White Rodgers 1F92-71 - Manuals

White Rodgers 1F92-71 – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8

Summary

Page 2 - SPECIFICATIONS; STAGING DATA; WARNING; Locate thermostat about 5 ft. above the floor.; ROUTE WIRES TO LOCATION; Figure 1. Routing thermostat wires

2 SPECIFICATIONS Anticipation: Heating 4 to 40Cooling 4 to 40Auxiliary 4 to 40 THERMAL DATATemperature Range: 40 ° F to 99 ° F (4 ° C to 37 ° C) STAGING DATA Up to 3 heating stagesUp to 2 cooling stages ACCESSORIES Remote Sense Kit: W. R. Part No. F145-1049 Thermostat Guard: W. R. Part No. F29-0198 ...

Page 3 - REPLACEMENT INSTALLATION; REMOVE OLD THERMOSTAT; Figure 2. Removing thermostat from subbase; TABLE 1. WIRE IDENTIFICATION LABELS; NOTE; TABLE 2. TERMINAL REFERENCE

3 REPLACEMENT INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installa-tion is complete. Verify power is off with a voltmeter. 2. Remove the front cover of the old thermostat. Withwires still attached, remove wall plate from the wall. 3. If the old thermostat ha...

Page 4 - Move subbase out of the way. Drill mounting holes.; Figure 4. Typical wiring diagram for single transformer systems

4 2. Connect wires beneath terminal screws on subbaseusing wiring schematic for your particular application(see figs. 3 through 6). 3. Place subbase over hole in wall and mark mountinghole locations on wall using subbase as a template. 4. Move subbase out of the way. Drill mounting holes. 5. Fasten ...