Page 2 - Gas Pressure Testing:
2 3311857 WARNING Do not use this appliance or any part that has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. WARNING Young children are not allowed to operate t...
Page 3 - Fireplace Specifications; Your Fireplace Must Include:
3 3311857 Before You Begin -- Attention! A. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and...
Page 4 - Pre-Installation Checklist; All dimensions are minimums.
4 3311857 CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Is the gas supply inlet pressure correct? NG: Min. 5.5” w.c./Max. 14.0” w.c. LP: Min. 11” w.c./Max. 14.0” w.c. Does the firebox meet the minim...
Page 5 - Some of the early fireplace units may not; Gas Plumbed on Left Hand Side of Fireplace; Damper locking bracket; Figure 1; Figure 2
5 3311857 This Damper Stop is designed to work on all CFM Corporation BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6.When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close com-p...
Page 6 - Light a; Damper Stop Installation:; Figure 3; Damper clamp; Figure 4
6 3311857 The Damper Clamp provided keeps your damper from accidentally closing during operation of your set. This Damper Clamp must be installed onto your Damper at all times. NOTE: The damper clamp is designed to hold the damper plate open 3 inches. However, the damper must be fully open when the ...
Page 7 - ASHK; Figure 5; grate clip; Figure 6
7 3311857 Adding Pan Material 1. Open the bag of Vermiculite and spread it evenly across the Burner Pan, to the top, as shown in Figure 5. You may overflow the front and sides of the pan to cover the entire pan and connecting hardware. 2. Next, open the bag of Glowing Embers and place them on top of ...
Page 8 - Leak Test Procedures; Remote Installation; AGa pilot wiring; Figure 8
8 3311857 Leak Test Procedures Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas sup-ply pipe to the burner. Turn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a le...
Page 9 - Place the larger bottom logs onto the grate,; Be sure; Open the bag of lava rock and spread the rocks; Available Log Sets; 8” Standard Round Log Set; 0” Standard Round Log Set; Grate Enhance kit; Figure 9
9 3311857 Optional Fettel Cast Front Grate Attach the fettel to the front of the grate as shown in Figure 9. Log Placement 1. Place the larger bottom logs onto the grate, leaving as much space between them as pos-sible. When burning, the flames should come up directly between the logs. 2. Place the s...
Page 10 - combo log set
10 3311857 LG333 18" Standard split log set 4/04 djt 18” Standard Split Log Set LG333 LG334 24" Standard split log set 4/04 djt 24” Standard Split Log Set LG334 LG335 30" Standard split log set 4/04 djt 30” Standard Split Log Set LG335 LG336 18" Standard combo log set 4/04 djt 18” St...
Page 11 - Lighting the Pilot; What To Do If You Smell Gas; For Your Safety Read Before Lighting
11 3311857 The pilot will resist lighting on new installa-tions due to air in the gas supply line. It may take several minutes to bleed air completely out of the gas plumbing system through the pilot line. This appliance has a pilot which is lit by a spark ignition device (piezo). If the piezo fails...
Page 12 - Troubleshooting; Make sure the damper is wide open at all times.; Match Lighting
12 3311857 Troubleshooting Log Set Is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets (especially propane) to produce moderate levels of carbon (soot) where flame contacts the logs. The logs can be cleaned using a soft-bristle brush. How-ever, if soot is produced whe...
Page 13 - Make sure your gas pressure meets the specifications outlined on
13 3311857 Troubleshooting Pilot Will Not Light Upon initial installation, the pilot may be difficult to light, due to air in the gas line, valve, and pilot tubing. If the pilot does not light for several minutes, try using a match to ignite it for the first few times. Initialing lighting the pilot ma...
Page 14 - parts; b. Bag of Vermiculite
14 3311857 857 ASHKRN/P parts 4/04 djt 1 2 3 4 5 4 6 7a,b 8 10 9 11 13 14 12 18a,b 20 21 19 15 17 16a,b 22 24 23 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. SA18/24/30SHK Series Vented...
Page 15 - Log Set Replacement Parts; Log Sets
15 3311857 SA18/24/30SHK Series Vented Gas Logs - Remote Hearth Kit (Continued) Ref. Description 18” 24” 30” 13. Gas Supply Fitting 3304145 3304145 3304145 14. Flexible Gas Connector 3304176 3304176 3304176 15. Pilot Bracket 4303232 4303232 4303232 16a. Natural Gas Pilot Assembly 20000540 20000540 2...
Page 16 - Log parts
16 3311857 5a 5b 5c 5d 5e 5f 956 Log parts 4/04 1a 1b 1c 1d 1e 1f 1 2a 2b 2c 2d 2e 2f 2g (2) 2 3a 3b 3c 3e 3f 3g 3d 3h 3 4a 4b 4c 4d 4e 4f 4 5 6a 6b 6c 6d 6e (2) 6f (2) 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d 8e 8f 8g 8 9a 9b 9c 9d 9e (2) 9f 9g 9h 9j 9 CFM Corporation reserves the right to make changes in de...
Page 19 - (exclusive of CFM Corporation supplied; B. Cement or ceramic fiber log components:; LIMITED 2/20 YEAR WARRANTY; For VERMONT CASTINGS Decorative Gas Appliances
THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRATIONS OF THE WARRANTIES SET FORTH IN PARAGRAPHS A AND B. A. Gas Appliances, electrical and manual compo-nents, glass panels, all sealants or adhesives and op-tional accessories (exclusive of CFM Corporation supplied decorative logs which ...