Page 2 - instance; GTW; configurator software must be used.
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 2 FM 4/08 3. Some notables regarding the graphic above. In the steps that follow we are going to focus on four of...
Page 3 - Provide a name for the channel.
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 3 FM 4/08 9. Provide a name for the channel. 10. In this example the device driver selected will be “Modbus Ether...
Page 10 - word order which also represents the default
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 10 FM 4/08 23. The graphic below shows the default Modbus ® word order which also represents the default Modbus ®...
Page 13 - Now that we know the finer details of the Modbus
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 13 FM 4/08 each: PV1 of PM1 = 400361 (offset = 0) PV1 of PM2 = 405361 (offset = 5000) PV1 of PM3 = 410361 (offset...
Page 14 - similar screen as shown below should be displayed.
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 14 FM 4/08 30. To create similar tags for PV2 - PV4 simply click on the duplicate icon (circle) and change the fi...
Page 16 - ST does not support programmable memory blocks. However, any
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 16 FM 4/08 34. To better understand the following discussion and examples download and read the section entitled ...
Page 17 - PM Communications user manual and above as well, the enumerated
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 17 FM 4/08 36. In the screen shot that follows one can see the factory defaults for the Assembly Definition Addre...
Page 19 - PM
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 19 FM 4/08 39. The address shown above represents pointer 12 as shown in the EZ-ZONE ® PM Communications user man...
Page 20 - pointer has indeed been changed to Idle
RUI/Gateway & Modbus ® TCP Configuration & Programming Example Using KEPServerEX 4.0 Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2008 Watlow Electric Mfg Co 20 FM 4/08 42. Lastly, in the screen shot below, notice that the 12 th pointer has indeed been changed to Idle Se...