Page 2 - LIMITED WARRANTY STATEMENT; xi
504 p/n 3039 03 o p M WV -4H V entle ss Ho tpla te Coo k top Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from ...
Page 4 - FEATURES & OPERATING CONTROLS; Fig. 1 Ventilator Section Operating Features & Controls
FEATURES & OPERATING CONTROLS 56 28 19 16 18 23 9 8 a15 a11 53 12 41 44 42 43 40 a6 a31 38 18 16 22 23 VENTILATOR CONTROL PANELsee pages 4 & 5 COOKTOP CONTROL PANELsee pages 4 & 5 WARMER CONTROLSsee pages 4 & 5 a10 70 38 Fig. 1 Ventilator Section Operating Features & Controls 2 5...
Page 5 - If; VENTILATOR SECTION
ITEM a6. 8. 9. a10. a11. 12. a15. 16. 18. 19. 22. 23. 28. a31. 38. 40. 41. 42. 43. 44. 56. 70. DESCRIPTION FIRE SUPPRESSION AGENT TANK (1.5 gal.) ADJUSTABLE (FRONT) LEG RIGID (REAR) CASTER MANUAL PULL STATION FUSIBLE LINKS LOWER REAR ACCESS PANEL DISCHARGE NOZZLE GREASE BAFFLE PRE-FILTER ASSEMBLY HE...
Page 7 - ITEM; ON; COMMENT; SHUT; COOKTOP SECTION CONTROLS
FEATURES & OPERATING CONTROLS (continued) 5 504 p/n 3039 03 o p M W V -4H V entle ss Ho tpla te Coo k top ITEM V1 V2 V3 V4* V5* V6* H1 H2 H3 H4 H5 W.01 W.02 W.03 W.04 W.05 W.06 W.07 W.08 W.09 DESCRIPTION POWER SWITCH POWER ON INDICATOR CHECK FILTERS ALARM INDICATOR REPLACE PREFILTER ALARM INDICA...
Page 8 - Fire suppression system and all associated components must; Authorized Ansul® Distributor ONLY; If a remote pull station is installed, both rear casters (9); PRECAUTIONS AND GENERAL INFORMATION
NOTE: Fire suppression system and all associated components must only be serviced by an authorized Ansul® Distributor. All setup, charging, repair and/or adjustment of the fire suppression system must be performed by an Authorized Ansul® Distributor ONLY . IMPORTANT: If a remote pull station is inst...
Page 9 - AGENCY LISTING INFORMATION; REPLACE PREFILTER; cooktop appliance; PRECAUTIONS AND GENERAL INFORMATION (continued); Warning
AGENCY LISTING INFORMATION STD 4 E146882 OPERATIONAL NOTES: REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is imminent. The actual time between the indicator light coming on and the loss of cooking appliance power will depend upon the cook...
Page 10 - INSTALLATION; DO NOT discard; RISK OF INJURY; UNPACKING & INSPECTION; packed with the appliance before starting any; ANSULEX® Low pH; See; SETUP; for required clearances.
INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. WARNING: RISK OF INJURY Installation procedures must...
Page 11 - SERVICE TECHNICIAN INSTALLATION NOTES; WARRANTY REGISTRATION; ELECTRICAL INSTALLATION; THE; DANGER
SERVICE TECHNICIAN INSTALLATION NOTES An Ansul® technician must charge and arm the fire suppression system before the ventilator blower will operate. See page 10. Installation and start up must be performed by an Authorized Installation Company. Installer must complete the WARRANTY REGISTRATION form...
Page 12 - FIRE SUPPRESSION SYSTEM INSTALLATION; Ansul®; Call your Authorized Ansul® Distributor immediately for; ANSUL®; Recharging
INSTALLATION (continued) FIRE SUPPRESSION SYSTEM INSTALLATION 1. Any REMOTE MANUAL PULL STATION must be installed by an authorized ANSUL® distributor in accordance with the AUTHORITY HAVING JURISDICTION. NOTE: If a REMOTE MANUAL PULL STATION is installed, moving the unit for servicing will cause the...
Page 13 - FILTERS INSTALLATION
FILTERS INSTALLATION 1. FILTER PACK: Ships installed in the hood. If the FILTER PACK is not in position, the CHECK FILTERS indicator will light. If the FILTER PACK becomes clogged, the REPLACE FILTER PACK indicator will glow. To install the FILTER PACK: Position the filter pack with the charcoal por...
Page 14 - WARNING; BURN HAZARD; GREASE TROUGH AND GREASE CUP INSTALLATION; Fig. 8 Roll Warmer Drawer Pan Installation
INSTALLATION (continued) WARNING SLIP / FALL HAZARD SPILLED OIL DO NOT OPERATE UNLESS THE GREASE CUP IS INSTALLED. Oil and moisture will drip onto the floor and falls may result. Death or serious injury may result from slipping and falling CAUTION: BURN HAZARD DO NOT OPERATE UNLESS GREASE TROUGH IS ...
Page 15 - OPERATION; HOT SURFACE; VENTILATOR OPERATION
OPERATION CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. VENTILATOR OPERATION 1. Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position a...
