Page 2 - 5 Volvo Drive
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Page 3 - Safety Information; from uninterrupted service during this process.; Operations & Installation Guide – DOC. 6635A
Crestron CEN-UPS1250 Uninterruptible Power Supply Safety Information Read this manual Read all of the safety and operating instructions before installing and operating this device. Keep this manual Retain this manual and all of the safety information that came with this device. Warnings Comply with ...
Page 4 - switch or disconnect the AC power; ii
Uninterruptible Power Supply Crestron CEN-UPS1250 Other Grounding This device provides a grounding lug on the rear panel for grounding the device to an external transient voltage surge suppression (TVSS) device. Ensure these ground connections are made in accordance with the instructions provided wi...
Page 5 - Contents; Uninterruptible Power Supply: CEN-UPS1250
Crestron CEN-UPS1250 Uninterruptible Power Supply Contents Safety Information ...................................................................................................................... i Uninterruptible Power Supply: CEN-UPS1250 1 Introduction ...............................................
Page 7 - Introduction; Features and Functions; Uninterruptible Power Supply; Engineered by APC; Pure Sine Wave Battery Backup
Crestron CEN-UPS1250 Uninterruptible Power Supply Uninterruptible Power Supply: CEN-UPS1250 Introduction Features and Functions • UPS and power conditioning – Engineered by APC ® • 2-Series control system integration • Centralized management via RoomView ® software • Battery backup and power control...
Page 8 - Managed Power Control
Uninterruptible Power Supply Crestron CEN-UPS1250 if excessive line noise or distortion is detected, ensuring optimum performance of sensitive video and audio equipment during momentary power glitches. When running on battery backup, the CEN-UPS1250 can power a rack full of equipment for several min...
Page 9 - RoomView; Specifications; SPECIFICATION DETAILS
Crestron CEN-UPS1250 Uninterruptible Power Supply RoomView ® and Control System Integration Monitoring and operation of the CEN-UPS1250 extends beyond its front panel, providing direct communication with Crestron’s RoomView Remote Asset Management Software as well as with Ethernet enabled 2-Series c...
Page 11 - Physical Description
Crestron CEN-UPS1250 Uninterruptible Power Supply Physical Description This section provides information on the connections, controls and indicators available on your CEN-UPS1250. CEN-UPS1250 Front View CEN-UPS1250 Rear View Operations & Installation Guide – DOC. 6635A Uninterruptible Power Supp...
Page 13 - INDICATORS; CURRENT DEVICES
Crestron CEN-UPS1250 Uninterruptible Power Supply CEN-UPS1250 Overall Dimensions (Rear View) 16 17 18 19 14 15 20 21 22 23 24 25 26 27 Connectors, Controls & Indicators # CONNECTORS, CONTROLS & INDICATORS DESCRIPTION 1 ON LINE LED (1 green) Indicates a working connection to the control syste...
Page 15 - When resetting the; , push the button in quickly and; Do not; hold the; Circuit Breaker; button in. Failure to comply
Crestron CEN-UPS1250 Uninterruptible Power Supply Connectors, Controls & Indicators (Continued) # CONNECTORS, CONTROLS & INDICATORS DESCRIPTION 21 TELCO IN – (1) 4-pin RJ-11 female; Dual line telephone connection. OUT – (2) 4-pin RJ-11 female; Protected dual line telephone/modem device conne...
Page 16 - Industry Compliance; Reorient or relocate the receiving antenna.
Uninterruptible Power Supply Crestron CEN-UPS1250 Industry Compliance This unit has been manufactured to comply with the following Standards for Safety in the United States, Canada and Mexico. NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditi...
Page 17 - Setup; Ethernet; for; Identity Code; When setting the IP ID, consider the following:; Supplied Hardware; DESCRIPTION PART; Installation
Crestron CEN-UPS1250 Uninterruptible Power Supply Setup Ethernet Unlike other Crestron network devices, the CEN-UPS1250 does not use Cresnet for communications between the device and the control system. The CEN-UPS1250 requires the use of a high-speed Ethernet connection for control system communi...
Page 18 - The CEN-UPS1250 should not be lifted or moved using the two
Uninterruptible Power Supply Crestron CEN-UPS1250 by firmly grasping both sides of the unit in the middle. Failure to comply may result in personal injury and/or damage to the equipment. WARNING: The CEN-UPS1250 should not be lifted or moved using the two handles on the front panel. These are intend...
Page 19 - Rack mount ears should; Front
Crestron CEN-UPS1250 Uninterruptible Power Supply NOTE: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). 1. Install the rack mount rails (refer ...
Page 21 - Hardware Hookup; Connect the Device
Crestron CEN-UPS1250 Uninterruptible Power Supply Inserting and Connecting the Battery The CEN-UPS1250 is shipped with the internal battery pack disconnected. The front bezel of the unit is also not attached to the unit when it is shipped. This procedure is for connecting the battery when the front ...
Page 22 - Ground Wire Connections
Uninterruptible Power Supply Crestron CEN-UPS1250 When making connections to the CEN-UPS1250, consider that the included AC cable cannot be extended. Hardware Connections for the CEN-UPS1250 INPUT 120V 47-63 Hz 12A : MAIN POWER INPUT GROUND ENV PROBE : FROM EXTERNAL TEMPERATURE/RH SENSOR CABLE IN: F...
Page 23 - Programming Software; Have a question or comment about Crestron software?; Earliest Version Software Requirements for the PC; Configuration Manager
Crestron CEN-UPS1250 Uninterruptible Power Supply Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestro...
Page 25 - Program Manager; Example Program
Crestron CEN-UPS1250 Uninterruptible Power Supply “CEN-UPS1250 Device Settings” Window • The ID code specified in the SIMPL Windows program must match the IP ID of each unit. Refer to “Identity Code” on page 11. Program Manager Program Manager is the view where programmers “program” a Crestron contr...
Page 26 - Uploading and Upgrading; Establishing Communication; Model
Uninterruptible Power Supply Crestron CEN-UPS1250 Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necess...
Page 27 - Functions | Ethernet Addressing; Programs and Firmware; SIMPL Windows; Functions | Firmware...; Program Checks; Functions
Crestron CEN-UPS1250 Uninterruptible Power Supply • Enter the IP address, IP mask and default router of the CEN-UPS1250 via the Crestron Toolbox ( Functions | Ethernet Addressing ); otherwise enable DHCP. • Confirm Ethernet connections between CEN-UPS1250 and PC. If connecting through a hub or route...
Page 28 - Operation; Performing the System Test; CRESTRON; POWER CONDITIONER; BANK; panel outlets marked; DELAY
Uninterruptible Power Supply Crestron CEN-UPS1250 Operation Performing the System Test Before connecting equipment to the CEN-UPS1250, ensure the unit is functional by connecting the AC power cord provided with the unit to the AC power connector on the rear panel and then to an AC outlet. Also, ensu...
Page 29 - BATT IN USE; LED is also lit during this test.
Crestron CEN-UPS1250 Uninterruptible Power Supply “SELFTEST IS ON…; ON-LINE SELFTEST” Screen SELFTEST IS ON…ON-LINE SELFTEST The “SELFTEST IS ON; ON-BATTERY SELFTEST” screen indicates the on-battery selftest is active with the unit internally switched to derive power from the internal battery pack (...
Page 30 - Status and Informational Screens; button on the front panel.; STATUS; button until the; STATUS; button for
Uninterruptible Power Supply Crestron CEN-UPS1250 Status and Informational Screens The following paragraphs describe the various status and informational screens that are available with the CDN-UPS1250. These are accessed by using the STATUS button on the front panel. NOTE: For your convenience, you...
Page 31 - At times, the frequency values on this screen may not match. This is; LAN; port on the rear panel.
Crestron CEN-UPS1250 Uninterruptible Power Supply connected to the unit. Loads of less than 5% of rates load (63 Watts) will be displayed as <5%. “SYSTEM LOAD: XXXW; LOAD: XXX%” Screen SYSTEM LOAD: <63WLOAD: <5% The “INPUT VOLTAGE: XXXV; OUTPUT VOLTAGE: XXXV” screen displays the actual inpu...
Page 32 - Setup Screens; SETUP
Uninterruptible Power Supply Crestron CEN-UPS1250 “BANK3 (ANALOG):ON; BANK4 (HI AMP):ON” Screen BANK3 (ANALOG):ONBANK4 (HI AMP):ON The model number and serial number screen displays information about your CEN-UPS1250. “MODEL #; S/N” Screen MODEL#:CEN-UPS 1250S/N:PB0707130791 The “ENV. TEMPERATURE” s...
Page 33 - LOW
Crestron CEN-UPS1250 Uninterruptible Power Supply 10. Battery Replacement Date 11. Do Quick Selftest 12. Do Runtime Calculation 13. Display Beep Test 14. Screen Saver On/Off 15. Reset To Default AUDIBLE ALARM setting – When the alarm is set to ON, it indicates an abnormal condition with the power or...
Page 35 - LOW BATT; LED on the front panel whenever the battery pack’s; button to move the cursor to the day; button to move the cursor to the year field. Set the year using the
Crestron CEN-UPS1250 Uninterruptible Power Supply “OUTLET DELAY2” Screen OUTLET DELAY2:5SECPRESS TO CHANGE LOWBATWARNING setting – This screen lets you set the unit to sound an alarm and illuminate the LOW BATT LED on the front panel whenever the battery pack’s estimated runtime remaining drops to o...
Page 36 - display when the system load is less than 5%.; The screen illustrations in this section show default values.
Uninterruptible Power Supply Crestron CEN-UPS1250 “DO RUNTIME CAL” Screen DO RUNTIME CAL:NOPRESS TO CHANGE DISPLAY-BEEP TEST setting – This function allows you to force the unit to perform display and beep tests. Simply press either the up or down arrow button. This will cause all the indicators and...
Page 37 - Problem Solving; Troubleshooting; TROUBLE
Crestron CEN-UPS1250 Uninterruptible Power Supply Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CEN-UPS1250 Troubleshooting TROUBLE POSSIBLE...
Page 38 - Reference Documents; product manuals arranged in alphabetical order by model number.; DOCUMENT TITLE; Further Inquiries; ) for a listing of Crestron worldwide offices.; Future Updates
Uninterruptible Power Supply Crestron CEN-UPS1250 Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website ( www.crestron.com/manuals ). This link will provide a list of product manuals arranged in alphabetical order by model number...
Page 39 - Return and Warranty Policies; Merchandise Returns / Repair Service
Crestron CEN-UPS1250 Uninterruptible Power Supply Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRE...