Page 2 - 5 Volvo Drive
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2003 Crestron Electronics, Inc.
Page 3 - Contents
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 Contents • i Contents System Power Supply: C2N-SPWS300 1 Introduction...................................................................................................................1 Features and Functions ........................
Page 5 - Introduction; Features and Functions; Functional Summary; Channel Versus System Power Capabilities
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 1 System Power Supply: C2N-SPWS300 Introduction Features and Functions The C2N-SPWS300 is a 300-watt system power supply designed for large Cresnet control systems (herein referred to as Cresne...
Page 6 - Powering the Unit; The C2N-SPWS300 is shipped with two power cable assemblies. One is; PWR ON Position
System Power Supply Crestron C2N-SPWS300 2 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 Powering the Unit NOTE: The C2N-SPWS300 is shipped with two power cable assemblies. One is supplied for standard 120 VAC, 60 Hz as available in the United States. The other has three un-termina...
Page 7 - System Details; Specifications; C2N-SPWS300 Specifications; SPECIFICATION DETAILS
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 3 Pressing a RESET button during normal operations shuts off a channel for as long as the button is held down. If the button is released, the channel turns on. System Details In the event that th...
Page 8 - Physical Description; control system when the power switch is in the POWER OFF; Ports
System Power Supply Crestron C2N-SPWS300 4 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 Physical Description The C2N-SPWS300, shown after this paragraph, is housed in a sturdy 1/8-inch black anodized aluminum enclosure. A power selection switch and pigtail input power cable with a...
Page 9 - C2N-SPWS300 Physical Views; Pushbuttons
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 5 C2N-SPWS300 Physical Views 12.75 in (32.39 cm) 13.25 in (33.66 cm) 3.29 in (8.36 cm) 5.19 in (13.18 cm) 4.00 in (10.16 cm) 3.00 in (7.62 cm) Each power supply channel (1 through 8) has a green ...
Page 10 - SETUP LED and Pushbutton; for detailed information.; Industry Compliance; Setup; System Requirements
System Power Supply Crestron C2N-SPWS300 6 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 SETUP LED and Pushbutton The C2N-SPWS300 is TSID ready. The SETUP pushbutton and its associated LED located on the front panel are used for setup of the unit’s network ID during the initial con...
Page 11 - Network Wiring; do so could cause equipment damage or void the Crestron warranty.; WIRE GAUGE
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 7 Network Wiring CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. NOTE: When installing network wirin...
Page 12 - Identity Code; NOTE; Current Network Devices
System Power Supply Crestron C2N-SPWS300 8 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 Identity Code NOTE: The C2N-SPWS300 can be polled in Cresnet while the power switch is in either position as long as the appropriate data signal (Y & Z) connections are made to any of the 1...
Page 13 - Set Net ID by TSID; “Set Net ID by TSID” Window
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 9 7. Click Set ID to initiate the change. This will display the "ID command has been sent" window. 8. In the "Command Complete" window, click OK . 9. In the Current Network Device...
Page 14 - OK; Serial Number to TSID Conversion; Functions | Serial Number; TSID Conversion Tool; ÅÆ
System Power Supply Crestron C2N-SPWS300 10 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 is similar to the report produced by pressing F4 (Report Network Devices); the first eight digits of each line constitute the TSID number (hexadecimal form of the serial number). 5. As you ent...
Page 15 - Rack Mounting; To prevent bodily injury when mounting or servicing this unit in a; Hardware Hookup; Utilize the signals available from the C2N-SPWS300 SIMPL Windows; Hookup Preparation; are utilized and loads are distributed as evenly as possible.
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 11 Rack Mounting WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, take special precautions to ensure that the system remains stable. The following guidelines are ...
Page 16 - Never connect multiple C2N-SPWS300s in parallel.
System Power Supply Crestron C2N-SPWS300 12 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 C2N-SPWS300 (PWR ON Position), Hardware Hookup NETWORK DATA LINK TO ADDITIONAL EXPANSION POWER SUPPLY, C2N-SPWS300 OR CNPWS-75 DAISY CHAIN METHOD NET NET 24 Z Y G Z Y G 24 POWER EXPANSION (NET...
Page 17 - Hookup Procedure; Connect each network unit to the appropriate network connector.; Diagnostics | Report Network Devices
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 13 C2N-SPWS300 (PWR OFF SLAVE Position), Hardware Hookup NETWORK DATA LINK TO ADDITIONAL EXPANSION POWER SUPPLY, C2N-SPWS300 OR CNPWS-75 DAISY CHAIN METHOD NET NET 24 Z Y G Z Y G 24 POWER EXPANSI...
