Page 3 - Table of Contents
Dell iii PowerEdge R210 II Technical Guide Table of Contents 1 Product Comparison ........................................................................................... 7 1.1 Overview .................................................................................................. 7 1.2 Key Be...
Page 5 - Tables
Dell v PowerEdge R210 II Technical Guide 14.2 Rails ...................................................................................................... 41 14.3 Cable Management Arm (CMA) ....................................................................... 42 14.4 Rack View .......................
Page 6 - Figures
Dell vi PowerEdge R210 II Technical Guide Figures Figure 1. Chassis Dimensions .................................................................................. 13 Figure 2. Front View (With Bezel) ............................................................................ 14 Figure 3. Front View ...
Page 7 - Product Comparison; Overview; The PowerEdge R210 II; Key Benefits; Business Value; : Manage the R210 II with the full suite of Dell OpenManage systems; Better Performance with Less Noise; : Business performance with similar sound levels as a; Flexible, Secure Technology; Windows
Dell 7 PowerEdge R210 II Technical Guide 1 Product Comparison 1.1 Overview The PowerEdge R210 II is an entry-level, yet enterprise ready, ultra-dense 1-socket 1U rack server that is well suited for a broad range of workloads, from small businesses applications to high-density, scale-out compute farm...
Page 8 - Easy to Manage; The Dell PowerEdge R210 II lets you focus on running your business; Comparison
Dell 8 PowerEdge R210 II Technical Guide 1.4 Easy to Manage The Dell PowerEdge R210 II lets you focus on running your business rather than running your servers. Dell OpenManage systems management software helps to automate common management tasks, thereby enhancing efficiency, improving productivity...
Page 10 - New Technologies
Dell 10 PowerEdge R210 II Technical Guide 2 New Technologies New technologies on the Dell PowerEdge™ R210 II include the following: New processors, including the Intel ® Xeon ® processor E3-1200 product family and the Intel Core™ processor i3-2100 product family Improved acoustics in small offic...
Page 11 - System Overview; Product Feature Summary
Dell 11 PowerEdge R210 II Technical Guide 3 System Overview Table 2. Product Feature Summary Feature Technical Specification Form Factor 1U rack Processors Quad-core Intel ® Xeon ® processor E3-1200 product family Dual-core Intel Core™ processor i3-2100 product family Processor Sockets 1 Front Side ...
Page 13 - Mechanical; Chassis Description; Chassis Dimensions
Dell 13 PowerEdge R210 II Technical Guide 4 Mechanical 4.1 Chassis Description The PowerEdge R210 II is a 1U rack-mount design that supports the following features: Two cabled 3.5‖ drive bays for SATA or SAS hard drives or four 2.5‖ drive bays for SAS or SSD drives (available Q2 2011) Dual Gigab...
Page 14 - Front Panel View and Features; Back Panel View and Features; Back View; PowerEdge R210 II Owner’s Manual; Power Button LED
Dell 14 PowerEdge R210 II Technical Guide 4.3 Front Panel View and Features Figure 2 and Figure 3 show the front views of the PowerEdge R210 II. Figure 2. Front View (With Bezel) Figure 3. Front View (Without Bezel) See the Front-Panel Features and Indicators section in the About Your System chapter...
Page 15 - Power Button; System Status ID; NIC Indicators; Owner’s Manual; Internal Chassis Views
Dell 15 PowerEdge R210 II Technical Guide Figure 5. Power Button See the About Your System chapter of the PowerEdge R210 II Owner’s Manual on Support.Dell.com for more information. 4.6 System Status ID The System Status ID indicators are two LEDs—one on the front panel of the system and one on the b...
Page 16 - Internal Chassis View; Rails; ReadyRails Static Rails; Fans
Dell 16 PowerEdge R210 II Technical Guide Figure 6. Internal Chassis View 4.9 Rails 4.9.1 ReadyRails Static Rails ReadyRails TM Static Rails for 4-post and 2-post racks support the following: Toolless installation in 19‖ EIA-310-E compliant square or unthreaded round hole 4-post racks including al...
