Broan 755 - Manual

Broan 755

Broan 755 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – SUSPENDED CEILINGS; INSTALL THE HOUSING; New Construction
  • Page 3 – INSTALL THE DUCTWORK; CONNECT THE WIRING; Existing Construction
  • Page 4 – BULB REPLACEMENT; SERVICE PARTS
  • Page 5 – Página 5; ADVERTENCIA; LEA Y CONSERVE ESTAS INSTRUCCIONES; INSTALACIONES TÍPICAS
  • Page 6 – Página 6; INSTALACIÓN DE LA CUBIERTA; Construcción nueva
  • Page 7 – Página 7; CONEXIÓN ELÉCTRICA; Construcción existente
  • Page 8 – Página 8; USO Y CUIDADO; REEMPLAZO DEL FOCO; PIEZAS DE SERVICIO; GARANTIA
Loading the manual

Page 1

MODEL 755

DECORATIVE SERIES
CEILING VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC
S H O C K , O R I N J U RY TO P E R S O N S , O B -
SERVE THE FOLLOWING:
1. Use this unit only in the manner intended by

the manufacturer. If you have questions, con-
tact the manufacturer at the address or tele-
phone number listed in the warranty.

2. Before servicing or cleaning unit, switch power

off at service panel and lock the service dis-
connecting means to prevent power from be-
ing switched on accidentally. When the ser-
vice disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.

3. Installation work and electrical wiring must be

done by a qualified person(s) in accordance
with all applicable codes and standards, in-
cluding fire-rated construction codes and stan-
dards.

4. Sufficient air is needed for proper combus-

tion and exhausting of gases through the flue
(chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equip-
ment manufacturer ’s guideline and safety
standards such as those published by the
National Fire Protection Association (NFPA),
and the American Society for Heating, Refrig-
e r a t i o n a n d A i r C o n d i t i o n i n g E n g i n e e r s
(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do

not damage electrical wiring and other hid-
den utilities.

6. Ducted fans must always be vented to the out-

doors.

7. NEVER place a switch where it can be

reached from a tub or shower.

8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently

protected.

CAUTION

!

1. For general ventilating use only. Do not use

to exhaust hazardous or explosive materials
and vapors.

2. This product is designed for installation in

FLAT CEILINGS ONLY. Do not mount this
product in a wall.

3. The light fixture assembly must be mounted

to the fan housing assembly included with this
product. Do not mount the light fixture as-
sembly to a wiring outlet box.

4. To avoid motor bearing damage and noisy

and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.

5. Please read specification label on product for

further information and requirements.

TYPICAL INSTALLATIONS

HOUSING MOUNTED

TO ADDITIONAL FRAMING

Discharge 90

0

to joists.

HOUSING MOUNTED

DIRECTLY TO JOIST

2x6 (or larger)

Discharge parallel to joists.

HOUSING MOUNTED

TO 2x4 TRUSS

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED TO “I” JOIST

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED TO 2x4

TRUSS

Requires additional framing

for mounting tabs.

Discharge 90

0

to joists.

HOUSING MOUNTED TO “I” JOIST

Requires additional framing

for mounting tabs.

Discharge 90

0

to joists.

Installer: Leave this manual with the homeowner.

Homeowner: Use and Care information on page 4.

*

Additional framing must be a 2x6 (minimum height), at least 9-inches long.

*

*

*

*

*

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SUSPENDED CEILINGS; INSTALL THE HOUSING; New Construction

Page 2 MODEL 755 TYPICAL INSTALLATIONS(continued) SUSPENDED CEILINGS Housing hung with wires - 3-point mount. 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks. 4. Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail...

Page 3 - INSTALL THE DUCTWORK; CONNECT THE WIRING; Existing Construction

Page 3 MODEL 755 B L K V E N TS W I T C H B L U B L K W H T W H T W H T L I G H T ( W H I T E ) G R D V E N T ( B L A C K ) U N I T S W I T C H B O X L I G H TS W I T C H L I N E I N B L K R E D W H T G R D SCHEMATIC WIRING DIAGRAM SWITCH BOX LIGHT FAN DUAL CONTROL (purchase separately) WHITE BLACK ...

Page 4 - BULB REPLACEMENT; SERVICE PARTS

Page 4 MODEL 755 USE AND CARE USE AND CARE WARNING: DISCONNECT ELECTRICAL POWER SUPPLY ANDLOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVIC-ING THIS UNIT. BULB REPLACEMENT Remove glass shade. Replace bulbs as required. Replace glassshade.Use 60 Watt (maximum) candelabra base, incandescent bulbs. MOTO...