Page 2 - 60DVS Series Direct Vent Fireplaces; Installation & Operating Instructions; This appliance may be installed in an aftermarket, per-; Proposition 65 Warning:; Locating Your Fireplace; locate fireplace
3 360DVS Series Direct Vent Fireplaces 10006326 This gas appliance should be installed by a qualified installer in accordance with local building codes and current CSA-B149.1 Installation Codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the installation...
Page 3 - 60 DVS Series Direct Vent Fireplaces; Fireplace Dimensions - 360DVS2; Fireplace specifications—360DVS2; Rear Vent Configuration
4 360 DVS Series Direct Vent Fireplaces 10006326 J J K K H D A E B I E A F C H 6326 360DVS2 top vent specs Electrical Access Gas Line Access Electrical Access Gas Line Access K J J K J J G J J K K H D A E B E A F C K H 6326 360DVS2 rear vent specs G I Electrical Access Gas Line Access Electrical Acc...
Page 5 - Framing Dimensions - 360DVS2; Fireplace framing dimensions—360DVS2
6 360 DVS Series Direct Vent Fireplaces 10006326 ROH ROD ROW CFM121 360DVS2 REAR VENT CONFIGURATION 8/10/00 Framing Dimensions - 360DVS2 CFM122 360DVS2 - TOP VENT CONFIGURATION 8/10/00 ROD ROH ROW Rear VentConfiguration Top VentConfiguration CFM121 CFM122 Framing Dimensions Ref. Rear Vent Configuration...
Page 6 - Rear Vent Confiration; Framing Dimensions
7 360DVS Series Direct Vent Fireplaces 10006326 CFM123_360DVS3_dims_RV2 REAR VENT CONFIGURATION 8/10/00 rev. 8-23-02 rjs ROD ROW ROD ROH ROH ROH ROD 360DVSL 360DVS/3/L/R 360DVS3 360DVSR CFM124_360DVS3_TV2 TOP VENT CONFIGURATION 8/10/00 rev. 8-23-02 rjs ROD ROD ROH ROW ROH ROH ROD 360DVSL 360DVS/3/L/...
Page 7 - Mantels; Combustible mantel minimum installation.; Top View; Combustible mantel leg minimum installation.; Hearth
8 360 DVS Series Direct Vent Fireplaces 10006326 CFM170 DV Builder Front View O N M L K Appliance Top .........................................0” (0 mm) to standoff Bottom ..................................................... 0” (0 mm) Vent End ....................... 1/2” (13 mm) to rear panel Nonv...
Page 8 - Final Finishing; Frame in the fireplace with a header across the top.; ing to constructed frame, not the appliance.; Gas Inlet & Manifold Pressures; Natural; Inlet Minimum; Input; Gas Specifications; Vented Gas Fireplace Heaters; Gas Line Installation; Gas shutoff valve and flex connector.
9 360DVS Series Direct Vent Fireplaces 10006326 Final Finishing 1. Choose the unit location.2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws or nails. Holes to secure the unit to the floor are located behind the access door grille on the left and right sides of the...
Page 9 - EB-1 Electrical Junction Box Connection; Canadian Electrical Code.; Remote ON/OFF Switch Installation; TP; Remote switch wiring diagram for R models.; Alternate Switch Location
10 360 DVS Series Direct Vent Fireplaces 10006326 The gas control is equipped with a captured-screw type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point upstream of the control.When using copper or flex connector, use only ap- proved fittings. Always provide a union w...
Page 10 - Alternate switch location.; Optional Top Vent Application; Remove screws from outer collar adapter.; remove flue cover; Remove flue cover and pipe.
11 360DVS Series Direct Vent Fireplaces 10006326 FP1430 Fig. 8 Alternate switch location. Optional Top Vent Application This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con-figuration, the appliance can be converted by following the steps be...
Page 11 - Electronic Gas Control Valve; Thread the wiring through the holes on the side; Honeywell ignition module.; There must not be any obstruction; General Venting; Location of Vent Termination
12 360 DVS Series Direct Vent Fireplaces 10006326 Electronic Gas Control Valve This appliance may be fitted with a Honeywell ignition module. Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12): 1. Thread the wiring through the holes on the side panels of the appli...
Page 12 - General Venting Information - Termination Location; Canadian Installations
13 360DVS Series Direct Vent Fireplaces 10006326 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Fixed Closed Operabl e Operable Fixed Closed V B CFM145a DV Termin Location 5/01/01 Rev. 12/05/01 sta INSIDE CORNER...
Page 13 - Termination clearances.; General Information Assembling Vent Pipes; Canadian Installations:; Venting system must be installed in accordance with the; Twist Lock Pipes; For ease of assembly, use a lubricant (Vaseline; Twist lock pipe joints.
14 360 DVS Series Direct Vent Fireplaces 10006326 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A = Combustible 6"(152mm)Noncombustible 2"(50mm) B = Combustible 6"(152mm)Noncombustible 2"(50mm) ...
Page 14 - How to Use the Vent Graph; ertical dimension from fl; Sidewall vent graph.; Rear Wall Application; Rear vent application.; Rear Wall Installation; Noncombustible walls:
15 360DVS Series Direct Vent Fireplaces 10006326 How to Use the Vent Graph The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.1. Determine the height of the center o...
