Page 3 - Contents; Page
3 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Contents Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ........................................................
Page 4 - Safety Information; READ AND SAVE THESE INSTRUCTIONS
4 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Safety Information Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. ...
Page 5 - WARNING
5 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Safety Information WARNING READ AND SAVE THESE INSTRUCTIONS WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:a) SMOTHER FLAMES ...
Page 6 - Operation
6 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Safety Information Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and...
Page 7 - List of Materials; Parts Not Supplied
7 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM List of Materials Parts Not Supplied Ducting, conduit and all installation toolsCable locking connector (if required by local codes)Extension duct coversOptional recirculating kitOptional remo...
Page 8 - Installation Instructions; Ducting Calculation Sheet
8 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Installation Instructions Duct pieces Total Equivalent number length x used = 3- 1/ 4” x 10”Rect.,straight 1 Ft. x ( ) = Ft. 3- 1/ 4” x 10”Rect. to6” roundtran...
Page 9 - For shipment and installation damages:
9 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Mounting Height, Clearance, & Ducting A minimum of 6” round duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Fle...
Page 10 - Ducting Options; Use single wall rigid metal ductwork only.
10 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Installation Instructions Ducting Options ► Use single wall rigid metal ductwork only. ► Fasten all connections with sheet metal screws and tape all joints w/...
Page 11 - ZAZ Hood Specifications; FRONT
11 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions ZAZ Hood Specifications FRONT SIDE TOP TOP SUPPORT FRAME (top view) C/L 8- 1/8 ” 7- 9/16 ” 3- 9/16 ” 13/16 ” 4- 3/16 ” 8-1/4” STANDARD min. ducted - 31- 1/2 ” min. r...
Page 12 - ZLC Hood Specifications
12 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Installation Instructions ZLC Hood Specifications FRONT SIDE TOP of HOOD TOP SUPPORT FRAME (top view) FRONT 11” 35- 7/16 ”, 41- 7/8 ” STANDARD min. ducted - 2...
Page 13 - ZRM Hood Specifications
13 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions ZRM Hood Specifications 3” STANDARD min. ducted - 28”min. recirc. - 31”max. - 39” Z1C-01RM EXTENSIONmin. ducted - 50- 1/2 ” min. recirc. - 50- 1/2 ” max. - 80” 12” A...
Page 14 - ZRE Hood Specifications
14 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Installation Instructions ZRE Hood Specifications FRONT SIDE TOP TOP SUPPORT FRAME (top view) 10- 3/8 ” 23- 15/16 ” 35- 3/16 ” 25- 9/16 ” 24- 1/2 ” 3- 9/16 ” ...
Page 15 - Electrical Supply; Electrical wiring must be done by qualified person(s) in
15 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Electrical Supply Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service e...
Page 16 - Mounting the Hood; At least two installers are required due to the weight; CAUTION; Determine mounting location on ceiling and; Side
16 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Installation Instructions Mounting the Hood At least two installers are required due to the weight and size of the hood. CAUTION 1. Determine mounting locatio...
Page 17 - Lift support frame assembly up to the ceiling; front - facing controls
17 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions 3. Lift support frame assembly up to the ceiling making sure the word “front” on the top support frame faces the front of the hood where the controls will be located...
Page 18 - If using hood in ductless recirculating
18 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Installation Instructions 8. Assemble Top Duct Covers (with louver holes) together over Top Support Frame, secure Top Duct Covers together by magnetic strips....
Page 19 - Ductless Recirculation; ZAZ
19 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood funct...
Page 20 - ICON Touch Controls
20 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Features & Controls Lights Low/High/Off Display (speed level, delay off, filter clean/change) Adjust 5 Speed Levels Power / Delay Off 1 POWER / DELAY OFF ...
Page 22 - Optional RF Remote Control; FCC Caution
22 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Features & Controls Optional RF Remote Control To enable RF remote control capabilities, the remote control accessory kit is required. The part number for...
Page 23 - RF Remote Features
23 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Features & Controls Optional RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic su...
Page 24 - Hood & Filter Cleaning; Surface Maintenance; Maintenance
24 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Hood & Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing ch...
Page 25 - LumiLight LED; Disconnect LED light quick connector.
25 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Installing the Grease Filters (FIG. K): 1. Pull down on filter latch to release the filter tabs. 2. Pull down on front of filter to remove the grease filters. Maintenance FIG. K LumiLight LED...
Page 26 - Hood must be disconnected from the main power prior to; After re-positioning the jumper and powering on the hood, the; ACTTM Conversion
26 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Hood must be disconnected from the main power prior to performing the conversion instructions listed below. Failure to do so could result in personal injury o...
