Page 2 - CR Series Woodburning Fireplaces; Safety Information; Description; installing the fireplace.; Table of Contents; Listed; framing the fireplace. The gas line must
2 CR Series Woodburning Fireplaces 20001316 Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void th...
Page 3 - CR Specs; CR36R/L Series Woodburning Fireplace; CR Hearth size
3 CR Series Woodburning Fireplaces 20001316 325 CR Specs 3/3/99 djt Rough Opening Depth 22 ³⁄₄ " (578mm) 22" (559mm) 10" (254mm) ³⁄₄ " (19mm) ⁷⁄₁₆ " (11mm) 29 ¹⁄₄ " (743mm) 11 " Dia. (279mm) 1" Typ. (25mm) 9 ⁷⁄₈ " (251mm) 6" (159mm) 19 ⁹⁄₁₆ " (497mm) 21 ⁷⁄...
Page 4 - Chase Installation
4 CR Series Woodburning Fireplaces 20001316 FP704CR CR chase install 4/26/99 djt from FP704 STR Termination Cap Storm Collar Pan Flashing Draftstop Finish Wall Surround Screen Grate Firebox Outside Air Control Outside Air Cover Plate Gas Access See Figure 20 on page 15 for clearance information Oute...
Page 5 - CR Series; 0 ̊ Elbow Offsets; Illustration Key; Chimney Requirements - Offset Installations; MBUF
5 CR Series Woodburning Fireplaces 20001316 0 0 0 0 0 3” 11” 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 11 ¹⁄₄ " 25 ¹⁄₄ " 2 0 0 0 0 13 ¹⁄₂ " 29 ¹⁄₄ " 1 1 0 0 0 16 ¹⁄₂ " 34 ¹⁄₄ " 0 0 1 0 0 20 ¹⁄₄ " 40 ³⁄₄ " 2 1 0 0 0 21 ³⁄₄ " 43 ¹⁄₂ " 0 0 0 1 0 26 ¹⁄₄ " 51 ¹⁄₄...
Page 6 - Planning Information; Mounting the Fireplace; must; Planning the Chimney Run; Never; The Ten Foot Rule; must not
6 CR Series Woodburning Fireplaces 20001316 Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only b...
Page 7 - Insulating Fireplace Enclosure For; If you live in a cold climate, it is not required but; highly recommended; that you insulate fire-; very important; for outside wall; before; fireplace is; DO NOT; caulk; Installation
7 CR Series Woodburning Fireplaces 20001316 Angled chimney runs require a support every 6’ (1.8m) in addition to the elbow straps. Chimney supports are used for this function. (Fig. 6) Chase Installation A chase is a vertical box-like structure which encloses the fireplace and/or chimney. Chases are ...
Page 8 - Framing; Framing should be positioned to accommo-; Straight-Up Chimney Installation; Insulation; Offset Installation; Elbow
8 CR Series Woodburning Fireplaces 20001316 Framing Framing can be constructed before or after the fire-place is set in place, however, most installers build the frame before setting the fireplace.Frame fireplace with 2 x 4 lumber or heavier materi-als. Refer to framing dimensions in Figures 1 or 2 for...
Page 9 - MUST; Safety strip installation
9 CR Series Woodburning Fireplaces 20001316 Ceiling Chimney Hole/ Possible Obstructions The size of the hole in the ceiling will vary with the angle at which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney center point. Go to floor above and see where hole will b...
Page 10 - Installing the Chimney System; Make sure the; Installing the Firestop Spacer; ELBOW STRAP; Attic Installation
10 CR Series Woodburning Fireplaces 20001316 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 13. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locke...
Page 11 - is
11 CR Series Woodburning Fireplaces 20001316 Hole sizes listed in Figure 10 for angled firestop spac-ers provide minimum required air space to chimney pipe for ceiling thickness up to 8” (203mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8” (203mm), adju...
Page 12 - Cut and Frame Roof Hole; horizontal; Install Remainder of Chimney Sections; Ten Foot Rule; Installing Top Housing or Termination; Finishing; Side View; Air Spaces; Front View
12 CR Series Woodburning Fireplaces 20001316 Cut and Frame Roof Hole Size of roof hole varies with the type of chimney termination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole.There must be an air space (1 ¹⁄₂ " (38mm) with ...
Page 13 - Framing surround; Top View
13 CR Series Woodburning Fireplaces 20001316 MA81 Fig. 19 Combustible mantel clearances. MA81 rev. 8/5/97 1 ¹⁄₂ " Ref. Combustible materials are permitted within a shaded area shown in Figure 20, titled Minimum Wall Clearances. * * * * 12” from top of fireplace opening** 6” from top of fireplace o...
Page 14 - Finish Wall; EXAMPLES OF INSULATION:; Hearth Installation; Example for Common Brick
14 CR Series Woodburning Fireplaces 20001316 Finish Wall Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12” (305mm) from the top of the fireplace opening. Do not install a mantel face plate less than 6” (159mm) from top of fireplace opening. (Fig. 18)...
Page 15 - Min. Hearth Extension; Min. wall covering distances; Minimum Hearth Extension Dimensions; Sealing; Sealing Sides; COMMON MATERIALS AND FACTORS
15 CR Series Woodburning Fireplaces 20001316 FE106 Min. Hearth Extension 6/22/99 djt FE105 Min. wall covering distances 3/3/99 djt Proposed Perpendicular Side Walls Model CR36L CR36R Min. Dist. with SP40 A 12” Min. Dist. to Non-protected Wall B 16” Minimum Hearth Extension Dimensions FE105 Wall Shie...
Page 16 - Installing Line for Gas Logs; Local codes may require removal of flue
16 CR Series Woodburning Fireplaces 20001316 Installing Line for Gas Logs Majestic Fireplaces CR36R/L Series fireplace is de-signed to accept a 1/2” gas line for an approved gas appliance. (CFM Corporation manufactures a wide variety of gas logs for use in Majestic Fireplaces.) Have the appliance ins...
Page 17 - Parts page; CR36R/L Woodburning Fireplace
17 CR Series Woodburning Fireplaces 20001316 325 Parts page CR36L/R 3/17/99 djt 1 2 3 4 5a 6 10 9 8 7 a b c 5b CR36R/L Woodburning Fireplace Item/Model Number CR36L CR36R 1. Flue Damper Blade RP102 RP102 2. Actuator 20001587 20001587 3. Screen Assembly (three per fireplace) 7554338 7554338 4. Screen ...
Page 18 - Accessories; owner’s home insurance.; be installed before the fire-; Outside Air Kit; Hearth extension; Hearth Extension Material
18 CR Series Woodburning Fireplaces 20001316 Accessories The following accessory parts can be obtained from Majestic Fireplaces Dealer. The fan kit, top terminations, out- side air kit, glass doors and hearth patching kits are supplied with installation instructions packaged with the unit. Should yo...
Page 19 - Accessory; Top Housings; Chimney Support; housings extensions
19 CR Series Woodburning Fireplaces 20001316 Accessory Description Model No. P325g firestop SKFS2A SKFS6A 3/4/99 djt Firestop Used to support the chimney at each 30 feet of vertical height above the hearth and at every 6 feet of inclined chimney run. Each support adds 2 ¹⁄₂ inches to chimney length....
Page 20 - Chimney elbows; Contemporary flashing
20 CR Series Woodburning Fireplaces 20001316 Accessory Description Model No. P325l Chimney section SK8 3/6/99 djt Required for contemporary round top termination on the roof to prevent rain entry. Used to build “SK” chimney systems. Used to develop 30° offset chimney systems. (Elbows packed 2 per ca...
Page 21 - Adapter Kit; Chase top housings; Accessories for Canada
21 CR Series Woodburning Fireplaces 20001316 Accessory Description Model No. P325q Chase Top CT100 3/5/99 djt Used to terminate chimney at the top of a chase. Flashing is not included. Appropriate adapter is required. See Sections 2 and 3. Used to terminate Type “SK8” 2 wall chimney at the top of a ...
Page 23 - LIMITED WARRANTY & 30 YEAR PROTECTION PLAN; For MAJESTIC FIREPLACES
23 CR Series Woodburning Fireplaces 20001316 LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its MAJESTIC FIREPLACES® Pre-Engineered Fireplace (“Fireplace”) and the CFM Corpora-tion supplied firegrate, glass doors, out...
Page 24 - CFM Corporation
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com CFM Corporation