Desa 4E769B - Manual
Desa 4E769B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Dayton Operating Instructions and Parts Manual; General Safety Information; IMPORTANT
- Page 3 – Specifications; ELECTRICAL SPECIFICATIONS; Manual; GENERAL SPECIFICATIONS
- Page 4 – Product Identification
- Page 5 – Propane Supply; Standard for Storage; Figure 3 - Cross Section Operational View; Theory of Operation; THE FUEL SYSTEM; The piezo ignitor lights the burner.; THE AUTOMATIC CONTROL SYSTEM
- Page 6 – Installation; Figure 4 - Regulator Position; Figure 5 - Hose and Inlet Connector; Operation; TO START HEATER; Ventilation
- Page 7 – Storage; Standard; Maintenance; NOTE; To Start Heater
- Page 8 – SERVICE PROCEDURES
- Page 10 – Figure 17 - Replacement Parts Illustration
- Page 11 – Replacement Parts List; Description
- Page 12 – Troubleshooting Chart; Symptom
- Page 13 – Accessories
- Page 14 – Notes
- Page 16 – LIMITED WARRANTY; LIMITATION OF LIABILITY.
Operating Instructions & Parts Manual
Dayton Propane
Construction Heater
Description
Dayton Model 4E769B heater is a 35,000 BTU/Hr construction heater. This heater
uses propane gas for combustion and electricity to run the motor. It is primarily
intended for temporary heating of buildings under construction, alteration, or
repair. This heater should only be used indoors but never in occupied dwellings.
®
Form 5S3439
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
4E769B
Version B - For Reduction
G016.J
Fire, burn,
inhala-
tion, and explosion haz-
ard. Keep solid combus-
tibles such as building
materials, paper or card-
board, a safe distance
away from the heater as
recommended by the
instructions. Never use
the heater in spaces
which do or may contain
volatile or airborne com-
bustibles, or products
such as gasoline, sol-
vents, paint thinner, dust
particles, or unknown
chemicals.
Heater is designed and approved for use
as a construction heater under ANSI
Z83.7. The primary purpose of construc-
tion heaters is to provide temporary
heating of buildings under construction,
alteration or repair, and to provide
temporary emergency heat. Properly
used, the heater provides safe economi-
cal heating. Products of combustion are
vented into the area being heated.
We cannot foresee every use which may
be made of our heaters.
Check with your
local fire safety authority if you have
questions about heater use.
Other standards govern the use of fuel
gases and heat producing products for
specific uses. Local authorities can advise
you about these.
Not for
home or
recreational vehicle use.
Unpacking
1. Remove all packing items applied to
heater for shipment. Keep plastic
cover caps (attached to inlet connec-
tor and hose/regulator assembly) for
storage.
2. Remove all items from carton.
3. Check all items for shipping damage.
If heater is damaged, promptly
inform dealer where you bought
heater.
GENERAL HAZARD
WARNING
Failure to comply with
the precautions and in-
structions provided with
this heater can result in
death, serious bodily
injury, and property loss
or damage from hazards
of fire, explosion, burn,
asphyxiation, carbon
monoxide poisoning, and/
or electrical shock.
Only persons who can
understand and follow
instructions should use or
service this heater.
If you need assistance or
heater information such
as an instructions
manual, labels, etc. con-
tact the manufacturer.
Figure 1 – Model 4E769B
Printed in U.S.A.
03430
1199/511/VCPVP
®
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Dayton Operating Instructions and Parts Manual 2 Dayton PropaneConstruction Heater ® 4E769B General Safety Information Carbon monoxidepoisoning may lead to death! Some people are moreaffected by carbon monoxide thanothers. Early signs of carbon monoxidepoisoning resemble the flu, withheadaches, dizz...
Dayton Operating Instructions and Parts Manual 3 Model 4E769B Version B - For Reduction G016.J ® Specifications ELECTRICAL SPECIFICATIONS ElectricalInput Amperage 120 Volt/60Hertz 2 General Safety Information (Continued) Manifold Hot Air Output Supply Pressure Temperature Range Pressure (CFM Approx)...
Dayton Operating Instructions and Parts Manual 4 Dayton PropaneConstruction Heater ® 4E769B Product Identification Figure 2 – Model 4E769B Shell Handle Motor PowerCord Hot Air Outlet (Front) Fan Guard Heater Base Piezo IgnitorButton AutomaticControl ValveButton InletConnector Hose /RegulatorAssembly