Page 2 - WARNING; Proposition 65 Warning:
2 20007967 Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam-age. Read these directions thoroughly before installation. For assistance or additional information, consult your gas log dealer, qualified installer, service agency or gas supplier. Youn...
Page 3 - General Information
20007967 3 The Logsets have been designed and tested to oper-ate safely when installed according to the installation instructions contained in this manual. Read all instruc-tions before starting the installation. • For outdoor use only.• The logset should be inspected before use and at least annuall...
Page 5 - Gas Plumbed on Left Hand Side of Fireplace; R-CFL Gas Supply Connection; LP hook up; alternate left
20007967 5 NOTE: Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas on the right side (facing). If your fireplace is plumbed with the gas on the left side remove fittings on right and left side of straight burner tube and switch sides, at the same time put ...
Page 6 - Leak Test Procedures; NEVER test; Light a tightly; Damper Stop Installation
6 20007967 Leak Test Procedures After connecting the gas supply, test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fitting and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame. WARNING: DO NOT USE AN OPEN FLAME TO...
Page 7 - ” back from; Add Pan Material; grate placement; OD24 lava rock; ember placement; screen placement; lava rock placement
20007967 7 Grate Placement Grate Assembly Place grate assembly over top of burner so the front middle leg of the grate is 1 ¹⁄₂ ” back from the front edge of the main burner pan assembly. (Fig. 7) Add Pan Material 1. With burner pan and grate in place, open the bag of lava rock and spread it evenly ...
Page 8 - Log Placement; log placement; Optional Glass Door Set; Unit
8 20007967 1. Place the larger bottom logs (longer log in back, shorter (2) logs in front) onto the grate, leaving as much space between them as possible. (Fig. 12) Log Placement 2. Next, place the smaller top logs diagonally onto the bottom logs, so that the logs are in notches provided. (Fig. 13) ...
Page 9 - To Turn the Appliance Off:; Rotate the gas shut-off valve clockwise; To ensure proper curing of the logs:; Lighting Instructions
20007967 9 What To Do If You Smell Gas • Do not try to light any appliance.• Do not touch any electrical switch, do not use any phone in the immediate area.• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.• If you cannot reach your gas supplier, ca...
Page 10 - Troubleshooting; Log Set Is Smoking/Sooting Excessively; Burner Is Excessively Noisy; Excessive gas pressure:
10 20007967 Troubleshooting Log Set Is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flame contacts the logs. The logs can be cleaned using a soft-bristle brush. However, if soot is pro-duced where there is no flame ...
Page 11 - OD24SHK Vented Gas Logs
20007967 11 1 2 3 4 7 6 8 9 7967 OD24SHK PARTS 5/04 10 11 14 15 12 13 16 17 1a 1b 1c 1d 1e 5 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 7967 OD24SHK Vented Gas Logs Ref. D...
Page 12 - (exclusive of CFM Specialty Home; B. Cement or ceramic fiber log components:; LIMITED 2/20 YEAR WARRANTY; For VERMONT CASTINGS Decorative Gas Appliances
ARE HEREBY EXPRESSLY INCLUDED. IN NO EVENT SHALL ANY IMPLIED WARRANTY PRESCRIBED BY LAW (NOTWITHSTANDING THE FOREGOING EXPRESS EX-CLUSION) REMAIN IN EFFECT AFTER EXPIRATIONS OF THE WARRANTIES SET FORTH IN PARAGRAPHS A AND B. A. Gas Appliances, electrical and manual compo-nents, glass panels, all sea...