Page 2 - TABLE OF CONTENTS; Thank you and congratulations on your purchase.
- 2 - TABLE OF CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possibl...
Page 3 - INSTALLATION AND OPERATING INSTRUCTIONS
- 3 - IMPORTANT:PLEASE REVIEW THE FOLLOWINGCAREFULLY Remove any plastic from trim parts before turningthe fireplace ON. It is normal for fireplaces fabricated of steel to giveoff some expansion and/or contraction noisesduring the start up or cool down cycle. Similarnoises are found with your furnace...
Page 4 - FIREPLACE DIMENSIONS; Framing Dimensions; Appliance Dimensions
- 4 - A 36" 914mm B 34 1/4" 870mm C 21" 533mm D 33" 838mm E 24" 610mm F 16" 406mm G 37 1/4" 946mm I 7 1/8" 181mm J 6 3/4" 171mm K 10" 254mm L 13 1/2" 343mm M 39 3/4" 1010mm N 55 1/4" 1403mm O 28 1/8" 714mm ROD 16 1/2" 419mm ROW 36 1/2" ...
Page 5 - MANTEL CHART; Choose fireplace location.; FRAMING AND FINISHING; ADJUSTABLE DRYWALL STRIP; (Do not cover louvres; FINAL FINISHING
- 5 - Ref. Mantel Ref. Mantel From Mantel Leg from Depth Top Louvre Fireplace Side V 10" (254 mm) A 12" (305 mm) 10" (254mm) W 8" (203 mm) B 10" (254 mm) 8" (203mm) X 6" (152 mm) C 8" (203 mm) 6" (152mm) Y 4" (101 mm) D 6" (152 mm) 4" (101mm) Z 2" ...
Page 6 - HEARTH; GAS INLET & MANIFOLD PRESSURES; Input Minimum; GAS SPECIFICATIONS; Vented Gas Fireplace Heaters.
- 6 - Do not use this fireplace if any part of it hasbeen under water. Immediately call a qualifiedservice technician to inspect the fireplace andreplace any part of the control which has beenunder water. Cold climate installation recommendation:When installing this unit against a non-i n s u l a t ...
Page 7 - REMOTE SWITCH INSTALLATION; ALTERNATE SWITCH LOCATION:; GAS LINE INSTALLATION; consult the current
- 7 - PILO T TPTH TP TH SIT VALVE REMOTE SWITCH INSTALLATION 1. Thread wire through the electrical knockout located oneither side of fireplace.. Do not cut wire or insulation onmetal edges. Ensure that wire is protected. Run theother end to a conveniently located wall receptaclebox. 2. Attach wire t...
Page 8 - clearance to outside comer see next page; GENERAL VENTING
- 8 - V V V V V V V V V X X X D E B B B C B M B A J K A F L G G TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED) H I Fixed Closed Fixed Closed Openable Openable Fixed Closed G G N N Your fireplace is approved to be vented either throughthe side wall, or vertical thr...
Page 9 - Termination Clearances; Recessed Location; BEAD LOCATION; GENERAL INFORMATION ON ASSEMBLING
- 9 - Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A =Combustible 6"(152mm) Noncombustible 2"(50mm) B =Combustible 6"(152mm) Noncombustible 2"(50mm) A Balcony - with no side wall G = Combustibl...
Page 10 - VERTICAL SIDEWALL APPLICATIONS; fireplace to the face of the outer wall.
- 10 - For some installations, it may be desireableto have some amount of the horizontal ventrun immediately after the fireplace. A verti-cal rise must be used but can be locatedanywhere in the vent system, to meet theperimeters identified in the venting graph. *IMPORTANT* Minimum clearance between ...
Page 11 - Total; HOW TO USE THE VENT GRAPH; EXAMPLE; VERTICAL SIDEWALL VENTING GRAPH; SEE PAGE 14 FOR VENTING
- 11 - If a 90 degree elbow is used in the horizon-tal vent run (level height maintained) themaximum horizontal vent length is reducedby 36 inches. Fig. 15. This does not apply ifthe 90 degree elbows are used to increaseor redirect a vertical rise. The maximum number of elbow degrees in a system is2...
