Page 3 - Contents
3 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Contents Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 Gene...
Page 4 - Safety Information
4 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Safety Information Your safety and the safety of others are very important. We have provided many important safety messages in this manual for...
Page 5 - WARNING
5 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Safety Information WARNING READ AND SAVE THESE INSTRUCTIONS WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting ...
Page 7 - List of Materials
7 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM List of Materials Parts Supplied Quantity Part 1 Hood 2 Safety grilles 2 LumiLight LED 1 Hardware package #6 x 1” (4) Safety Grille Screws (2) #6 x 1-1/2” (4) Wire Caps (3) 7” Round transition adapter (AK21, AK25)...
Page 8 - Installation Instructions; Ducting Calculation Sheet
8 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Installation Instructions Duct pieces Total Equivalent number length x used = 3- 1/ 4” x 10”Rect.,straight 1 Ft. x ( ) = Ft. 3- 1/ 4” x 10”Rec...
Page 11 - Ducting Options
11 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Ducting Options Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape. Fire Hazard: NEVER...
Page 12 - śŚ
Ů
12 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Installation Instructions śŚ
Ů
3 1/16 ” 1 7/16 ” 9 15/16 ” (30”) 28 1/16 ”, (36”) 34” (42”) 39 3/4 ”, (48“) 45 3/4 ” 5 1/16 ” 2 ...
Page 13 - śŞ
Ů
13 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions śŞ
Ů
(30”) 29 3/4 ”, (36”) 35 3/4 ” 14 5/8 ” 7 1/8 ” 1 7/ 8 ” 11 1/4 ” 3 3/4 ” 11 7/8 ” C/L 3 3/4 ” 6 7/8 ” elec k /o TOP SIDE FRONT BACK 8 5/8 ” 1 1/8 ” Ø 6 7/8 ” (30”) 27 ...
Page 14 - şŞ
Ů
14 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Installation Instructions şŞ
Ů
3 1/16 ” 1 7/16 ” 9 15/16 ” (30”) 27 7/8 ”, (36”) 33 7/8 ”, (42”) 39 7/8 ” 4 1/ 2 ” 1 3/16 ” 8 5/...
Page 15 - Electrical Supply
15 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Electrical Supply Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring....
Page 16 - Rectangular Vertical Ducting Preparation
16 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Installation Instructions Rectangular Vertical Ducting Preparation Ź By default the Typhoon and Hurricane are pre-configured for 7” round vert...
Page 17 - Rectangular Horizontal Ducting Preparation
17 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Rectangular Horizontal Ducting Preparation Ź By default the Typhoon and Hurricane are pre-configured for 7” round vertical ducting. Ź By default the Cyclone is pre-configured for 6” round ...
Page 19 - Mounting the Hood
19 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Installation Instructions Mounting the Hood bottom panel & lighting harness wood blocking installation screws and key-holes duct work residue cups & safety grilles electrical duct tape LumiLight LED FIG. ...
Page 21 - AK21 Capacitive Touch
21 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Features & Controls ĚŰĬĭĘĚŰĘ ĬėŰŜĘ ...
Page 22 - AK25 Electronic Touch
22 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Features & Controls 1 ħŰ ĚŰĬĘĭĚ...
Page 23 - Blower On/Off Speed Selection; AK65 Mechanical Slide
23 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Features & Controls Blower On/Off Speed Selection 1 Lights Off/Dim/Bright 2 BLOWER ON/OFF/SPEED SELECTION 0 is off, 1 is low speed, 2 is medium speed and 3 is high speed. LIGHTS OFF/DIM/BRIGHT 0 is off, 1 is ...
Page 24 - Maintenance; Hood & Filter Cleaning
24 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Maintenance Hood & Filter Cleaning Use extreme caution while cleaning the hood. Beware of blowers catching on to hair, loose clothing and...
Page 27 - LumiLight LED; Push the clip
27 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Maintenance LumiLight LED In the unlikely event that your LumiLight LED or LED light strip fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and ...
Page 28 - ACTTM Conversion; ů
ĬĻĭ; CAUTION
28 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E ACT™ Conversion ů
ĬĻĭ Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control th...
Page 29 - Enabling ACTTM
29 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. D. 2. Change plastic jumper positioning as shown in FIG. E to set the desired maximum blower...
Page 31 - Wiring Diagram; AK25C WIRING DIAGRAM; AK65C WIRING DIAGRAM
31 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Wiring Diagram AK25C WIRING DIAGRAM WHITE GREY BROWN BLUE WHITE GREY BROWN BLUE MOTOR MOTOR RED RED YELLOW YELLOW WHITE GREY BRO W N BL UE AC 120V BODY GREEN WHITE BL AC K LED LED AK65C WIRING DIAGRAM B/W B/W B/W...
Page 32 - Troubleshooting
32 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Troubleshooting Possible Problem Possible Cause Solutions After installation, the unit doesn’t work. The power source is not turned ON. Make ...
Page 33 - List of Parts & Accessories
33 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM List of Parts & Accessories Description Part Number Replacement Parts LumiLight LED, 6W (AK21 & AK25) Z0B0047 LumiLight LED, 6W (AK65) Z0B0049 Residue Cup (AK21) 56160003 Residue Cup (AK25 & AK65) 561...
Page 34 - Notes
34 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Notes
Page 35 - Limited Warranty
35 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide ZEPHYRONLINE.COM Limited Warranty 1-888-880-8368 TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer p...
Page 36 - Product Registration; Congratulations on the purchase of your; IT’S IMPORTANT
36 Typhoon, Hurricane, & Cyclone Use, Care, and Installation Guide T Y P H O O N , H U R R I C A N E & C Y C L O N E U N D E R - C A B I N E T C O R E Product Registration Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www....
Page 37 - Typhoon; FR Guide d’utilisation, d’entretien et d’installation; Hurricane
WWW.ZEPHYRONLINE.COM JAN21.0101 Typhoon AK2100CS, B, W AK2136CS, B, W AK2142CS AK2148CS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation Hurricane AK2500CS, B, W AK2536CS, B, W Cyclone AK6500CS, B, BS, W AK6536CS, B, BS, W AK6542CS Ai r fl ow Control Te c h n...
Page 39 - Table des matières
3 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Table des matières Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..........................................
Page 40 - Consignes de sécurité
4 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Consignes de sécurité Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux...
Page 41 - AVERTISSEMENT
5 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Consignes de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LE RISQUE DE BLESSURE DES PERSONNES EN CAS D’INCENDIE DE GRAISSE SUR LE HAUT DE LA CUISINIÈRE, ...
Page 43 - Liste de matériel
7 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Liste de matériel Pièces fournies Quantité Partie 1 Hotte 2 Grilles de sécurité 2 LED LumiLight 1 Trousse de quincaillerie Pièces non fournies Conduit, conduit et tous les outils d'installationAmo...
Page 44 - Instructions d’installation; Feuille de calcul pour le conduit d’aération
8 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Instructions d’installation Total = 3- 1/ 4” x 10” 1 pi x ( ) = pi 5 pi x ( ) = pi 20 pi x ( ) = pi 6”, 7”, 8”, 10” 15 pi x ( )...
Page 45 - Hauteur de montage, dégagement et gaine; po
9 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Hauteur de montage, dégagement et gaine 36 po 24 po min.32 po max.
Page 47 - Options de conduits; ATTENTION
11 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Options de conduits Ź Utilisez uniquement des conduits métalliques rigides à paroi simple. Ź Fixez toutes les connexions avec des vis à tôle et collez tous les joints ...
Page 48 - śŚ ̄
Ů
12 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Instructions d’installation śŚ¯
Ů
3 1/16 po 1 7/16 po 9 15/16 po (30 po) 28 1/16 po, (36 po) 34 po (42 po) 3...
Page 49 - śŞ ̄
Ů
13 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation śŞ¯
Ů
(30 po) 29 3/4 po, (36 po) 35 3/4 po 14 5/8 po 7 1/8 po 1 7/ 8 po 11 1/4 po 3 3/4 po C/L 3 1/16 po 6 7/8 po elec k /o DESSUS CÔTÉ DEVANT ARRIÈR...
Page 50 - şŞ ̄
Ů
14 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Instructions d’installation şŞ¯
Ů
3 1/16 po 1 7/16 po 9 15/16 po (30 po) 27 7/8 po (36 po) 33 7/8 po (42 po)...
Page 51 - Fourniture électrique
15 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Fourniture électrique Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation. N’utilisez pas de ra...
Page 52 - Préparation des conduits verticaux rectangulaires
16 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Instructions d’installation Préparation des conduits verticaux rectangulaires Ź Par défaut, le Typhoon et le Hurricane sont pr...
Page 53 - Préparation des conduits horizontaux rectangulaires
17 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Préparation des conduits horizontaux rectangulaires Ź Par défaut, le Typhoon et le Hurricane sont préconfigurés pour des conduits verticaux ronds de 7 po. Ź Par défaut,...
Page 55 - Montage de la hotte
19 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Instructions d’installation Montage de la hotte Panneau inférieur et faisceau de câbles des lumières Renforcement de bois Vis d’installation et trous en forme de serrure Conduit Plateaux collecte...
Page 57 - Fonctionnalités et commandes; AK21 Tactile capacitif
21 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Fonctionnalités et commandes Q 2 3 1 Mise en marche –Arrêt à retardement 4 Lumières: faible, moyenne, élevée 5 Indicateurs de vitesse Vitesse des ventilateurs – Augmenter Vitesse des ventilateurs...
Page 58 - AK25 Touch électronique
22 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Fonctionnalités et commandes 1 Touche de mise en marche et arrêt à retardement - La touche vous permet d’allumer et d’éteindre...
Page 59 - AK65 Glissière mécanique
23 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Fonctionnalités et commandes Ventilateur : Marche/Arrêt Choix de vitesse 1 Allumées/Veilleuse/Éteintes 2 VENTILATEUR : MARCHE/ARRÊT CHOIX DE VITESSE À 0, le ventilateur est éteint, à 1 il est à b...
Page 60 - Entretien
24 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Entretien Ů Fonction d’auto-nettoyage Les hottes Zephyr Typhoon, Hurricane et Cyclone sont sans filtre...
Page 63 - LumiLight LED et bande lumineuse LED
27 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Entretien LumiLight LED et bande lumineuse LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la ...
Page 64 - Technologie de contrôle du débit d’air (ACT TM); Conversion ACTTM
28 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Technologie de contrôle du débit d’air (ACT ™) Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuis...
Page 65 - Activer ACTTM
29 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Activer ACT™ Pour activer ACT™: 1. Avant l’installation de la hotte, accédez à la carte de circuit imprimé en suivant les étapes illustrées à la FIG. D et changez le positionnement du cavalier en...
Page 67 - Schéma de câblage; SCHÉMA
31 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Schéma de câblage AK25C SCHÉMA BLANC GRIS MARRON BLEU BLANC GRIS MARRON BLEU MOTEUR MOTEUR ROUGE ROUGE JAUNE JAUNE BL ANC GRIS MARRON BLEU AC 120V CORPS VER T BL ANC NOIR LED LED AK65C SCHÉMA NOI...
Page 68 - Dépannage
32 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Dépannage Problème possible Cause possible Solutions Après l'installation, l'unité ne fonctionne pas. La source d'alimentation...
Page 69 - Liste des pièces et accessoires
33 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Liste des pièces et accessoires La description Numéro d’article Pièces de rechange LumiLight LED, 6 W (AK21 et AK25) Z0B0047 LumiLight LED, 6 W (AK65) Z0B0049 Coupe de résidus (AK21) 56160003 Cou...
Page 70 - Remarques
34 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Remarques
Page 71 - Garantie limitée
35 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation ZEPHYRONLINE.COM Garantie limitée POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Ventilation, LLC (désigné aux présentes s...
Page 72 - Enregistrement du produit; Nous vous félicitons d’avoir acheté une produit; C’EST IMPORTANT
36 Typhoon, Hurricane, & Cyclone Guide d’utilisation, d’entretien et d’installation S O U S - A R M O I R E T Y P H O O N , H U R R I C A N E & C Y C L O N E C O R E Enregistrement du produit Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregis- tre...