Page 17 - LED Control Panel; Front Panel View with LED Control Panel; Security; Cover Latch
Dell 17 PowerEdge R210 II Technical Guide For information on removing and installing the system fans, see the Installing System Components chapter of the PowerEdge R210 II Owner’s Manual on Support.Dell.com for more information. 4.11 LED Control Panel Figure 7 and Figure 8 show the LED control panel...
Page 18 - USB Key
Dell 18 PowerEdge R210 II Technical Guide The TPM is used to generate and store keys, protect and authenticate passwords, and create and store digital certificates. The TPM can also be used to store Microsoft ® BitLocker™ keys for hard drive encryption features in Microsoft ® Windows Server ® 2008. ...
Page 19 - Power Supplies; Power Supply Specifications; Heat Dissipation
Dell 19 PowerEdge R210 II Technical Guide 5 Power, Thermal, Acoustic 5.1 Power Supplies The base system includes a single 250W power supply. This unit provides power to the planar, the internal hard drive bays, and one slim optical disk drive bay. Power is soft-switched, allowing power cycling using...
Page 20 - Environmental Specifications; Formulas for Maximum Operating Temperature for Given Altitude (°C)
Dell 20 PowerEdge R210 II Technical Guide 5.4 Environmental Specifications The airborne contaminant level is class G2 or lower as defined by ISA-S71.04-1985. Table 4 lists the environmental specifications for the R210 II. Table 4. Environmental Specifications Specification Operating Requirements Non...
Page 21 - Shock and Vibration Specifications; ENERGY STAR Compliance; ENERGY STAR Compliance results; Thermal; Comprehensive thermal management; Acoustics; Adherence to Dell’s high sound quality standards:
Dell 21 PowerEdge R210 II Technical Guide Table 5 shows the shock and vibration specifications for the R210 II. Table 5. Shock and Vibration Specifications Maximum Vibration Operating 0.26Grms at 5–350Hz for 15 minutes Storage 1.88Grms at 10–500Hz for 15 minutes Maximum Shock Operating One shock pul...
Page 22 - Hardware configurations affect system noise levels:; Dell‘s thermal control provides for; Noise ramp and descent at boot:; Fan speeds (and corresponding noise levels) ramp up during; Acoustical Specifications; Definitions
Dell 22 PowerEdge R210 II Technical Guide Hardware configurations affect system noise levels: Dell‘s thermal control provides for cooling flexible to varying hardware configurations. Acoustical performance associated with two common configurations is listed in Table 6. Noise ramp and descent at ...
Page 24 - Processors; Supported Intel Xeon Processors
Dell 24 PowerEdge R210 II Technical Guide 6 Processors 6.1 Overview The processors for the R210 II are based on the latest two- and four-core offerings from the Intel ® Xeon ® processor E3-1200 product family or the Intel ® Core™ processor i3-2100 product family series. 6.2 Features Key features of ...
Page 25 - Supported Intel Desktop Processors; Processor Configurations; Dell PowerEdge
Dell 25 PowerEdge R210 II Technical Guide Table 8. Supported Intel Desktop Processors Model Speed (GHz) Power (Watts) Cores L2/L3 Cache (MB) Threads Turbo Memory (MHz) Process Intel Core™ i3-2100 3.10 65 2 3 4 No 1333 32nm Intel Pentium ® G850 2.90 65 2 3 2 No 1333 32nm Intel Pentium G620 2.60 65 2 ...
Page 26 - Memory; DIMMs Supported; DIMM Slots
Dell 26 PowerEdge R210 II Technical Guide 7 Memory 7.1 Overview The R210 II supports DDR3 memory, providing a high performance, high speed memory interface capable of low latency response and high throughput. For the Intel processor-based R210 II, up to 4 total DIMMs are supported. Additional specif...
Page 27 - Supported Configurations
Dell 27 PowerEdge R210 II Technical Guide For dual-rank memory modules o One memory module per channel supports up to 1333 MHz o Two memory modules per channel supports up to 1066 MHz If memory modules with different speeds are installed, they will operate at the speed of the slowest installed mem...
Page 28 - Chipset
Dell 28 PowerEdge R210 II Technical Guide 8 Chipset 8.1 Overview The PowerEdge R210 II planar incorporates the Intel C200 Series PCH chipset. The features listed below are part of the chipset. 8.2 Direct Media Interface Direct Media Interface (DMI) is the chip-to-chip connection between the processo...