Page 12 - STEP 1; VERTICAL SIDEWALL INSTALLATION; STEP 2; VERTICAL SIDEWALL APPLICATION; STEP 4
- 12 - COMBUSTIBLE WALLS (Fig. 18): Cut a 9-3/8"H x 9-3/8"W (240mm x 240 mm) hole through the exterior wall and frame as shown.NON-COMBUSTIBLE WALLS (Fig. 19): Hole opening must be 7.5" (190 mm) in diameter. (240mm) 9- 3/8 " 9- 3/8 " (240mm) 7- 1/2 " (190mm) Vent Opening — Co...
Page 15 - Locate your fireplace.; VERTICAL THRU THE ROOF INSTALLATION
- 15 - TYPICAL STRAIGHT-UP INSTALLATION 40 FEET (12.2m) ATTIC INSULATION SHIELD JOISTS ROOF VENT TERMINATION ATTIC INSULATION ROOF SUPPORT STORM COLLAR ROOF FLASHING 2' Min. CEILING JOISTS Fig. 33 1. Locate your fireplace. 2. Plumb to centre of the (4") collar from ceiling above andmark position...
Page 16 - CRIMPED ENDS VENTING COMPONENTS
- 16 - CRIMPED ENDS VENTING COMPONENTS Starter Kit -Model 7DVSK - Sidewall Venting Starter Kit - Model 7DVSKV - Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitchfor 7DVSKV-B order 7/12 to 12/12 roof pitchfor 7DVSKV-F order flat roof Starter Kit - Model 7DVSKS -Snorkel Kit for Below Grade I...
Page 17 - Screw Holes; Crimped pipe and new twist lock pipe.
- 17 - GENERAL INFORMATION ON ASSEMBLING THE TWIST LOCK VENT PIPES When using CFM Majestic twist lock pipe it is not neces-sary to use silicone to seal the twist lock joints. The onlyareas that need silicone are the collars on the fireplace,the telescoping pipe (if used) and the horizontal termina-t...
Page 19 - SEE PAGE 21 FOR VENTING
- 19 - HOW TO USE THE VENT GRAPH 1. Determine the height of the centre of the horizontalvent pipe exiting through the outer wall. Using thisdimension on the Sidewall Vent Graph (Fig. 39),locate the point it intersects with the slanted graphline. 2. From the point of this intersection, draw a vertica...
Page 21 - BELOW GRADE INSTALLATIONS; Ensure sidewall venting clearances are observed.
- 21 - STEP 7 Support the horizontal pipes every 36 inches (914mm)with metal pipe straps. Make sure that the horizontal ventpipe is installed on a level horizontal plane. STEP 8 Recheck the fireplace to make sure that it is levelled,properly positioned, and nailed or screwed to the floor. If applied...
Page 22 - VERTICAL THROUGH THE; elbows may be used within the horizontal
- 22 - TYPICAL STRAIGHT-UP INSTALLATION 40 FEET (12.2m) ATTIC INSULATION SHIELD JOISTS ROOF VENT TERMINATION ATTIC INSULATION ROOF SUPPORT STORM COLLAR ROOF FLASHING 2' Min. CEILING JOISTS FOUNDATION RECESS SNORKEL SCREWS WALL SCREWS SHEET METAL WATERTIGHT SEAL AROUND PIPE If the foundation is reces...
Page 24 - TWIST LOCK VENTING COMPONENTS
- 24 - TWIST LOCK VENTING COMPONENTS Starter Kit -Model 7TDVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitchfor 7TDVSKV-B order 7/12 to 12/12 roof pitchfor 7TDVSKV-F order flat roof Starter Kit - Model 7TDVSKS -Snorkel Kit for Below Gra...
Page 25 - GLASS FRAME REMOVAL; Let the fireplace cool if it has been operating.; OPERATING INSTRUCTIONS; GENERAL GLASS INFORMATION; Care must be taken to avoid breakage of the glass.; LOUVRE REMOVAL
- 25 - GLASS FRAME REMOVAL 1. Shut off gas. 2. Let the fireplace cool if it has been operating. 3. Remove top louvre. (See Louvre Removal) 4. Open the lower louvre assembly. 5. Release the two clamps at the bottom of the windowframe by pulling down on the clamp handles. 6. Lift off the glass frame a...
