Page 2 - Caution
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 2 / 30 Copyright © Copyright 2008, Welch Allyn. All rights are reserved. No one is permitted to translate, reproduce or duplicate this manual or any part thereof, in any form, without prior written permission from Welch Allyn. Welch Allyn assumes no resp...
Page 3 - Note; Packing Instructions
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 3 / 30 Warranty, Service, and Spare Parts Warranty All repairs on products under warranty must be performed or approved by Welch Allyn. Unauthorized repairs will void the warranty. In addition, whether or not covered under warranty, any product repair sh...
Page 4 - Limited Warranty Statement
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 4 / 30 Limited Warranty Statement Welch Allyn, Inc. warrants that the Welch Allyn CardioPerfect Workstation computer based product you have purchased meets the labeled specifications of the Product and will be free from defects in materials and workmansh...
Page 5 - Table of contents
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 5 / 30 Table of contents 1. OVERVIEW ........................................................................................................................... 6 2. ABPM 6100 MONITOR .........................................................................
Page 7 - IMPORTANT WARNINGS; Warning
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 7 / 30 IMPORTANT WARNINGS The following warnings apply to the ABPM 6100 Ambulatory Blood Pressure Monitors: Warning DO NOT use the ABPM 6100 monitor in the presence of flammable anaesthetics due to risk of explosion. DO NOT immerse the ABPM 6100 monitor ...
Page 9 - Batteries
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 9 / 30 2.2 Operation This section provides a brief overview of the ABPM 6100 unit, how to load the batteries, and the unit controls. The ABPM 6100 features a simple design. One Start/Stop button functions as the primary control. The LCD (liquid crystal d...
Page 10 - The LCD Display
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 10 / 30 At this point the unit will be ready to upload a BP Study. When the unit is turned on subsequently, the unit will display the following: - Three quick audible beeps. - The number of BP readings (if any) in memory along with a flashing printer sym...
Page 11 - Preliminary Directive
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 11 / 30 3. Interface This section describes how to connect the ABPM 6100 monitor to the patient for monitoring sessions. 3.1 Preliminary Directive Advise the patient to: - Wear a loose fitting blouse or shirt. - Avoid wearing long sleeved sweaters or dre...
Page 12 - Traditional Cuff Placement
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 12 / 30 Arm Circumference Cuff Size Soft disposable cuffs Reusable sleeve cuffs Traditional reusable sleeve cuffs Pediatric Cuff Part 5082-94-3 15.8-21.3 cm NA Part 6100-10 16.0 – 21.8 cm Small Adult Cuff Part 5082-95-3 20.0-27 cm Part 101340 18-27 cm Pa...
Page 14 - Office Readings
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 14 / 30 • Do not remove the cuff between readings 3.6 Office Readings Once the ABPM 6100 monitor has been properly attached to the patient and the PC interface cable has been removed from the unit, it is important and necessary to perform office readings...
Page 15 - Reading Data from the Unit
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 15 / 30 PATIENT DO’S AND DON’TS: Finally, familiarize the patient with the following list of do’s and don’ts: Do: • Wear a loose fitting blouse or shirt. • Record time, symptom/mood and activity/position in the patient diary. • Activate a reading (if the...
Page 17 - Keyspan USB to Serial adapter Install
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 17 / 30 4. Keyspan USB to Serial adapter Install If your computer doesn’t have a COM port you need to install the Keyspan Highspeed USB to serial adapter (USA 19H). The purpose of this section is to assist with the Install of the Keyspan Highspeed USB to...
Page 20 - Maintenance and Cleaning; Maintenance; CLEANING THE ABPM 6100 UNIT
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 20 / 30 5. Maintenance and Cleaning Preventative maintenance should be routinely performed to ensure the safe and efficient operation of the ABPM 6100 monitor. In addition, the monitor should be cleaned after each use. Maintenance The following inspectio...
Page 21 - Calibration Check
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 21 / 30 6. Calibration Check Welch Allyn recommends that the calibration of the ABPM 6100 monitor be verified annually by the user using the following procedure: 1. With the ABPM 6100 unit already powered up, remove one of the AA batteries from the batte...
Page 24 - Automatic Measurement Intervals:
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 24 / 30 Operator Control: • 1-button control and LCD. Automatic Measurement Intervals: • Programmable up to four separate time periods at 5 to 120 minute intervals.
Page 25 - Troubleshooting and Error Codes
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 25 / 30 8. Troubleshooting and Error Codes 8.1 Error Codes The ABPM 6100 monitor displays error codes whenever an error situation is encountered. Error codes will display on the unit’s LCD. Error codes that apply to a specific reading will also display i...
Page 26 - Troubleshooting
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 26 / 30 * Always return ABPM 6100 monitor to an authorized service center for repairs. Unauthorized service will void all warranties. 8.2 Troubleshooting The following table contains a list of troublesome scenarios accompanied by suggestions for problem ...
Page 27 - Guidance and Manufacturer’s Declarations; CAUTION; Electromagnetic Emissions
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 27 / 30 9. Guidance and Manufacturer’s Declarations CAUTION The ABPM6100 needs special precautions regarding EMC and needs to be installed and put into service according to the following EMC information provided. Portable and mobile RF communications equ...
Page 28 - Electromagnetic Immunity
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 28 / 30 Electromagnetic Immunity The ABPM6100 is intended for use in the electromagnetic environment specified below. The customer or the user of the ABPM6100 should assure that it is used in such an environment. Immunity test IEC 60601 test level Compli...
Page 30 - communications equipment and the ABPM6100
ABPM 6100 Hardware Manual DIR 80012720 Ver. B 30 / 30 Recommended separation distances between portable and mobile RF communications equipment and the ABPM6100 The ABPM6100 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the use...