Page 15 - Vent Opening for Combustible Wall; Vent Opening for Noncombustible Wall; Locate vent opening on rear wall.; Side View; Adjustable zero clearance sleeve.; Vertical Sidewall Application; When installing the appliance as a rear vent
16 360 DVS Series Direct Vent Fireplaces 10006326 VO584-100 Vent Opening 2/99 djt Vent Opening for Combustible Wall 9 ³⁄₈ ” (240mm) 10 ³⁄₈ ” (265mm) Framing Detail Vent Opening for Noncombustible Wall 7 ¹⁄₂ ” (190mm) VO584-100 Fig. 18 Locate vent opening on rear wall. CFM135 Zero Clearance Sleeve 2/...
Page 16 - Horizontal run reduction.; Vertical Side Wall Installation
17 360DVS Series Direct Vent Fireplaces 10006326 Horizontal plane means no vertical rise exists on this portion of the vent assembly. • The maximum number of 90˚ elbows per side wall installation is three (3). • If a 90˚ elbow is fitted directly on top of the fireplace flange, the maximum horizontal ve...
Page 18 - Below Grade Installation; pipe coming through the wall.; Below grade installation.; Snorkel installation / recessed foundation.
19 360DVS Series Direct Vent Fireplaces 10006326 2” (51 mm). Secure termination to the wall with screws provided, and caulk around the wall plate to weather-proof.One alternative to screwing the termination directly to the wallis the use of expanding plugs or an approved exterior construction adhesi...
Page 19 - This Gas Fireplace has been approved for:; Support straps for horizontal runs.; Maximum horizontal length:; Maximum elbow usage.
20 360 DVS Series Direct Vent Fireplaces 10006326 Vertical Through-the-Roof Application This Gas Fireplace has been approved for: • Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig...
Page 20 - port Application; Firestop and attic insulation shield.
21 360DVS Series Direct Vent Fireplaces 10006326 Vertical Through-the-Roof Installation 1. Locate your fireplace.2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut an opening equal to 9 ³⁄₈ ” x 9 ³⁄₈ ” (240 x 240mm). 4. Proceed to plumb for additional openings thro...
Page 21 - vent components; Venting Components; Vent Components; Vent components; Twist Lock Venting Components
22 360 DVS Series Direct Vent Fireplaces 10006326 584B Vent components Starter Kit 2/25/99 djt 584G Venting Components Firestop spacer 2/25/99 djt 584H Venting components attic insulation shield 2/25/99 djt 584I vent components offset support 2/25/99 djt 584F Venting Components Pipe sections 2/25/99...
Page 22 - Operating Instructions; Glass Information; Louvre removal; Remove louvre assembly top.; Window Frame Assembly Removal; remove glass frame
23 360DVS Series Direct Vent Fireplaces 10006326 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. Glass Information • The top side and top end louvres are removed by simply lifting the louvre assembly and pulling the as-sembly away from the fireplace. (Fi...
Page 23 - Glass Cleaning; Ceramic panel installation.; Log Installation; log
24 360 DVS Series Direct Vent Fireplaces 10006326 Glass Cleaning It is necessary to periodically clean glass. During start-up, condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface.Also initial pain...
Page 24 - logs; Side of Fireplace; Side of Fireplace; 60DVS log placement.; Lava Rock and Ember Material Placement; Ember Material; Flame & Temperature Adjustment
25 360DVS Series Direct Vent Fireplaces 10006326 LG320 360DVS logs B120 B121 B122 B123 B124 B126 B125 LG320 Fig. 40 360DVS log placement. Side of Fireplace V enting Side V enting Side LG321 360DVS logs opposite side B120 B121 B122 B123 B126 B125 Side of Fireplace LG321 Fig. 41 360DVS log placement. ...
Page 25 - Flame adjustment knob for SIT valve.; Flame Characteristics; Correct pilot flame appearance.
26 360 DVS Series Direct Vent Fireplaces 10006326 L O HI FP390 FLAME ADJUSTMENT KNOB 11/21/96 Turn counterclockwise to increase flame height Turn clockwise to decrease flame height Fig. 43 Flame adjustment knob for SIT valve. Flame Characteristics It is important to periodically perform a visual che...
Page 26 - Burner and Burner Compartment; Cleaning the; Maintenance; Cleaning Electronic Ignition System
34 360 DVS Series Direct Vent Fireplaces 10006326 Burner and Burner Compartment It is important to keep the burner and the burner com-partment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the inst...
Page 28 - * Ceramic Burner Tile
36 360 DVS Series Direct Vent Fireplaces 10006326 360DVS Series (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 1. Log Set (complete) 10006350 10006350 10006350 10006350 1a. Log - Rear (B120) 10006315 10006315 10006315 10006315 1b. Log - Fr...
Page 30 - BASIC WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
43 360DVS Series Direct Vent Fireplaces 10006326 BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purc...
Page 31 - Efficiency Ratings; Model; CFM Corporation
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 360DVS2RN 62.4 83 84 65 360DVS2RP 62.4 83 84 65 360DVS2EN 62.4 83 84 65 360DVS2EP 62.4 83 84 65 360DVS3RN 62.4 83 84 65 360DVS3RP 62.4 83 84 65 360DVS3EN 62.4 83 84 65 360DVS3EP 62.4 83 8...