Page 16 - HOTPLATE COOKTOP OPERATION; Control
OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. IMPORTANT: The dial markings are an INDICATION of temperature only. The temperature of the food product depends on many factors, including the size, shape and material of the food container, and ...
Page 17 - Temperature Control
OPERATION (continued) CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. NOTE: The chart below is intended as a guide ONLY. Your own experience with this appliance, type of foods and method of operation will enable you to determine the temperature control and air vent...
Page 18 - RWT- CONTROL MODULE; Release keys when display reads F C.; PROCESS; HOLD; PROCESS; ITEM DESCRIPTION
OPERATION (continued) 16 ºFºCLOAD PROCESS 3 2 5 1 4 RWT- CONTROL MODULE SET SETPOINT TEMPERATURE Press an arrow key: UP arrow to increase DOWN arrow to decrease Release key when desired setpoint temperature is displayed. Reading is locked into memory 3 seconds after last key stroke. Minimum setpoint...
Page 19 - not; HOTPLATE COOKTOP DAILY CLEANING; FREQUENCY; CLEANING INSTRUCTIONS
CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool before cleaning. IMPORTANT: DO NOT spill or pour water into controls, control panel, wiring or coil-type...
Page 20 - VENTILATOR WEEKLY CLEANING
CLEANING INSTRUCTIONS (continued) 18 504 p/n 3039 03 o p M WV -4H V entle ss Ho tpla te Coo k top VENTILATOR WEEKLY CLEANING PREPARATION: Disconnect appliance from electric power Allow to cool before cleaning FREQUENCY: Weekly TOOLS: Warm water and a mild detergent Soft clean cloth or sponge Bristle...
Page 21 - VENTILATOR MONTHLY CLEANING; EXTERIOR
CLEANING INSTRUCTIONS (continued) 19 504 p/n 3039 03 o p M W V -4H V entle ss Ho tpla te Coo k top CAUTION: ELECTRIC SHOCK HAZARD Disconnect appliance from electric power before cleaning. CAUTION: HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. Allow appliance to cool befor...
Page 22 - DRAWER WARMER DAILY CLEANING
CLEANING INSTRUCTIONS (continued) 20 504 p/n 3039 03 o p M WV -4H V entle ss Ho tpla te Coo k top DRAWER WARMER DAILY CLEANING PRECAUTIONS: Turn control knob to OFF. Allow drawers to cool before proceeding. Remove drawer pans and Humitrol racks. FREQUENCY: Minimum -Daily TOOLS: Warm water and mild d...
Page 23 - MAINTENANCE SCHEDULES; STANDARD FOR; Parts used; INSTALLATION, RECHARGE AND MAINTENANCE MANUAL; AUTHORIZED ANSUL® DISTRIBUTOR ONLY)
MAINTENANCE SCHEDULES USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS , N.F.P.A 17A & N.F.P.A. 96 (current editions). DANGER FIRE HAZARD FAILURE TO PROPERLY CLEAN AND MAINTAIN THIS EQUIPMENT CAN CAUSE A FIR...
Page 24 - WELLS
22 504 p/n 3039 03 o p M W V -4H V entle ss Ho tpla te Coo k top WELLS BLOOMFIELD, LLC
Page 26 - ANSUL; SECTION 1 - IDENTITY
24 ANSUL ® ANSUL INCORPORATEDMARINETTE, WI 54143-2542 MATERIAL SAFETY DATA SHEET ANSULEX Low pH QUIC K IDENTIFIER (In Plant Common Name) Manufacturer’sName: EmergencyTelephone No.: ANSUL INCORPORATED CHEMTREC (800) 424-9300 or (703) 527-3887 Prepared By: Address: One Stanton Street, Marinette, WI 54...
Page 28 - TROUBLESHOOTING SUGGESTIONS; CHECK FILTERS; SUGGESTED ACTION; There are no user serviceable components in the appliance.
TROUBLESHOOTING SUGGESTIONS SYMPTOM Ventilator blower won’t run Ventilator blower won’t run — buzzer sounding Ventilator blower runs momentarily, shuts down. CHECK FILTERS light on REPLACE PREFILTER light on. REPLACE FILTER PACK light on SERVICE REQUIRED light on Cooktop won’t heat One or more cookt...
Page 29 - CUSTOMER SERVICE DATA; Wells Bloomfield, LLC
DESCRIPTION SERVICE PART NO. PRE-FILTER 22618 PRE-FILTER CAGE 22683 FILTER PACK (HEPA + CHARCOAL) 22619 GREASE BAFFLE 22684 LEG ASSEMBLY 22646 GREASE CUP 22626 DRIP TRAY, 8” (Spiral Hotplate) 21705 ELEMENT SUPPORT (Spiral Hotplate) 500039 SCRAPER, CLEANING (Ceramic Hotplate) 22445 CLEANING CREME, CE...
Page 30 - Genuine Parts; Wells Bloomfield proudly supports CFESA; WELLS BLOOMFIELD, LLC
Genuine Parts Protect - YOU - All - Ways SERVICE TRAINING - QUALITY SERVICE SERVICE TRAINING - QUALITY SERVICE CUSTOMER SATISFACTION CUSTOMER SATISFACTION Commercial Food Equipment Service Association Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UN...