Page 2 - SAFETY INSTRUCTIONS; IMPORTANT SAFETY INSTRUCTIONS; When using an electrical appliance, basic precaution; READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.; SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS D-250 98637 01/19/99 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric sh...
Page 3 - GROUNDING INSTRUCTIONS
GROUNDING INSTRUCTIONS D-250 98637 04/25/02 3 THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: The amp, hertz, and voltage are listed on thedata label found on each machine. Usingvoltages above or below those indicated on thedata label will cause serious damage to themotors. GROUNDING INSTRUCTIO...
Page 4 - OPERATIONS; before; attempting to clean it.; For hose fitting lubrication
OPERATIONS D-250 98637 0 1/15/99 4 CARPET INSPECTION: Determine precisely what areas you aregoing to clean. Note problem areas in thecarpet or tack strip. Look for loose carpet,heavily damaged areas, discolored stains,or grease spots that will require prespotting.Note the carpet type. Check the avai...
Page 5 - . When using a powder; ) Turn pump and vacuum switch to the on
OPERATIONS D-250 98637 01/19/99 5 EQUIPMENT SET-UP: 1.) Plug power cable from machine intoproperly grounded wall outlet. 2.) Turn vacuum motor switch on and offto make sure there is electrical power atmachine. 3.) Connect vac hose to machine. Slidethe swivel cuff over the outlet on the tank. 4.) Con...
Page 6 - MAINTENANCE; Vacuum out the solution tank .
MAINTENANCE D-250 98637 0 1/19/99 6 DAILY MAINTENANCE: (At the end of each working day) :1.) Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean,hot water. 2.) Vacuum out the solution tank . 3.) Rinse tank with fresh water. Periodically inspect the recovery t...
Page 7 - VACUUM MOTOR REPLACEMENT
MAINTENANCE D-250 98637 06/19/00 7 WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORMTHE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector. 4. Remove the vacuum ...
Page 8 - MAINTENANCE & TROUBLESHOOTING; D-250 PUMP MAINTENANCE
MAINTENANCE & TROUBLESHOOTING D-250 98637 1/15/99 8 D-250 PUMP MAINTENANCE Per manufacturer’s recommendations the following maintenance should be performedutilizing noted kits:1.) 500 hours-Kit 55250751 replaces the V-packing, wave washer, packing spreader and plunger guide. 2.) 500 hours-Kit 55...
Page 9 - POWER TYPE; ELECTRIC VACUUM MOTOR:; GENERAL DIMENSIONS/WEIGHT
TROUBLESHOOTING CONT. D-250 98637 06/19/00 9 Solution hose Corrosion on fittings Clean with steel wool. fitting hard to Soak in acetic acid (white vinegar). connect Lubricate lightly with silicone baselubricant. Carpet not Severe soil conditions Make several passes at right angles to getting clean. ...
Page 12 - THIS PAGE LEFT BLANK INTENTIONALLY
D250 98637 06/19/00 12 THIS PAGE LEFT BLANK INTENTIONALLY
Page 13 - RECOVERY TANK ASSEMBLY
RECOVERY TANK ASSEMBLY D-250 98637 11/07/00 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 16 16 20 21 22 23 24 25 26 27 28 29 30 16 31 32 16 19AB 33 34 35 36
Page 15 - SOLUTION TANK ASSEMBLY
SOLUTION TANK ASSEMBLY D-250 98637 11/07/00 15 1AB 2 3 4 5 6 7 8 9 10 11 8 12A 13 14 15 16 17 18 19 20 21 22 23 24 25 26A 27 29 30 31 32 33 34 36 35 37 38 8 39 40 41 42 43 44 45 46 47 48 49 50 51 38 8 46 52 53 54 8 38 55 56 57 58 38 59 8 38 60 61 62 63 64 65 66 63 67 68 41 69 70 230V 15 21 20 16 17 ...
Page 18 - SUGGESTED SPARE PARTS; DESCRIPTION
SUGGESTED SPARE PARTS D-250 98637 06/19/00 18 SUGGESTED SPARE PARTS DESCRIPTION PART NUMBER PAGE/REF FUSE 55100041 15/203 BPR KIT 55250331 15/191 THERMOSTAT 55130149 THERMOSTAT 55130143 KIT, PACKING PUMP 55250751 KIT, BEARING PUMP 55250752 KIT, VALVE PUMP 55250753 CARBON BRUSHES, VAC MOTOR 115V 1403...
Page 19 - LIMITED WARRANTY; 0 DAY WARRANTY EXTENSION AVAILABLE
ã 1999 Windsor Industries, Inc. All rights reserved. REVISED 03/24/99 LIMITED WARRANTY Windsor Industries, Inc. warrants new machines against defects in material and workmanshipunder normal use and service to the original purchaser. The warranty period is subject to theconditions stated below. 3 YEA...