Page 18 - Programming Software; PRO2 System View
System Power Supply Crestron C2N-SPWS300 14 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 Programming Software Have a comment about Crestron software? Direct software related suggestions and/or complaints to Crestron via email ([email protected]). Do not forward any queries to ...
Page 19 - System Views; C2Net-Device Slot in Configuration Manager; Device Library; Setting the Net ID in Device Settings; Net
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 15 The System Views lower pane displays the PRO2 system tree. This tree can be expanded to display and configure the communications ports. Expanded PRO2 System Tree C2Net-Device Slot in Configura...
Page 20 - “Device Settings” Window for the C2N-SPWS300; C2N-SPWS300 Symbol in Programming Manager
System Power Supply Crestron C2N-SPWS300 16 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 “Device Settings” Window for the C2N-SPWS300 NOTE: SIMPL Windows automatically changes NET ID values of a device added to a program if a duplicate device or a device with the same default NET ...
Page 21 - Signal Types; In SIMPL Windows, the signal types are color-coded as follows:; Digital Signals
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 17 Signal Types Signals interconnect the various devices and logic symbols that comprise a SIMPL program. Signals can be one of three types: digital, analog, or serial. For any given signal, the ...
Page 22 - Digital Output Signal Descriptions; Digital Input Signal Descriptions; INPUT DESCRIPTION; Analog Output Signal Descriptions; OUTPUT DESCRIPTION; Example Program
System Power Supply Crestron C2N-SPWS300 18 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 C2N-SPWS300 Input/Output Signals The following tables list and give functional descriptions for the power supply outputs and inputs. Digital Output Signal Descriptions OUTPUT DESCRIPTION Chan1...
Page 23 - Uploading and Upgrading; Communication Settings; For laptops and other PCs without a built-in RS-232 port, Crestron
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 19 Uploading and Upgrading Assuming a PC is properly connected to the entire system, Crestron programming software allows the programmer to upload programs to the system after their development. ...
Page 24 - Typical Connection Diagram when Uploading a Project; Viewport; Refer to the following figure. From the Viewport menu, select; Communications settings; “Port Settings” window.; button to save the settings and close the window.
System Power Supply Crestron C2N-SPWS300 20 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 Typical Connection Diagram when Uploading a Project 1. Open the Crestron Viewport. Either launch the stand-alone version of Viewport, or start SIMPL Windows and from the menu bar, select Tools...
Page 25 - “Port Settings” Window; Diagnostics | Establish; Uploading a SIMPL Windows Program; Upload via SIMPL Windows; Open; Upload via Crestron Viewport
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 21 “Port Settings” Window NOTE: Different control systems may require different communication settings. Refer to each control system’s Operations Guide for proper communication settings. NOTE: Th...
Page 26 - File Transfer | Send Program; File Transfer | Send Program Command; Browse; What to Send; Send Program; “Send Program” Window; Diagnostics | Report Program Information
System Power Supply Crestron C2N-SPWS300 22 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 2. As shown after this step, select File Transfer | Send Program (alternatively, press Alt+P ) from the Viewport menu. File Transfer | Send Program Command 3. The “Send Program” window appears...
Page 27 - Firmware Upgrade; File Transfer | Load Network Device; File Transfer | Load Network Device Command; “Select Network ID” Window
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 23 Firmware Upgrade A firmware upgrade file has the extension .csf. To take advantage of all the C2N-SPWS300 features, it is important that the unit contains the latest firmware available. Theref...
Page 28 - “Open” Window; to begin the transfer.
System Power Supply Crestron C2N-SPWS300 24 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 “Open” Window 4. Browse to the desired .upg file and click Open to begin the transfer.
Page 29 - Problem Solving; Troubleshooting; C2N-SPWS300 Troubleshooting
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 25 Problem Solving Troubleshooting The table below provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service repres...
Page 30 - Further Inquiries
System Power Supply Crestron C2N-SPWS300 26 • System Power Supply: C2N-SPWS300 Operations Guide - DOC. 8190 Further Inquiries If, after reviewing this Operations Guide for the C2N-SPWS300, you cannot locate specific information or have questions, please take advantage of Crestron's award winning cus...
Page 31 - Return and Warranty Policies; Merchandise Returns / Repair Service
Crestron C2N-SPWS300 System Power Supply Operations Guide – DOC. 8190 System Power Supply: C2N-SPWS300 • 27 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warran...