Broan QTRE080R - Manual

Broan QTRE080R

Broan QTRE080R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 3 – NEW CONSTRUCTION INSTALLATION; INSTALL DUCTWORK; INSTALL ELECTRICAL WIRING
  • Page 4 – INSTALL THUMBSCREW; EXISTING CONSTRUCTION INSTALLATION; REMOVE EXISTING FAN
  • Page 6 – SERVICE PARTS
Loading the manual

Page 1

MODEL QTRE080R

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the address

or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service

panel and lock the service disconnecting means to prevent

power from being switched on accidentally. When the service

disconnecting means cannot be locked, securely fasten a

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes

and standards, including fire-rated construction codes and

standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment

manufacturer’s guideline and safety standards such as those

published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE), and the local code authori-

ties.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to

a GFCI (Ground Fault Circuit Interrupter) - protected branch

circuit (ceiling installation only).

8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power

unit.

3. Please read specification label on product for further informa-

tion and requirements.

ULTRA SILENT

TM

VENTILATION FAN

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

WARRANTY

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appear-

ance - lower or remove grille and vacuum interior of unit with the

dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the

motor bearings are making excessive or unusual noises, replace

the motor with the exact service motor. The impeller should also

be replaced.

OPERATION

Use an on/off switch or speed control to operate this ventilator. See
“Connect Wiring” for details. Use of speed controls other than the
Broan Models 78V and 78W may cause a motor humming noise.

To register this product visit:

www.broan.com

BROAN THREE YEAR LIMITED WARRANTY

Broan warrants to the original consumer purchaser of its products that such

products will be free from defects in materials or workmanship for a period

of three years from the date of original purchase. THERE ARE NO OTHER

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR

A PARTICULAR PURPOSE.
During this three-year period, Broan will, at its option, repair or replace,

without charge, any product or part which is found to be defective under

normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP

STARTERS AND TUBES. This warranty does not cover (a) normal main-

tenance and service or (b) any products or parts which have been subject

to misuse, negligence, accident, improper maintenance or repair (other

than by Broan), faulty installation or installation contrary to recommended

installation instructions.
The duration of an implied warranty is limited to the three-year period as

specified for the express warranty. Some states do not allow limitation

on how long an implied warranty lasts, so the above limitation may not

apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OP-

TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY

UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-

DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF

OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some

states do not allow the exclusion or limitation of incidental or consequential

damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other

rights, which vary from state to state. This warranty supersedes all prior

warranties.
To qualify for warranty service, you must (a) notify Broan at the address

or telephone number stated below, (b) give the model number and part

identification and (c) describe the nature of any defect in the product or

part. At the time of requesting warranty service, you must present evidence

of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin

www.broan.com 800-558-1711

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - NEW CONSTRUCTION INSTALLATION; INSTALL DUCTWORK; INSTALL ELECTRICAL WIRING

Page 3 MODEL QTRE080R INSTALL MOUNTING FRAME & HOUSING 1. Hold one side of the mounting frame so the tabs touch the bottom edge of the framing member. Nail or screw mounting frame in place. Extend the mounting frame to the opposite framing member, and nail or screw in place. 2. Snap the duct con...

Page 4 - INSTALL THUMBSCREW; EXISTING CONSTRUCTION INSTALLATION; REMOVE EXISTING FAN

Page 4 MODEL QTRE080R INSTALL THUMBSCREW & GRILLE 6. Install thumbscrew through flange of motor plate as shown. 7. Install ceiling material. Cut out around housing.8. Squeeze grille springs and insert them into slots on each side of housing. Push grille against ceiling. EXISTING CONSTRUCTION INS...

Page 6 - SERVICE PARTS

Page 6 MODEL QTRE080R SERVICE PARTS Key No. Part No. Description 1 97018118 Housing 2 97016449 Duct Connector-4” 3 98010102 Wiring Plate 4 99170245 Screw, #8-18 X .375 (7 Req.) 5 97018010 Wire Panel/Harness Assembly 6 97017853 Blower Assembly 7 97016497 Grille Assembly (includes key no. 8) 8 9914019...

Other Broan Models