Page 2 - Vermont Castings, Majestic Products: DVR33; Table of Contents; Installation and Operating Instructions
2 Vermont Castings, Majestic Products: DVR33 10004920 Table of Contents Thank You and Congratulations on Your Purchase of a Vermont Castings, Majestic Products Fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may re...
Page 3 - IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY; Locating Your Fireplace; Fig. 1 Locating Your Gas Fireplace
3 Vermont Castings, Majestic Products: DVR33 10004920 This gas appliance should be installed by a qualified installerin accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances andEquipment. If the unit is being installed in a mobile home, theins...
Page 4 - Appliance Dimensions; Framing Dimensions; Fig. 2 Fireplace specifications and framing dimensions.
4 Vermont Castings, Majestic Products: DVR33 10004920 Appliance Dimensions Fireplace Dimensions A 33” 838 mm B 28 7 / 8 ” 733 mm C 16 3 / 8 ” 416 mm D 31” 787 mm E 22 1 / 16 ” 560 mm F 11 1 / 2 ” 292 mm G 14 3 / 4 ” 375 mm H 24 1 / 2 ” 622 mm I 5” 127 mm J 7 1 / 2 ” 127 mm K 8 1 / 2 ” 216 mm R 31” 7...
Page 5 - Mantels; Appliance; Hearth; Fig. 4a Combustible mantel leg minimum installation; Mantel Height above; Fig. 4b Mantel leg dimensions
5 Vermont Castings, Majestic Products: DVR33 10004920 Mantels The height that a combustible mantel is fitted abovethe fireplace is dependent on the depth of the mantel.This also applies to the distance between the mantelleg (if so fitted) and the fireplace. Refer to Fig. 4a andFig. 4b, and the Mante...
Page 6 - Adjustable Drywall Strip; Screw; Final Finishing
6 Vermont Castings, Majestic Products: DVR33 10004920 Fig. 5 Adjustable drywall strip (nailing flanges). C A B Adjustable Drywall Strip (Nailing Flange) Screw Drywall Position Depths A 1/2” (13 mm) B 5/8” (16 mm) C 3/4” (19 mm) FP1023 Adjustable 1/2”, 5/8” & 3/4” Spacing Noncombustible materials...
Page 7 - Gas Line Installation; Thread the wiring through the electrical knockout; Remote ON/OFF Switch Installation; Fig. 7 Remote switch wiring diagram for RN or RP models.; Alternate Switch Location
7 Vermont Castings, Majestic Products: DVR33 10004920 The gas pipeline can be brought in through the side ofthe fireplace as well as the bottom. Knockouts areprovided on the bottom behind the valve to allow for thegas pipe installation and testing of any gas connection.It is most convenient to bring...
Page 8 - Outside; Inside
8 Vermont Castings, Majestic Products: DVR33 10004920 FP580 Fig. 9 EB-1 receptacle. 5. Connect black wire of the power supply line to the brass screw (polarized) of the socket assembly. 6. Connect the white wire of the power line to the chrome screw of the socket assembly. 7. Connect the ground wire...
Page 9 - Electronic Gas Control Valve; General Venting Information; Location of Vent Termination
9 Vermont Castings, Majestic Products: DVR33 10004920 Fig. 10 Honeywell Ignition Module. This appliance may be fitted with a HoneywellIgnition Module. To install the remote On/ Off starter switch onelectronic ignition units (Fig. 10): 1. Thread the wiring through the holes on the sidepanels of the a...
Page 10 - Canadian Installations; General Venting Information–Termination Location; Fig. 11 Vent termination clearances
10 Vermont Castings, Majestic Products: DVR33 10004920 Canadian Installations 1 US Installations 2 A = Clearance above grade, veranda, porch, 12 in. (30 cm) 12 in. (30 cm) deck or balcony B = Clearance to window/door that may be opened 6 in. (15 cm) for appliances <10,000 Btuh 6 in. (15 cm) for a...
Page 11 - General Information for Connecting Vent Pipes; Crimped End Pipes; Canadian Installations:; Fig. 13 Apply a bead of high temperature sealant.; Outside Corner; Termination Clearances; Recessed Location
11 Vermont Castings, Majestic Products: DVR33 10004920 General Information for Connecting Vent Pipes Crimped End Pipes Before joining elbows and pipes, apply a bead of hightemperature sealant to the crimped end of the elbow orpipe. Join the pipes using a 2” (50 mm) overlap and securethe joints with ...
Page 12 - Rear Wall Vent Installation; Combustible Walls: Cut a 10; Twist Lock Pipes; Rear Wall Vent Application
12 Vermont Castings, Majestic Products: DVR33 10004920 Max. 20"(508 mm) Top view flat installation Max. 20"(508 mm) Top view corner installation FP1188 Fig. 15 Rear vent application, maximum horizontal distance. Rear Wall Vent Installation Step 1 Locate and cut the vent opening in the wall. ...
