Page 2 - MOUNTING AND WIRING; CAUTION; REMOVING OLD THERMOSTAT; CONTINUED FROM FIRST PAGE; WARNING; TERMINAL CROSS REFERENCE CHART; D. Mount Thermostat Base: Gently push excess wire back into; Figure 2. Typical wiring for single transformer

Model 350 (Heating and Cooling):A. Remove base from subbase: Loosen the three screws on the base and remove. B. Mount switching subbase: Use the screws provided to mount the subbase to wall (see Fig. 1). C. Attach wires to appropriate terminals: • For two wire systems (Heat Only or Cool Only). If yo...

Page 3 - Typical Zone Valve; Typical Gas Valve; Typical Oil Primary; Figure 5. Anticipator adjustment; Figure 6. Subbase switching and thermostat/system operation

SET HEAT ANTICIPATOR Set anticipator to match the setting of your old thermostat younoted in Step 3, or, the anticipator should be set to match thecurrent rating stamped on your main heating control. The heatanticipator is adjustable from 0.15 to 1.2 amps. Adjust the antici-pator by rotating the con...

Page 4 - TROUBLESHOOTING

Symptom Possible Cause Corrective Action No Heat/No Cool/No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker. (common problems) 2. Furnace power switch to OFF. Turn switch to ON. 3. Furnace blower compartment door or Replace door panel in proper position to engage panel lo...