Page 26 - LAVA ROCK; Under no circumstances should this; INSTALLATION OF LOGS; Remove logs from the packaging.
- 26 - HI OFF PILOT LO LAVA ROCK The lava rock provided with this fireplace must be placedon the firebox base on either side of the burner assem-bly. Under no circumstances should this lava rock be placed on any part of theburner assembly. INSTALLATION OF LOGS Fig. 58 FLAME ADJUSTMENT For fireplaces...
Page 27 - LOGS MAY BE HOT; FLAME CHARACTERISTICS; SIT PILOT
- 27 - The burner and control system consists of: • burner tube • gas orifices • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasionalcheckup and cleaning and some may require adjustment.If repair is necessary, it should be performed by a qualified...
Page 28 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; TO TURN OFF GAS TO FIREPLACE; LIGHTING AND OPERATING INSTRUCTIONS; LIGHTING INSTRUCTIONS; EURO SIT
- 28 - 4. Push in gas control knob slightlyand turn clockwise to "OFF". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressingthe piezo spark ignitor until a flame appears.Continue to hold the contr...
Page 29 - START; CHECK; TROUBLE SHOOTING THE GAS CONTROL SYSTEM; HONEYWELL MILLIVOLT VALVE
- 29 - • GAS SUPPLY ON • SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED.• ALL WIRING CONNECTIONS• REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES• THERMOPILE N...
Page 30 - SIT 820 NOVA MILLIVOLT VALVE; GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK
- 30 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM SIT 820 NOVA MILLIVOLT VALVE START CHECK GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK GAS SUPPLY ON • SHUTOFF VALVE OPEN• CONFIRM GAS HOOK-UP LIGHT PILOT WITH PIEZO IGNITION • ELECTRODE GAP MIN. 1/8"• ELECTRODE CRACKED• ELECTRODE CABLE ATTACHED• PIE...
Page 31 - REPLACEMENT PARTS LIST; ESCRIPTION; S E E R A T I N G P L A T E F O R O R I F I C E S I Z E
- 31 - REPLACEMENT PARTS LIST D ESCRIPTION BHDR36 1. Log Set Complete 10001818 1a. Log Front BH1 1b. Log Rear BH2 1c. Log Top Left BH3 1d. Log Top Right BH4 2. Lava Rock (Package) 10001454 3. Burner Tube Assembly 10001811 4a. Orifice Burner (Nat) S E E R A T I N G P L A T E F O R O R I F I C E S I Z...
Page 32 - REPLACEMENT PARTS
- 32 - REPLACEMENT PARTS 27 26 24 25 22 4 a/b 17 31 32 33 30 30 29 21 23 19 a/b 5 a/b 34 2 28 36 31 12 LO HI PILOT ADJ PILOT ON OFF 20 a/b 18 8 a/b 3 6 a/b 16 11 9 15 13 7 a/b 10 15 14 #1 - COMPLETE LOG SET 1c 1d 1b 1a
Page 33 - OPTIONAL FAN KIT - FK24; WIRING INSTRUCTIONS; OPTIONAL BAY WINDOW; Remove existing bottom louvre and hinges from fire-
- 33 - 1. Slide fan assembly from the left side into fireplaceopening, line up mounting holes with screw studs onback of fireplace and fasten with #10-24 hex nuts. 2. Install thermal sensor on bottom of firebox using#10-24 hex nuts. 3. (Option A) - Place electronic fan speed control boxon bottom of ...
Page 34 - To install the Frame Window Screen:; OPTIONAL REMOTE CONTROL
- 34 - OPTIONAL CERAMIC REFRACTORY INSTALLATION 6. Hang Bay Window Frame assembly over existing glass frame. Do not remove existing glass frame 7. Re-install top louvre assembly. Remove all plastic from brass trims 8. Open the Bottom Bay Louvre door and screw two (2) self tapping screws (as per step...