Page 14 - Vertical Sidewall Application; transition elbow; elbows per installation.; How To Use the Vent Graph; Vertical Dimension From The Floor Of the unit
14 Vermont Castings, Majestic Products: DVR33 10004920 Since it is very important that the venting systemmaintain its balance between the combustion airintake and the flue gas exhaust, certain limitationsas to vent configurations apply and must be strictlyadhered to. The Vent Graph, showing the rela...
Page 15 - Fig. 21 Maximum horizontal run with no rise.
15 Vermont Castings, Majestic Products: DVR33 10004920 “A” 10’ (3048 mm) 7’6” (2286 mm) 90 ° Elbow = 3’ V584-201 A + B = 17’ (5.2 m) max. Fig. 22 Maximum vent run with elbows. As shown in Fig. 22, the total of dimension A and B isnot to be greater than 17’ (5.2 m). • The maximum number of 45˚ elbows...
Page 16 - Vertical Sidewall Installation; Fig. 25 Adjustable zero clearance sleeve.; NOTE: Sealing vent pipe and firestop gaps with; 40 mm) hole through the exterior wall and frame.; Noncombustible Walls: Hole opening must be 7
16 Vermont Castings, Majestic Products: DVR33 10004920 Vertical Sidewall Installation #8 Screws (2) #8 Screws (2) 12" (304.8 mm) max. Firestop (Side View) CFM135a Fig. 25 Adjustable zero clearance sleeve. Zero clearance sleeve is required onlyfor combustible walls. Fig. 26 Vertical height requir...
Page 17 - Below Grade Installation; NOTE: Ensure that sidewall venting clearances
17 Vermont Castings, Majestic Products: DVR33 10004920 Fig. 27 Horizontal length requirement. Below Grade Installation CFM193 Fig. 28 Below grade installation. Do not backfill around snorkel.A clearance of at least 4” (102 mm) mustbe maintained between the snorkel andthe soil. Step 7 Apply high temp...
Page 18 - Fig. 30 Support straps for horizontal runs.
18 Vermont Castings, Majestic Products: DVR33 10004920 WatertightSeal Around Pipe Foundation Recess Sheetmetal screws Wall screws Snorkel CFM139 Fig. 29 Snorkel installation, recessed foundation. This Gas Fireplace has been approved for, • Vertical installations up to 40’ (12 m) in height. Up toa 10...
Page 19 - Upper Floor; Fig. 32 Attic insulation shield and firestop spacer.
19 Vermont Castings, Majestic Products: DVR33 10004920 11" 11" Attic InsulationShield Upper Floor CeilingInstallation Joist Nails (4) FirestopSpacer FP1029 Fig. 32 Attic insulation shield and firestop spacer. TypicalRoofSupportApplication Typical CeilingSupportApplication FP1184 Fig. 32 Vent...
Page 20 - DVR33 Bracket Restricter Installation; Fig. 35 Baffle firebox assembly; NOTES: When installing DVR33 with a vertical; Fitting the Bracket Restricter; Refit the baffle assembly to the firebox,; Fig. 36 Top face of baffle assembly; Baffle firebox assembly
20 Vermont Castings, Majestic Products: DVR33 10004920 DVR33 Bracket Restricter Installation Fig. 35 Baffle firebox assembly NOTES: When installing DVR33 with a vertical through-the-roof configured flue system,the bracket restricter supplied with theappliance (part# 10002910) should befitted to the ...
Page 21 - Twist Lock Venting Components
21 Vermont Castings, Majestic Products: DVR33 10004920 Twist Lock Venting Components 7DVRVT - Through-the-Wall Rear Vent Termination Starter Kit-Model 7TDVSK - Sidewall VentingStarter Kit-Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitchfor 7TDVSKV-B order 7/12 to 12/12 ro...
Page 22 - Crimped End Venting Components
22 Vermont Castings, Majestic Products: DVR33 10004920 7DVRVT - Through the wall Rear Vent Termination Starter Kit-Model 7DVSK - Sidewall VentingStarter Kit-Model 7TDVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitchfor 7DVSKV-B order 7/12 to 12/12 roof pitchfor 7DSKV-F order flat ro...
Page 23 - Operating Instructions; Glass Information; NOTE: The louvre assembly bottom is hinged at; Glass Cleaning; Window Frame Assembly Removal
23 Vermont Castings, Majestic Products: DVR33 10004920 Operating Instructions Use only glass approved by VermontCastings, Majestic Products on thisfireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Under...
Page 24 - Flame and Temperature Adjustment; Fig. 41 Flame adjustment knob for Honeywell Valve.; Honeywell Valve; Installation of Logs; NOTE: Glowing lava rock for DVR33 is only
24 Vermont Castings, Majestic Products: DVR33 10004920 RN/RP and EN/EP Models For units equipped with ‘HI/LO’ valves the flameadjustment is accomplished by rotating the ‘HI/LO’adjustments knob located near the center of the gascontrol valve (Fig. 41 and Fig. 42). Flame and Temperature Adjustment Fig...
Page 25 - Fig. 43 Correct pilot flame appearance.; Fig. 44 Correct burner flame appearance.
25 Vermont Castings, Majestic Products: DVR33 10004920 This appliance venting system is designed andconstructed to develop a positive flow adequate toremove flow gases to the outside atmosphere. Any foreign objects in the venting system, except thosedesigned specifically for the venting system, mayc...
Page 26 - FOR YOUR SAFETY, READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
26 Vermont Castings, Majestic Products: DVR33 10004920 3. Open louvre assembly bottom.4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.2. Turn off all electrical power to the fireplace.3....
Page 27 - Do not try to light any appliance; For your safety, read the following warnings
27 Vermont Castings, Majestic Products: DVR33 10004920 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try tolight the pilot by hand. B. BEFORE OPERATING, s...
Page 28 - Troubleshooting – Honeywell Millivolt Valve
28 Vermont Castings, Majestic Products: DVR33 10004920 Troubleshooting – Honeywell Millivolt Valve START CHECK Gas Supply ON ▼ ▼ ▼ ▼ ▼ Pilot lights with Piezoigniter • Lockout has engaged. Wait 60seconds and try again. • For spark at electrode whiledepressing Piezo, 1/8" gapto pilot hood needed....
Page 29 - SYMPTOM; Troubleshooting the Gas Control System; SIT NOVA 820 MILLIVOLT VALVE
29 Vermont Castings, Majestic Products: DVR33 10004920 WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot...
Page 30 - SIT 822 Valve with a Honeywell Electronic Igniter; START
30 Vermont Castings, Majestic Products: DVR33 10004920 SIT 822 Valve with a Honeywell Electronic Igniter NOTE: Remove glass before servicing. START TURN GAS SUPPLY OFF TURN ON/OFF SWITCH TO CALL FOR HEAT POWER TO MODULE (24V NORMAL) APRK ACROSS IGNITOR SENSOR GAP YES YES YES TURN GAS ON PILOT BURNER...
Page 31 - Fuel Conversion Instructions; Nova SIT820 Gas Valve; Fig. 47 Nova SIT 820 gas valve conversion.; For RN and RP models only:
31 Vermont Castings, Majestic Products: DVR33 10004920 Fuel Conversion Instructions Honeywell Gas Control Valve (Fig. 48):The Honeywell valve fitted to this unit is suitablefor use with LP or Natural Gas. It is converted tothe required gas application by installation of acolor coded “conversion scre...
Page 32 - Maintenance; Burner and Burner Compartment; General Maintenance
32 Vermont Castings, Majestic Products: DVR33 10004920 Regulator Cap Conversion Screw PressureRegulatorHousing Honeywell Gas Valve CO123 Fig. 48 Honeywell gas valve conversion. Maintenance Burner and Burner Compartment It is important to keep the burner and the burnercompartment clean. At least once...
Page 34 - Description; Lava Rock 1 lb. package
34 Vermont Castings, Majestic Products: DVR33 10004920 40 41 42 39 19 30 29 28 27 25 24 Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors andproducts at any time, without notice. DVR33 (Items marked with ‘*’ are...
Page 37 - Optional Accessories; Method A; Fan; Fan Kits
37 Vermont Castings, Majestic Products: DVR33 10004920 Optional Accessories FK-24 Fan Assembly Fan specifications: 120 volt, 60 Hz, 0.75 Amp. This fan does not need regular maintenance, howeverperiodic cleaning is required. Check the area under thecontrol door and in front of the fan and wipe or vac...
Page 38 - Fig. 52 Install ceramic refractory panels.; Decorative Bay Windows; Fig. 53 Place the rear panel on rear support brackets.
38 Vermont Castings, Majestic Products: DVR33 10004920 Do not remove the existing windowframe assembly. Side panel Floor refractory panel Log Support Lower side support Adjustable tab Lower side support Adjustable tab Side panel BURNER HOUSING ASSEMBLY Back Panel FP1193 Fig. 52 Install ceramic refra...
Page 40 - IF WARRANTY SERVICE IS NEEDED...; ) DO NOT ATTEMPT TO DO ANY SERVICE WORK; LIMITED LIFETIME WARRANTY
BASIC WARRANTY The Vermont Castings , Majestic Products Company (hereinafter referred to collectively as the Company) warrants that your newVermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from thedate of purchase, subject to t...