Carrier 2025 - Manual

Carrier 2025

The installation manual for Carrier’s GAPA Infinity™ air purifiers (models 1625 and 2025) covers essential setup, safety, and integration with HVAC systems. Key topics include proper placement relative to furnaces–such as upflow, downflow, or horizontal configurations–and electrical wiring requirements (e.g., 115V/60Hz). The guide emphasizes hazard prevention, like avoiding cut hazards during installation, and provides diagrams for mounting orientations and component assembly. Maintenance aspects, such as cartridge replacement, are also addressed alongside detailed specifications on airflow, efficiency ratings, and physical dimensions.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 1 – Installation Overview and Safety for Air Purifier
  • Page 2 – Installation Placement and Component Requirements
  • Page 3 – Air Purifier Mounting Orientation
  • Page 4 – Cabinet Mounting Procedure
  • Page 5 – Electrical Wiring and Power Connection
  • Page 6 – Operation, Wiring, and Maintenance Procedures
  • Page 7 – Troubleshooting and Cartridge Replacement
  • Page 8 – Product Specifications and Dimensions
  • Page 9 – Five-Year Limited Warranty and Service Information
Loading the manual
Page 1

1

GAPA

Infinity

t

Air Purifier

Sizes 1625 and 2025

Installation, Start --- Up, and

Operating Instructions

NOTE

: Read the entire instruction manual before starting the

install.

This symbol

indicates a change since the last issue.

TABLE OF CONTENTS

Page

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . .

INSTALLATION

3--5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

6

. . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

8

. . . . . . . . . . . . . . . .

WARRANTY

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Infinity

t

Air Purifier for your

home comfort system! The Infinity

t

Air Purifier is proven to

remove and kill airborne germs and allergens, including viruses,

bacteria, and mold spores. The Infinity

t

Air Purifier is a

cornerstone of Carrier’s Healthy Home Solutions for providing

healthier, cleaner air in your home.

HOW IT WORKS

The Infinity

t

Air Purifier provides extremely high filtration

performance while killing captured contaminants, including

viruses, bacteria, and mold spores. The Infinity

t

Air Purifier

treats the entire air--stream through a state of the art, three--stage

process, exclusive to Carrier.
I n st a g e o n e , t h e p a r t i c l e s a r e e l e c t r i c a l l y c h a rg e d b y a

precision--point ionization array as they enter the Infinity

t

Air

Purifier.
In stage two, the charged particles are electrically attracted to

the air purification cartridge, which is located within an electric

field.
In stage three, captured particles are killed by electrical current

flow and ion bombardment.

A05265

Fig. 1 -- GAPA Unit

SAFETY CONSIDERATIONS

I m p r o p e r i n s t a l l a t i o n , a d j u s t m e n t , a l t e r a t i o n , s e r v i c e ,

maintenance, or use can cause explosion, fire, electrical shock

or other conditions which may cause personal injury or property

damage. Consult a qualified installer, service agency, or your

d i s t r i b u t o r o r b r a n c h f o r i n f o r m a t i o n o r a s s i s t a n c e . T h e

qualified installer or agency must use factory authorized kits or

a c c e s s o r i e s w h e n m o d i f y i n g t h i s p r o d u c t . R e f e r t o t h e

individual instructions packaged with the kits or accessories

when installing.
Follow all safety codes. Wear safety glasses and work gloves.

Have fire extinguisher available. Read these instructions

thoroughly and follow all warning or cautions attached to the

unit. Consult local building codes and National Electrical Code

(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol

. When you see this symbol on the unit

and in instructions or manuals, be alert to the potential for

p e r s o n a l i n j u r y. U n d e r s t a n d t h e si g n a l wo r d s D A N G E R ,

WARNING, and CAUTION. These words are used with the

safety -- alert symbol. DANGER identifies the most serious

hazards which

will

result in severe personal injury or death.

WARNING signifies hazards which

could

result in personal

injury or death. CAUTION is used to identify unsafe practices

which

may

result in personal injury or product and property

damage. NOTE is used to highlight suggestions which

will

result in enhanced installation, reliability, or operation.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Carrier
Model
2025
Document type
Manual
Language(s)
English
Pages
10
File size
1.9 MB
Format
PDF

Summary

Page 1 - Installation Overview and Safety for Air Purifier

Installation, start-up, and operating instructions, unit explanation, safety considerations, hazard symbols, and unit diagrams.

Page 2 - Installation Placement and Component Requirements

Guidelines for positioning the air purifier relative to air conditioning and humidifier placement, electrical power requirements, transition fittings, and component diagrams.

Page 3 - Air Purifier Mounting Orientation

Steps for installing the unit, checking components, identifying mounting locations, safety warnings regarding cut hazards, and orientation guidance for different furnace types.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.