Page 2 - TABLE OF CONTENTS; Replacement Parts List
- 2 - TABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Majestic fireplace IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions ...
Page 3 - LOCATING YOUR MAJESTIC; INSTALLATION INSTRUCTIONS
- 3 - This gas fireplace should be installed by a qualified installer inaccordance with local building codes and with current CAN /CGA-B149 (. 1 or .2) Installation codes for Gas BurningFireplaces and Equipment. FOR U.S.A Installations follow local codes and/or the currentNational Fuel Gas Code. ANS...
Page 4 - FIREPLACE DIMENSIONS
- 4 - A C B D E F K G H I J A B C D E F G H J I K A B C N K D M J I H L FIREPLACE DIMENSIONS MODEL RFS22 MODEL RFS32 A 25" 635mm B 24 1/8" 613mm C 16" 406mm D 20" 508mm E 19" 483mm F 21" 533mm G 31 3/4" 806mm H 17 3/4" 451mm I 29 5/8" 752mm J 9" 229mm K 5 1/4&...
Page 5 - GAS INLET & MANIFOLD PRESSURES; Input Minimum; GAS LINE INSTALLATION; PREPARATION; GAS SPECIFICATIONS; Vented Gas Fireplace Heaters
- 5 - GAS INLET & MANIFOLD PRESSURES Input Minimum Input Maximum Manifold Pressure NATURAL LP (Propane) 11" wc 13" wc 10" wc 4.5" wc 7" wc 3.5" wc 1/2" GAS SUPPLY 1/2" X 3/8" REDUCER 3/8" NIPPLE 3/8" NIPPLE 3/8" NIPPLE 3/8" X 3/8" SHUT OFF ...
Page 6 - OPTIONAL FAN KIT - FK24; STANDARD WITH RFS42; . The gas inlet hole has a plastic cap in it.
- 6 - INSTALLATION OF REMOTE SWITCH FOR RN/RP GAS VALVE Install on/off switch assembly on either the rear right orleft side of the RFS22/RFS32/RFS42 Gas Fireplace.1. Remove the screw at the back of the cabinet top eitheron the left or the right side of the fireplace. 2. Position switch assembly onto...
Page 8 - Retrofitting To An Existing Brick Chimney; PROPER VENT PERFORMANCE; VENT SAFETY SYSTEM
- 8 - Check Draft Here Fig. 12 Retrofitting To An Existing Brick Chimney The CFM Majestic Products Company strongly recommendsinstalling an approved chimney liner in an existing brickchimney. This will maximize the potential draft of the chimney andlessen the effects of slow chimney start up. This i...
Page 9 - GENERAL GLASS INFORMATION; OPERATING INSTRUCTIONS; LOUVRE REMOVAL
- 9 - GENERAL GLASS INFORMATION Only glass approved for use in The CFMMajestic Products Company productsmay be used for replacement. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. Under no circumstances should this fireplacebe o...
Page 10 - GLASS CLEANING; MAINTENANCE
- 10 - KR2 KR5 KR6 KR4 KR3 KR1 Burner Lava Rock Placement ,, ,, ,, Fig. 16 GLASS CLEANING It will be necessary to clean the glass periodically.During start-up condensation, which is normal, forms onthe inside of the glass and causes lint, dust and otherairborne particles to cling to the glass surfac...
Page 11 - CLEANING PROCEDURE; CERAMIC REFRACTORY; TEMPERATURE ADJUSTMENT; FLAME CHARACTERISTICS
- 11 - CLEANING PROCEDURE 1. Turn off pilot light at gas valve. 2. Remove front glass. 3. Remove logs. CAUTION: LOGS MAY BE HOT 4. Vacuum burner compartment especially around orifice/primary air openings. 5. Reinstall logs. 6. Check pilot and main burner operation. 7. Reinstall front glass. 8. Reche...
Page 12 - FOR YOUR SAFETY READ BEFORE LIGHTING; TO TURN OFF GAS TO FIREPLACE; LIGHTING AND OPERATING INSTRUCTIONS; LIGHTING INSTRUCTIONS; EURO SIT
- 12 - 4. Push in gas control knob slightlyand turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressingthe piezo spark ignitor until a flame appears.Continue to hold the contr...
Page 13 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM
- 13 - SIT 630 GAS VALVE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective...
Page 14 - SIT NOVA 820 MILLIVOLT VALVE
- 14 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT NOVA 820 MILLIVOLT VALVE Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ...
Page 15 - START; CHECK; HONEYWELL MILLIVOLT VALVE
- 15 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED.• ALL WIRING CONNECTIONS• REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES• THERMOPILE N...
Page 16 - REPLACEMENT PARTS LIST; ESCRIPTION
- 16 - REPLACEMENT PARTS LIST D ESCRIPTION RFS22 RFS32 RFS42 (1) Top or Bottom With Magnets 1. Log Set Complete 10000160 10000160 10000205 1a. Log Ember Front KR1 KR1 SR1 1b. Log Front Left KR2 KR2 SR2 1c. Log Front Right KR3 KR3 SR3 1d. Log Rear KR4 KR4 SR4 1e. Log Top Left KR5 KR5 SR5 1f. Log Top ...
Page 17 - REPLACEMENT PARTS
- 17 - REPLACEMENT PARTS 29 30 27 5/6a/b 19 18 13 11 17 15 28 7a/b 21a,b 44 41 42 43 31 32 36 a/b 37 39 46 45 39 43 41 42 it HI LO OFF PILOT 25a/b 48 47 40 14 33 38 42 39 34 35 39 43 33 49 26 #1 - COMPLETE LOG SET -- RFS22/RFS32 1b 1d 1e 1f 1a 1c 22 23 3a/b 4 2 40 8 a/b 12 17 16 LO HI PILOT ADJ PILO...
Page 18 - REMOTE CONTROL; OPTION
- 18 - MRC1 - On/Off Button Remote Control MRC2 - Temperature Control Remote MRC3 - Temperature Control w/digital display & 24 hour programmable clock I M T - Wall Mounted Thermostat REMOTE CONTROL For units with RN/RP valves OPTION S