Page 2 - ODSHR Outdoor Woodburning Fireplace; PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.; Table of Contents
2 ODSHR Outdoor Woodburning Fireplace 20002264 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Saf...
Page 3 - ODSHR Outdoor Woodburning Fireplace; Safety Information; Description; Any such action may possibly cause a fire hazard.; before; installing the fireplace.; Drafts; Proposition 65 Warning:; Fuels used in gas, woodburning; Listed; Standard for Factory Built Fireplaces
3 ODSHR Outdoor Woodburning Fireplace 20002264 Safety Information Description The ODSHR Series (Super Hearth) fireplace is a clean-faced, solid fuel, woodburning fireplace. Precautions CFM Corporation fireplaces and component parts have been highly tested and will operate safely when installed in accor...
Page 4 - ODSHR42 Series specifications and framing.; ODSHR42 Series Woodburning Fireplace; hearth dimensions; Front Width; Exterior chase installation.; When installation
4 ODSHR Outdoor Woodburning Fireplace 20002264 Minimum Rough Opening Height 42" (1067 mm) 52 ��� " (1327 mm) 44" (1118 mm) ��� " ��� " �� " (610 mm) ����� " (189 mm) 13 ��� " Dia. Minimum Rough Opening Width 53 ��� " (1365 mm) Minimum Rough Opening Depth 62 ��� ...
Page 5 - Chase Installation; Fireplace and chase parts identification.; fireplace setting; If the fireplace is a free-; Freestanding installation.; Exterior Chase Installation
5 ODSHR Outdoor Woodburning Fireplace 20002264 FP554A SH Series 1/28/99 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation or exterior installation . FP554A Fig. 4 Fireplace and chase parts identification. Termination CapStorm CollarPan...
Page 6 - Chimney Requirements - Offset Installations; 0 ̊ Elbow Offsets; Illustration Key; total; MBUF; OFFSET; RISE
6 ODSHR Outdoor Woodburning Fireplace 20002264 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 11" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 11 ¹⁄₄ " 25 ¹⁄₄ " 2 0 0 0 0 13 ¹⁄₂ " 29 ¹⁄₄ " 1 1 0 0 0 16 ¹⁄₂ " 34 ¹⁄₄ " 0 0 1 0 0 20 ¹⁄₄ " 40 ³⁄₄ " 2 1 0 0 0 ...
Page 7 - Planning Information; The Ten Foot Rule; must; Planning the Chimney Run; Never; Installed lengths of chimney sections.; Ten Foot Rule illustration.
7 ODSHR Outdoor Woodburning Fireplace 20002264 Planning Information The Ten Foot Rule Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed...
Page 8 - Chimney Supports; must not; highly recommended; Installation; Chimney support installation; Insulating between platform and fireplace.
8 ODSHR Outdoor Woodburning Fireplace 20002264 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with 11CF chimneys. Locate chimney supports at cei...
Page 9 - Ceiling Chimney Hole/ Possible Obstructions; Framing; only; Straight-Up Chimney Installation; Elbow; Locate centerline of chimney with plumb line.
9 ODSHR Outdoor Woodburning Fireplace 20002264 Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used. Mea-sure your offset dimension from straight up chimney center point on ceiling. Ceiling Chimney Hole/ Possible Obstructions The size of the hole in...
Page 10 - Cutting the Hole; Angle of Chimney at Ceiling; The; inside dimension; of the frame; must be; the same
10 ODSHR Outdoor Woodburning Fireplace 20002264 Cutting the Hole Cover fireplace collar opening and cut proper sized chimney hole in chimney. Framing the Ceiling Hole Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling j...
Page 11 - Securing the Fireplace; Safety strips are not required over noncombus-; Installing Outside Air Kit; MUST; be installed; BEFORE; Fasten fireplace in position.; Safety strip installation.; Outside air operation.
11 ODSHR Outdoor Woodburning Fireplace 20002264 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position.Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 ¹⁄₂ " (38 mm), allowing the remainder to extend in front of firebox. O...