Page 27 - Enabling ACTTM; To verify if your installer enabled ACTTM:
27 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM ACT™ Conversion Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. M. 2. Change plastic jumper positioning as shown in FIG...
Page 28 - Wiring Diagram
28 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Wiring Diagram Body REMARKS: CONDENSER 12.5+12.5uF 250V AC FIT AC120V 60Hz Gr een Black Whit e Black White Yellow Yellow Yello w White Yellow Blue Red Brown G...
Page 32 - Troubleshooting; Possible Problem
32 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Troubleshooting Possible Problem Possible Cause Solutions After installation, the unit doesn’t work. The power source is not turned ON. Make sure the circuit ...
Page 33 - Using the wrong size of ducting.
33 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Troubleshooting The hood is not venting out properly. Using the wrong size of ducting. Change the ducting to the correct size The hood might be hanging to high from the cook top. Adjust the d...
Page 34 - List of Parts & Accessories; Description
34 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E List of Parts & Accessories Description Part Number ZAZ Replacement Parts LumiLight LED, 6W Z0B0050 Aluminum Mesh Filter (each) 50200059 Charcoal Filter (...
Page 35 - Limited Warranty
35 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide ZEPHYRONLINE.COM Limited Warranty JAN21.0501 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products...
Page 36 - Product Registration; Prompt registration helps in more ways; IT’S IMPORTANT
36 Anzio Island, Luce Island, Roma Island, Ravenna Island Use, Care, and Installation Guide Z A Z , Z L C , Z R M , Z R E I S L A N D C O R E Product Registration Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/...
Page 37 - FR Guide d’utilisation, d’entretien et d’installation
WWW.ZEPHYRONLINE.COM MAR22.0101 Anzio Island ZAZ-M90DS ZAZ-E42DS Luce Island ZLC-M90CS ZLC-E42CS Roma Island ZRM-E36FS ZRM-E42FS Ravenna Island ZRE-M90BBSGG ZRE-E42BBSGG EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation Ai r fl ow Control Technolog y TM C
Page 39 - Table des matières
3 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Table des matières Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... ...
Page 40 - Consignes de sécurité; LISEZ ET CONSERVEZ CES INSTRUCTIONS
4 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Consignes de sécurité Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez to...
Page 41 - AVERTISSEMENT
5 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Consignes de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LE RISQUE DE BLESSURE DES PERSONNES EN CAS D’INCENDIE DE GRAISSE SUR LE HAUT DE LA CUISINIÈRE, RESPECTEZ CE QU...
Page 43 - Liste de matériel; Pièces non fournies
7 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Liste de matériel Pièces non fournies Conduits, conduits et tous les outils d’installationConnecteur de verrouillage de câble (si requis par les codes locaux)Couvertures de conduit d’extensionKit de recirculatio...
Page 44 - Instructions d’installation; Feuille de calcul pour le conduit d’aération
8 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Instructions d’installation Total = 3- 1/ 4” x 10” 1 pi x ( ) = pi 5 pi x ( ) = pi 20 pi x ( ) = pi 6”, 7”, 8”, 10” 15 pi x ( ) = pi 6”, 7”, 8”, 10” 9 pi x ( ) = pi pi 6”, 7”, 8”, 10” ...
Page 45 - Hauteur de montage, dégagement et gaine
9 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Hauteur de montage, dégagement et gaine Un conduit rond d’au moins 6 po doit être utilisé pour maintenir une efficacité maximale du débit d’air. Utilisez toujours uniquement des condu...
Page 46 - Options de conduits; NE JAMAIS évacuer l’air ni terminer de; ATTENTION
10 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Instructions d’installation Options de conduits ► Utilisez uniquement des conduits métalliques rigides à paroi simple. ► Fixez toutes les connexions avec des vis à tôle et collez tous...
Page 47 - ZAZ Spécifications de la hotte; DE FACE
11 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation ZAZ Spécifications de la hotte DE FACE CÔTÉ HAUT CADRE DE SUPPORT SUPÉRIEUR (vue de dessus) C/L 8- 1/8 po 7- 9/16 po 3- 9/16 po 13/16 po 4- 3/16 po 8-1/4 po LA NORME min. ducted - 31...
Page 48 - ZLC Spécifications de la hotte
12 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Instructions d’installation ZLC Spécifications de la hotte DE FACE CÔTÉ HAUT CADRE DE SUPPORT SUPÉRIEUR (vue de dessus) DE FACE 11 po 35- 7/16 po, 41- 7/8 po LA NORMEmin. canalisé - 2...
