Page 2 - gen) from the room in which it is installed. Provisions; General Information
2 20002538 The Logsets have been designed and tested to operate safely when installed according to the installation instructions con-tained in this manual. Read all instructions before starting the installation. In the Commonwealth of Massachusetts, all gas fitting and installation of this heater sha...
Page 3 - Installation Requirements; Pressure Test Points; Proposition 65 Warning:; Fireplace; Minimum fireplace dimensions.; High Elevations
3 20002538 Installation Requirements The fireplace must meet the minimum dimensions listed below. (Fig. 1) Do not install the logset if the fireplace does not meet these minimums. Pressure Test Points Copreci Valve: 1/8” N.P.T. plugged tapping is provided on the outlet side of the gas control for a te...
Page 6 - Ventilaton options for confined spaces.; Confined Space
6 20002538 W A R N I N G This heater shall not be installed in a confined space or unusually tight construction unless provisions are made for adequate combustion and ventilation air. W A R N I N G If the area in which the heater may be operated is smaller than that defined as an unconfined space, or i...
Page 7 - Installation Instructions; Fireplace Top View
7 20002538 WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.WARNING: Do not use a blower insert, heat ex-changer insert or other accessory not approved for use with this gas logset.Do not burn solid fuels in a fireplace where an unvented ...
Page 8 - Some of the early units may not have the holes; Locate damper locking bracket.
8 20002538 Damper Stop Installation When installing a decorative gas appliance in a fire-place, some local codes require a damper stop be added so the damper will not close completely. The CFM Corporation damper stop is designed so the damper can be locked in the closed position, and still allow a ve...
Page 9 - DO NOT TEST FOR LEAKS WITH AN OPEN FLAME.; Without Hood
9 20002538 Burner Assembly Location Centrally locate the unit in the fireplace, far enough back into the firebox to accomplish adequate draft (if use as a vented appliance is planned). Ensure the front grate feet sit inside the front edge of the fireplace a minimum of 3 ¹⁄₄ ”. (Fig. 6b) Gas Line Connec...
Page 10 - Clearances; WITHOUT HOOD; Positioning the Logs
10 20002538 Check the inlet pressure to the appliance, to ensure that it is as shown in the table on page 3. The minimum is for the purpose of input adjustment.The pressure is controlled by the regulator and should be checked at the pressure test point located in the control valve body. Access to th...
Page 12 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
12 20002538 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. ...
Page 14 - Typical flame patterns.; Gas Valve Knob; Typical view of pilot burner flame.; LO; Correct SIT valve pilot flame.
14 20002538 LF103�VL21 flames�3/31/99�changed valve 4/14/00 djt HI OFF PILO T LO LF101�VL18 flames�3/29/99�changed valve 4/13/00 djt HI OFF PILO T LO 7” - 9”Approx. 7” - 9”Approx. 6” - 8” Ap- prox. LG101 LG103 LG105 VL24 VL21 VL18 LF105�VL24 flames�4/1/99�changed valve 4/14/00 djt HI OFF PILO T LO 7...
Page 15 - Troubleshooting
15 20002538 Troubleshooting With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free ser- vice. If you do experience a problem, this guide will assist a CERTIFIED SERVICE PERSON in the diag- nosis of problems and the corrective action to be taken. Symptom...
Page 16 - replacement parts
16 20002538 1 a b c d HI OFF PILO T LO 2 3 4 5 6a,b 10a,b 7 8 9 11a,b 12a,b 13a,b 15a,b 2538 VL18,21,24,30 replacement parts 4/4/00 djt 14 16a,b 17 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without ...
Page 18 - Accessories; Accessory; Hood
18 20002538 Model No. Accessories The following accessories are available from your CFM Corporation dealer. Should you need additional information beyond what your dealer can furnish, contact CFM Corporation, 410 Admiral Blvd. Mississauga, Ontario, Canada L5T 2N6, Attention: Technical Service. Acces...
Page 19 - (exclusive of CFM Corporation supplied; B. Cement or ceramic fiber log components:; LIMITED 2/20 YEAR WARRANTY; For Majestic Fireplaces Decorative Gas Appliances
19 20002538 MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSLY INCLUDED. IN NO EVENT SHALL ANY IMPLIED WAR-RANTY PRESCRIBED BY LAW (NOTWITHSTANDING THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EF-FECT AFTER EXPIRATIONS OF THE WARRANTIES SET FORTH IN PARAGRAPHS A AN...
Page 20 - CFM Corporation
© CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com CFM Corporation