Page 29 - Compatibility Module
Dell 29 PowerEdge R210 II Technical Guide Intel ® Active Management Technology, and integrated Intel Quiet System Technology. The chipset supports up to two SPI flash devices with speed up to 20 MHz, 33 MHz utilizing two chip select pins. 8.9 Compatibility Module The DMA controller incorporates the ...
Page 30 - GPIO; TCO Timer
Dell 30 PowerEdge R210 II Technical Guide functions. The first ten are for time and date information. The next four (0Ah to 0Dh) are registers, which configure and report RTC functions. 8.13 GPIO Various general purpose inputs and outputs are provided for custom system design. The number of inputs a...
Page 31 - Intel Virtualization Technology for Directed I/O
Dell 31 PowerEdge R210 II Technical Guide 8.16 System Management Bus (SMBus 2.0) The chipset contains an SMBus Host interface that allows the processor to communicate with SMBus slaves. This interface is compatible with most I2C devices. Special I2C commands are implemented. The chipset‘s SMBus host...
Page 32 - BIOS
Dell 32 PowerEdge R210 II Technical Guide 9 BIOS 9.1 Overview The R210 II BIOS is based on the Insyde ® BIOS core which supports the following features: Simultaneous Multi-Threading (SMT) support PCI 2.3 compliant Plug and Play 1.0a compliant MP (Multiprocessor) 1.4 compliant Ability to bo...
Page 33 - Supported ACPI States; S4 supported by OS only; Supported ACP; Power Management Modes; The R210 II uses operating system-based power management.; Maximum Performance; Generic
Dell 33 PowerEdge R210 II Technical Guide 9.2 Supported ACPI States ● ACPI compliance: S0, S4, S5 supported ● No S1, S2, S3 (STR) support ● S4 supported by OS only Table 11. Supported ACP I States Events (Wake Up) S0 System ON S1 S2/S3 S4 Hibernate (OS supported) S5 Soft Off Power Button — — R...
Page 34 - Power Management Features
Dell 34 PowerEdge R210 II Technical Guide Table 12. Power Management Features Feature Type Enable/Status/ Ctrl bit location Description ACPI mode switch Fixed PCH The OS uses the SCI_EN bit to switch from legacy mode to ACPI mode. Sleep states Fixed PCH Supported states: S0(Working), S4-OS (‗Hiberna...
Page 35 - Power Profiles
Dell 35 PowerEdge R210 II Technical Guide Table 13 shows the power profile options for the R210 II. Table 13. Power Profiles Maximum Performance DBPM Disabled (BIOS sets P-State to max) Memory frequency = Maximum Performance Fan algorithm = Maximum Performance OS Control Enable OS DBPM Control (BIOS...
Page 37 - PCI Slots; Slot supports full-height half-length cards connected to the IOH; Quantities and Priorities; PCI Card Dimensions; Dell PowerEdge R210 II Owner’s Manual
Dell 37 PowerEdge R210 II Technical Guide 11 PCI Slots 11.1 Overview The PowerEdge R210 II planar provides one riser card which provides one x16 Gen2 PCI Express expansion slot: Slot supports full-height half-length cards connected to the IOH Support for 25W maximum power System does not suppo...
Page 38 - Storage; x 3.5‖ cabled SATA drives using the motherboard SATA connector; Hard Drives; Supported Hard Drives; RAID Configurations; Factory RAID Configurations
Dell 38 PowerEdge R210 II Technical Guide 12 Storage 12.1 Overview The PowerEdge R210 II supports the following hard drive configurations: 2 x 3.5‖ cabled SATA drives using the motherboard SATA connector 2 x 3.5‖ cabled SAS, nearline SAS, or SATA drives using an add-on storage controller 4 x 2...
Page 40 - Video; The PowerEdge R210 II includes a Matrox; Graphics Video Modes
Dell 40 PowerEdge R210 II Technical Guide 13 Video The PowerEdge R210 II includes a Matrox ® G200eW with 8 MB memory integrated in Winbond ® WPCM450 (BMC controller). The resolutions supported are listed in Table 16. Table 16. Graphics Video Modes Resolution Refresh Rate (Hz) Color Depth (bit) 640 x...
