The installation manual for Carrier’s GAPA Infinity™ air purifiers (models 1625 and 2025) covers essential setup, safety, and integration with HVAC systems. Key topics include proper placement relative to furnaces–such as upflow, downflow, or horizontal configurations–and electrical wiring requirements (e.g., 115V/60Hz). The guide emphasizes hazard prevention, like avoiding cut hazards during installation, and provides diagrams for mounting orientations and component assembly. Maintenance aspects, such as cartridge replacement, are also addressed alongside detailed specifications on airflow, efficiency ratings, and physical dimensions.
Table of Contents:
- Page 1 – Installation Overview and Safety for Air Purifier
- Page 2 – Installation Placement and Component Requirements
- Page 3 – Air Purifier Mounting Orientation
- Page 4 – Cabinet Mounting Procedure
- Page 5 – Electrical Wiring and Power Connection
- Page 6 – Operation, Wiring, and Maintenance Procedures
- Page 7 – Troubleshooting and Cartridge Replacement
- Page 8 – Product Specifications and Dimensions
- Page 9 – Five-Year Limited Warranty and Service Information
1
GAPA
Infinity
t
Air Purifier
Sizes 1625 and 2025
Installation, Start --- Up, and
Operating Instructions
NOTE
: Read the entire instruction manual before starting the
install.
This symbol
→
indicates a change since the last issue.
TABLE OF CONTENTS
Page
INTRODUCTION
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HOW IT WORKS
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . . . . . .
APPLICATION CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . .
INSTALLATION
3--5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START--UP AND OPERATION
6
. . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SPECIFICATIONS AND DIMENSIONS
8
. . . . . . . . . . . . . . . .
WARRANTY
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
Congratulations for selecting the Infinity
t
Air Purifier for your
home comfort system! The Infinity
t
Air Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Infinity
t
Air Purifier is a
cornerstone of Carrier’s Healthy Home Solutions for providing
healthier, cleaner air in your home.
HOW IT WORKS
The Infinity
t
Air Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Infinity
t
Air Purifier
treats the entire air--stream through a state of the art, three--stage
process, exclusive to Carrier.
I n st a g e o n e , t h e p a r t i c l e s a r e e l e c t r i c a l l y c h a rg e d b y a
precision--point ionization array as they enter the Infinity
t
Air
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
A05265
Fig. 1 -- GAPA Unit
SAFETY CONSIDERATIONS
I m p r o p e r i n s t a l l a t i o n , a d j u s t m e n t , a l t e r a t i o n , s e r v i c e ,
maintenance, or use can cause explosion, fire, electrical shock
or other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
d i s t r i b u t o r o r b r a n c h f o r i n f o r m a t i o n o r a s s i s t a n c e . T h e
qualified installer or agency must use factory authorized kits or
a c c e s s o r i e s w h e n m o d i f y i n g t h i s p r o d u c t . R e f e r t o t h e
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the unit
and in instructions or manuals, be alert to the potential for
p e r s o n a l i n j u r y. U n d e r s t a n d t h e si g n a l wo r d s D A N G E R ,
WARNING, and CAUTION. These words are used with the
safety -- alert symbol. DANGER identifies the most serious
hazards which
will
result in severe personal injury or death.
WARNING signifies hazards which
could
result in personal
injury or death. CAUTION is used to identify unsafe practices
which
may
result in personal injury or product and property
damage. NOTE is used to highlight suggestions which
will
result in enhanced installation, reliability, or operation.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Carrier
- Model
- 2025
- Document type
- Manual
- Language(s)
- English
- Pages
- 10
- File size
- 1.9 MB
- Format
Summary
Installation, start-up, and operating instructions, unit explanation, safety considerations, hazard symbols, and unit diagrams.
Guidelines for positioning the air purifier relative to air conditioning and humidifier placement, electrical power requirements, transition fittings, and component diagrams.
Steps for installing the unit, checking components, identifying mounting locations, safety warnings regarding cut hazards, and orientation guidance for different furnace types.