 – PRUEBA Y AJUSTE
  • Page 8 – GUIA DE INVESTIGACION DE AVERIAS; SERVICIO TÉCNICO; de devolver el producto a la tienda.
Loading the manual

© 2007 DESA Specialty Products™

598-1311-00

1 Halogen

Lamp

Sensor

Light Control

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

• Some codes require installation by a qualifi ed

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

Motion Sensing
Halogen Fixture

Model 5525

3 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

Mounting Bolt

Mounting Strap

OPERATION

* resets to Auto Mode at dawn.

MANUAL MODE

ON-TIME

10 5 1

TEST

10 5 1

TEST

ON-TIME

TEST

AUTO

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switch Summary

Flip light switch

off for one second

then back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Note: When fi rst turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Light Shield

Plastic Hanger

Rubber Plug

Put the ON-TIME switch on the bottom
of the sensor in the TEST position.

Put the ON-TIME switch in the 1, 5,
or 10 minute position.

Manual mode only works at night
because daylight returns the sen-
sor to AUTO.

Flip the light switch off for one sec-
ond then back on to toggle between
AUTO and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

This package includes:

Mode:

On-Time

Works:

Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

x

Manual

Until Dawn*

x

... back on.

1 Second OFF

then

...

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; Eave Mount

2 598-1311-00 INSTALLATION For easy installation, select an existing light with a wall switch for replacement. For best performance, mount the fi xture about 8 ft. (2.4 m) above the ground. W IRE THE L IGHT C ONTROL B ULB I NSTALLATION ❒ When relamping, turn power off and let the fi xture cool. ❒ Re...

Page 3 - TEST AND ADJUSTMENT; RANGE; Bottom of Sensor; SPECIFICATIONS; Motion

3 598-1311-00 TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffi c may trigger the contro...

Page 4 - TROUBLESHOOTING GUIDE; TECHNICAL SERVICE; No Service Parts Available for this Product

4 598-1311-00 POSSIBLE CAUSE 1. The lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects.) 2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted...