Table of Contents:
- Page 2 – SPECIFICATIONS
- Page 3 – INSTALLATION REQUIREMENTS for ICAP1 B LD and WHIPPER B:; OFF; DISPENSER OPERATION; FILLING
- Page 4 – I. INSTALLATION INSTRUCTIONS; can be moved for cleaning underneath.; So keep Reservoir Tank full; III. PRIMING INSTRUCTIONS FOR ICAP1 POUROVER; PRIMING - AUTOFILL
- Page 6 – DRINK STRENGTH ADJUSTMENTS
- Page 8 – TROUBLESHOOTING PROCEDURE
- Page 9 – DESCRIPTION AND LOCATION OF COMPONENTS
- Page 17 – DOOR UNIT
1
GOURMET HOT BEVERAGE DISPENSER
Models:
ICAP1
ICAP1-P
ICAP-MINI
WHIPPER
WHIPPER MINI
OPERATIONAL MANUAL
Specifications
Installation & Operating Instructions
Adjustments
Care & Maintenance
Trouble Shooting Guide
Wiring Diagram
Parts List
Cecilware sells value...
Worldwide.
43-05 20th Avenue, Long Island City, NY 11105
·
718-932-1414
FAX:
·
718-932-7860
THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WIT H
THE APPLICABLE FED ERAL, STATE, OR LOCAL PLUMBING
CODES HAVING JURISDICTION.
IN ADDITION:
1. A QUICK DISCONN ECT WAT ER CONN ECTION OR
ENOUG H EXTRA COILED TUBING (AT LEAST 2X
THE DEPTH OF THE UNIT) SO THAT THE MACHINE
CAN BE MO VED FOR CLEANING UNDERNEAT H.
2. AN APPRO VED BACK FLOW PREVENTION DEVICE,
SUCH AS A DO UBLE CHECK VALVE TO BE INSTALLED
BETWEEN THE MACHINE AND THE W ATER S UPPLY.
NA64A 6/99
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 MODELS: ICAP 1 B LD WHIPPER B ICAP1 B LD ICAP B LD WHIPPER B STORAGE CAPACITY Hopper Capacity [lb.] 8 8 8 8 8 Tank Capacity [gal.] 1.5 1.5 1.5 0 .6 0.6 PRODUCTION CAPACITY Continuous Draw Rate [oz/drinks/min.] [drinks / hour] 2 (6 oz.) drinks/min 120 2 (6 oz.) . 120 2 (6 oz.) 120 2 (6 oz.) 60 2 (6...
3 INSTALLATION REQUIREMENTS for ICAP1 B LD and WHIPPER B: THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE APPLICABLE FEDERAL, STATE, OR LOCAL PLUMBING CODES HAVING JURISDICTION. IN ADDITION: 1. A QUICK DISCONNECT WATER CONNECTION OR ENOUGH EXTRA COILED TUBING (AT LEAST 2X THE DEPTH OF THE UNIT)...
4 START UP INSTRUCTIONS FOR ICAP1 POUROVER CAPPUCCINO DISPENSER – see ill. 3 I. INSTALLATION INSTRUCTIONS This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition: 1. A quick disconnect water connection or enough extra c...