Page 2 - MACHINE DATA LOG; YOUR DEALER
MACHINE DATA LOG 86038280 04/04/07 2ENG YOUR DEALER Name: __________________________________________________________________________________________________ Address: _______________________________________________________________________________________________ Phone Number: ________________________...
Page 3 - TABLE OF CONTENTS
TABLE OF CONTENTS 86038280 04/04/07 3ENG Machine Data Log. ............................................... 2 Table of Contents ................................................. 3 HOW TO USE THIS MANUAL How to use this Manual. ....................................... 1-1 SAFETY Important Safety Instru...
Page 4 - HOW TO USE THIS MANUAL; REF –
HOW TO USE THIS MANUAL 86038280 04/04/07 1-1ENG This manual contains the following sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be or...
Page 5 - IMPORTANT SAFETY INSTRUCTIONS; When using an electrical appliance, basic precaution; READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.; SAVE THESE INSTRUCTIONS
86038280 04/04/07 2-1ENG IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Co...
Page 6 - HAZARD INTENSITY LEVEL; and; and; Unless Operation Guide is Read and understood.; WARNING
HAZARD INTENSITY LEVEL 86038280 04/04/07 2-2ENG The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words - WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is...
Page 7 - GROUNDING INSTRUCTIONS; GROUNDING INSTRUCTIONS:
GROUNDING INSTRUCTIONS 86038280 04/04/07 2-3ENG THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors. EXTENSION CORD...
Page 8 - TECHNICAL SPECIFICATIONS; ITEM DIMENSION/CAPACITY
TECHNICAL SPECIFICATIONS 86038280 04/04/07 3-1ENG ITEM DIMENSION/CAPACITY Electrical 230-240V, 7A, 50 HZ Electric Vacuum Motor (1) 3 stage, 1 hp, 99 cfm (2.80 cubic m/min.) Waterlift 117” (297cm) Brush (1) 18” (45.7cm.) Brush Speed 1000 rpm Solution Pump 100 PSI, diaphragm style, internal bypass Sol...
Page 9 - CONTROLS/COMPONENT LOCATIONS
CONTROLS/COMPONENT LOCATIONS 86038280 04/04/07 3-2ENG 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle, and allow machine to be used in “PUSH” or “PULL orientation. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bot...
Page 10 - Height
CONTROLS/COMPONENT LOCATIONS 86038280 04/04/07 3-3ENG 1 2 3 13 12 6 9 8 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height ...
Page 12 - OPERATIONS; Adjust brush to proper setting.; CORRECT; INCORRECT
OPERATIONS 86038280 04/04/07 3-5ENG Remove electrical cord and literature from recovery tank. Fill solution tank (see filling instructions). Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage to motor or car...
Page 13 - Lower machine to floor.
OPERATIONS 86038280 04/04/07 3-6ENG Select continuous setting to start solution spray or select intermittent setting to enable use of trigger switches to start solution spray. The intermittent setting requires the operator to hold any one of the three trigger switches in the “on” position with the f...
Page 14 - FILLING OPERATIONS; CHEMICALS; Suitable Chemicals; RECOVERY TANK
FILLING OPERATIONS 86038280 04/04/07 3-7ENG FILLING THE CLIPPER NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank . Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank before...
Page 15 - CLEANING PROCEDURE; OFF; This machine can be operated in either
CLEANING PROCEDURE 86038280 04/04/07 3-8ENG Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before ending cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass. Overlap brush contact area...
Page 16 - OR; shut down the machine; defoamer to recovery tank.
CLEANING PROCEDURE 86038280 04/04/07 3-9ENG STEP 5 STEP 6 After cleaning, turn off all controls, return brush to storage position and carefully unplug machine. STEP 4 STEP 1 Use right side of machine for cleaning against walls. SOLUTION INTAKE COVER VACUUM INTAKE COVER OR Start at wall closest to po...
Page 17 - To speed drying, use a Windblower; SOLUTION
CLEANING PROCEDURE 86038280 04/04/07 3-10ENG To speed drying, use a Windblower ™ fan. Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank. Also drain solution tank after each use. STEP 7 STEP 8 RECOVERY DRAIN SOLUTION DRAIN
Page 18 - ACCESSORY TOOL USAGE
ACCESSORY TOOL USAGE 86038280 04/04/07 3-11ENG Turn on vacuum motor switch and set solution switch to intermittent position. Note: Be sure brush switch is in off position and brush is in storage position. Squeeze handle on accessory tool to begin cleaning. STEP 3 STEP 4 STEP 1 STEP 2 Use only one of...
Page 19 - MAINTENANCE; Turn off all switches and unplug machine.
MAINTENANCE 86038280 04/04/07 4-1ENG ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to ex...
Page 20 - SOLUTION PUMP REPLACEMENT
MAINTENANCE 86038280 04/04/07 4-2ENG SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Remove solution hoses from fittings i...
Page 21 - Inspect and clean filter screen in solution tank.
MAINTENANCE 86038280 04/04/07 4-3ENG PERIODIC MAINTENANCE Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become ...
Page 22 - TROUBLESHOOTING CHART; PROBLEM CAUSE
TROUBLESHOOTING CHART 86038280 04/04/07 4-4ENG PROBLEM CAUSE SOLUTION No Power, Nothing Runs 1. Is the cord plugged in? 2. Circuit breaker tripped in building. 3. Faulty switch. 4. Faulty power cord or pigtail. 1. Plug in cord. 2. Reset breaker 3. Call for service. 4. Call for service. Vacuum Motor ...
Page 23 - NOTES