Broan BWP1304SS - User Manual
Broan BWP1304SS Range Hood – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – CLEANING & MAINTENANCE; MOTOR; OPERATION
- Page 3 – INSTALL THE DUCTWORK; MEASURE THE INSTALLATION
- Page 4 – CONT; INSTALL THE WIRING
- Page 5 – INSTALL THE HOOD MOUNTING BRACKET; WALL STUDS
- Page 6 – INSTALL THE HOOD
- Page 8 – NON-DUCT KIT MODEL ARKBWP CONTENTS
- Page 10 – SERVICE PARTS; BWP1 Series; BWP2 Series
- Page 11 – WARRANTY
- Page 12 – LIRE CES DIRECTIVES ET LES CONSERVER; POUR; INSTALLATEUR : VEUILLEZ LAISSER CE GUIDE AU PROPRIÉTAIRE.; AVERTISSEMENT; Pour enregistrer ce produit,
- Page 13 – NETTOYAGE ET ENTRETIEN; MOTEUR; FONCTIONNEMENT
- Page 14 – POSE DU CONDUIT; MESURES DE L’INSTALLATION
- Page 15 – SUITE; INSTALLATION DU CÂBLAGE
- Page 16 – INSTALLATION DU SUPPORT DE MONTAGE DE LA HOTTE; MONTANTS; po
- Page 17 – INSTALLATION DE LA HOTTE
- Page 19 – CONTENU DE L’ENSEMBLE POUR HOTTE
- Page 21 – PIÈCES DE RECHANGE; Série BWP1; Série BWP2
- Page 22 – GARANTIE
- Page 23 – LEA Y CONSERVE ESTAS INSTRUCCIONES; INSTALADOR: DEJE ESTA GUÍA CON EL PROPIETARIO DE LA VIVIENDA.; ADVERTENCIA; Para registrar este producto
- Page 24 – LIMPIEZA Y MANTENIMIENTO; FUNCIONAMIENTO
- Page 25 – INSTALE LOS CONDUCTOS; MIDA LA INSTALACIÓN
- Page 26 – CONTINUACIÓN; INSTALE EL CABLEADO
- Page 27 – INSTALE EL SOPORTE DE MONTAJE DE LA CAMPANA; MONTANTES DE PARED
- Page 28 – INSTALACIÓN DE LA CAMPANA
- Page 32 – PIEZAS DE SERVICIO; Serie BWP1
- Page 33 – GARANTÍA
MODELS BWP1244SS • BWP1304SS • BWP1364SS • BWP2244SS •
BWP2304SS • BWP2364SS • BWP2306SS • BWP2366SS
Page 1
CHIMNEY
RANGE HOOD
!
INTENDED
FOR
DOMESTIC
COOKING
ONLY
.
!
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switch on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA), the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
5. This product may have sharp edges. Be carefule to avoid
cuts and abrasions during installation or cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Do not use this unit with any other solid-state speed control
device.
9. Use only metal ductwork.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods (i.e. Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filters.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels –
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
1. For
indoor
use
only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or
unbalanced impeller, keep drywall spray, construction dust,
etc. off power unit.
4. Do not use over cooking equipment greater than 60,000
BTU/hr. as the blower motor will shut down intermittently.
5. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated.
The motor will restart when it cools down. If the motor
continues to shut off and restart, have the hood serviced.
6. The bottom of the hood MUST NOT BE LESS than 26” and
at a maximum of
36” above cooktop for best capture of
cooking impurities.
7. Two installers are recommended because of the size of
this hood.
8. To reduce risk of fire and to properly exhaust air, be sure
to duct air outside. Do not exhaust air into spaces within
walls or ceilings or into attics, crawl spaces, or garages.
9. Be careful when installing the decorative flue and hood,
they may have sharp edges.
10. Please read specification label on product for further
information and requirements.
INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER.
HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 2.
WARNING
To register this product visit:
www.broan-nutone.com or
www.broan.ca
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MODELS BWP1244SS • BWP1304SS • BWP1364SS • BWP2244SS • BWP2304SS • BWP2364SS • BWP2306SS • BWP2366SS Page 2 CLEANING & MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit. MOTOR The motor is permanently lubricated and never needs oiling. If the motor beari...
MODELS BWP1244SS • BWP1304SS • BWP1364SS • BWP2244SS • BWP2304SS • BWP2364SS • BWP2306SS • BWP2366SS Page 3 INSTALL THE DUCTWORK (Ducted Hoods Only) 1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. ...
MODELS BWP1244SS • BWP1304SS • BWP1364SS • BWP2244SS • BWP2304SS • BWP2364SS • BWP2306SS • BWP2366SS Page 4 PREPARE THE HOOD ( CONT ’ D ) For ducted installation only: Install both damper flaps inside the blower exhaust opening, ensuring the pins are top oriented. See illustration below. P INS ON TO...