Page 49 - ZRM Spécifications de la hotte
13 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation ZRM Spécifications de la hotte 3 po LA NORMEmin. canalisé - 28 pomin. recirc. - 31 pomax. - 39 po Z1C-01RM EXTENSIONmin. canalisé - 50- 1/2 po min. recirc. - 50- 1/2 po max. - 80 po ...
Page 50 - ZRE Spécifications de la hotte
14 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Instructions d’installation ZRE Spécifications de la hotte DE FACE CÔTÉ HAUT CADRE DE SUPPORT SUPÉRIEUR (vue de dessus) 10- 3/8 po 23- 15/16 po 35- 3/16 po 25- 9/16 po 24- 1/2 po 3- 9...
Page 51 - Fourniture électrique; Le câblage électrique doit être effectué par des personnes
15 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Fourniture électrique Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation. N’utilisez pas de rallonge ni de fi...
Page 52 - Montage de la hotte; Au moins deux installateurs sont nécessaires en; Déterminez l’emplacement de montage au plafond; Côté
16 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Instructions d’installation Montage de la hotte Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. AVERTISSEMENT 1. Déterminez l’emplacement ...
Page 53 - Soulevez l’assemblage du cadre de support
17 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Montage de la hotte 3. Soulevez l’assemblage du cadre de support jusqu’au plafond en vous assurant que le mot « avant » sur le cadre de support supérieur fait face à l’avant de la ho...
Page 54 - Assemblez les couvercles supérieurs du conduit
18 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Instructions d’installation Montage de la hotte 8. Assemblez les couvercles supérieurs du conduit (avec des trous d’aération) sur le cadre de support supérieur, fixez les couvercles s...
Page 55 - Recirculation sans conduit
19 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Recirculation sans conduit La recirculation sans conduit est destinée aux applications où un conduit d’évacuation ne peut pas être installé. Une fois convertie, la hotte fonctionne c...
Page 56 - Fonctionnalités et commandes; Commandes tactiles ICÔNE
20 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Fonctionnalités et commandes Lumières: faible / élevée / éteinte Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) Choix de 5 vitesses Mise en marche/Arrêt à ...
Page 58 - Télécommande RF en option; Attention FCC
22 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Fonctionnalités et commandes Télécommande RF en option Pour activer les capacités de télécommande RF, le kit d’accessoires de télécommande est requis. Le numéro de pièce du kit est RC...
Page 59 - Caractéristiques de la télécommande RF
23 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Fonctionnalités et commandes Télécommande RF en option Caractéristiques de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée su...
Page 60 - Entretien; Nettoyage de la hotte et du filtre; Entretien de surface
24 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Entretien Nettoyage de la hotte et du filtre Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produ...
Page 62 - Conversion ACTTM; Technologie de contrôle du flux d’air (ACTTM)
26 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E La hotte doit être débranchée de l’alimentation principale avant d’effectuer les instructions de conversion indiquées ci-dessous. Le non-respect de cette consigne peut entraîner des b...
Page 63 - Activer ACTTM; maximum désiré du ventilateur.
27 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Conversion ACT™ Activer ACT™ Pour activer ACT™ : 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes indiquées sur la FIG. M. 2. Modifiez la position du cavalier e...
Page 64 - Schéma de câblage; Schéma
28 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Schéma de câblage Corps REMARQUES : CONDENSEUR 12.5+12.5uF 250V AC FIT AC120V 60Hz Ve rt Noir Blanc Noir Blanc Jaune Jaune Jaune Blanc Jaune Bleu Rouge Marron Gris Corps vert ZAZ-E42D...
Page 68 - Dépannage; Problème possible
32 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Dépannage Après l'installation, l'unité ne fonctionne pas. La source d'alimentation n'est pas allumée. Assurez-vous que le disjoncteur et l’appareil sont sous tension. La ligne d'alim...
Page 69 - Changer la gaine à la bonne taille
33 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Dépannage La hotte ne s'échappe pas correctement. Utilisation de la mauvaise taille de conduit. Changer la gaine à la bonne taille La hotte est peut-être suspendue trop haut de la table de cuisson. Réglez la di...
Page 70 - Liste des pièces et accessoires; La description
34 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Liste des pièces et accessoires La description Numéro d’article Pièces de rechange ZAZ LumiLight LED, 6W Z0B0050 Filtre à mailles en aluminium (chacun) 50200059 Filtre à charbon (chac...
Page 71 - Garantie limitée
35 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Garantie limitée Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produ...
Page 72 - Enregistrement du produit; C’EST IMPORTANT
36 ZAZ, ZLC, ZRM, ZRE Guide d’utilisation, d’entretien et d’installation Î L E C O R E Z A Z , Z L C , Z R M , Z R E Enregistrement du produit Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregis-trer votre nouvelle produit au www.zephyronline.com/registrat...