Page 12 - Installing the Chimney System; Make sure the; Installing the Firestop Spacer; A firestop spacer; Proper Firestop Spacer Installation; is; is not; Elbow Strap; Attach straps to a structural framing member.; Attic Installation; Installing firestop spacer.; snap lock
12 ODSHR Outdoor Woodburning Fireplace 20002264 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 17. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-lo...
Page 13 - Ten Foot Rule
13 ODSHR Outdoor Woodburning Fireplace 20002264 Firestop spacers are not available for, nor are they required on, vertical walls.The CFM Corporation chimney components have been tested and approved with the area where the outer pipe slides through the firestop spacer sealed with a noncombustible caul...
Page 14 - Finish Wall; Finish the wall with material of your choice.; Do not; No side wall protection is required for fireplaces; Minimum clearances to combustibles.; SHR air spaces; Air Space Clearances; Front View; Must; Fireplace surround flush with finished wall.; Side View; Facing on fireplace surround flush with finished wall.
14 ODSHR Outdoor Woodburning Fireplace 20002264 Finish Wall Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305 mm) from the top of the fireplace opening. Do not install a mantel face plate less than 6" (154 mm) from top of fireplace openi...
Page 15 - Combustible mantel clearances.
15 ODSHR Outdoor Woodburning Fireplace 20002264 FP531surround flush withfinish wall12/20/01 djt 12" (305mm) Max. 12" (305mm) min. * 1 ¹⁄₂ " 12" (305mm) Max. 12" (305mm) min. 1 ¹⁄₂ " 6" (159mm) Min. 1" Mantel Clearance - No Noncombustible Facing Material Combustible Ma...
Page 16 - Side Wall Protection; Examples of wall shield insulation:; Hearth Installation; Noncombustible wall shield dimensions.; Minimum Wall Clearances; or
16 ODSHR Outdoor Woodburning Fireplace 20002264 Side Wall Protection Adjacent combustible side walls that are within dimen-sions shown in Figure 25 of fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 26.The special ...
Page 17 - COMMON MATERIALS AND FACTORS; Common Brick; To determine the thickness required for any; new
17 ODSHR Outdoor Woodburning Fireplace 20002264 COMMON MATERIALS AND FACTORS MATERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (CFM Corporation) R Value is for ��� inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/...
Page 18 - Installing Line for Gas Logs; CSA draft; If installing an unvented gas log set, refer to statement below:; SHR series
18 ODSHR Outdoor Woodburning Fireplace 20002264 Installing Line for Gas Logs CFM Corporation fireplaces are designed to accept a 1/2 inch gas line for installation of an approved gas ap-pliance. (CFM Corporation manufactures a wide variety of gas logs for use in Majestic Fireplaces units.)Be sure to ...
Page 19 - odshr; Part Number; Firebrick Retainers
19 ODSHR Outdoor Woodburning Fireplace 20002264 * Two (2) required ** Four (4) required CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 2264pts odshr replacement parts 1/5/00 djt 1 2 5 7 6...
Page 20 - Accessories
20 ODSHR Outdoor Woodburning Fireplace 20002264 The following accessories for this appliance are available from your local CFM Corporation products distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd., Mississau...
Page 21 - Accessory
21 ODSHR Outdoor Woodburning Fireplace 20002264 Accessory Description Model No. Extended Round Top Chimney Sections Chimney Elbows Top HousingwithUpper Baffle Chimney Reducer Kit Attic Insulation Shield For use with Type "11CF" Chimney Sys-tems. Used to terminate chimney at top of chase. Adap...
Page 23 - LIMITED WARRANTY & 30 YEAR PROTECTION PLAN; For Majestic Fireplaces PRE-ENGINEERED Fireplace Systems; CFM Corporation
23 ODSHR Outdoor Woodburning Fireplace 20002264 LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For Majestic Fireplaces PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its Pre-Engineered Fireplace (“Fireplace”) and the CFM Corporation-supplied firegrate, glass doors, outside air system, fan ...