Page 41 - Rack Information; Supported Racks; Rail Adjustability Ranges and Depth
Dell 41 PowerEdge R210 II Technical Guide 14 Rack Information 14.1 Overview The ReadyRails™ static rail systems for the R210 II provide toolless support for racks with square or unthreaded round mounting holes including all generations of Dell racks. The rail systems also offer tooled mounting suppo...
Page 42 - Rack View; A4 Static Rail System
Dell 42 PowerEdge R210 II Technical Guide The min-max values listed in Table 18 represent the allowable distance between the front and rear mounting flanges in the rack. Rail depth represents the minimum depth of the rail as measured from the rack front mounting flanges when the rail rear bracket is...
Page 43 - A4 and A6 Rail Systems in 2-post Center-Mount Configuration
Dell 43 PowerEdge R210 II Technical Guide Figure 13 shows a view of the R210 II mounted in the A4 A6 rail systems in the 2-post center-mount configuration. The rear brackets on the A6 rail system can be removed and discarded, providing a much smaller mounting footprint than the A4 rail system. Figur...
Page 44 - Operating Systems; For detailed information, see the following:
Dell 44 PowerEdge R210 II Technical Guide 15 Operating Systems For detailed information, see the following: Operating System Support Matrix for Dell PowerEdge Systems on Dell.com Dell PowerEdge R210 II Getting Started Guide on Support.Dell.com
Page 45 - Systems Management; Deployment of one or many servers from a single console; Server Management
Dell 45 PowerEdge R210 II Technical Guide 16 Systems Management 16.1 Overview Dell delivers open, comprehensive, and integrated solutions that help you reduce the complexity of managing disparate IT assets. Combining Dell PowerEdge Servers with a wide selection of Dell developed systems management s...
Page 46 - Embedded Server Management; Dell Lifecycle Controller; Unified Server Configurator Features and Description
Dell 46 PowerEdge R210 II Technical Guide 16.3 Embedded Server Management The PowerEdge R210 II implements circuitry for the next generation of Embedded Server Management. It is Intelligent Platform Management Interface (IPMI) v2.0 compliant. The optional iDRAC (Integrated Dell Remote Access Control...
Page 50 - Peripherals; The PowerEdge R210 II supports the following USB devices:
Dell 50 PowerEdge R210 II Technical Guide 17 Peripherals The PowerEdge R210 II supports the following USB devices: DVD (bootable; requires two USB ports) USB key (bootable) Keyboard (only one USB keyboard is supported) Mouse (only one USB mouse is supported)
Page 51 - Statement of Volatility; Volatility Table
Dell 51 PowerEdge R210 II Technical Guide Appendix A. Statement of Volatility The Dell PowerEdge R210 II contains both volatile and non-volatile (NV) components. Volatile components lose their data immediately upon removal of power from the component. Non-volatile components continue to retain their...
Page 54 - Certifications; Regulatory Certifications; Product Safety Certifications
Dell 54 PowerEdge R210 II Technical Guide Appendix B. Certifications B 1. Regulatory Certifications Regulatory compliance certificates can be located at the following sites: http://ausreactorprd01/reactor/xCertSearch.asp http://www.dell.com/content/topics/global.aspx/about_dell/values/regulatory...
Page 55 - Electromagnetic Compatibility; Electromagnetic Compatibility Certifications; Ergonomics, Acoustics and Hygienics
Dell 55 PowerEdge R210 II Technical Guide B 3. Electromagnetic Compatibility The product has been certified and bears the Mark, as applicable, of the EMC authorities as indicated in Table 23. Table 23. Electromagnetic Compatibility Certifications Country/Region Authority or Mark Class Australia/New ...
Page 56 - Industry Standards
Dell 56 PowerEdge R210 II Technical Guide Appendix C. Industry Standards The PowerEdge R210 II system conforms to the industry standards detailed in Table 25. Table 25. Industry Standards Standard URL for Information and Specifications ACPI Advance Configuration and Power Interface Specification, v2...