Page 2 - Radiance Natural Vent Gas Heater; Table of Contents; Installation & Operating Instructions
2 2 Radiance Natural Vent Gas Heater 20004409 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to...
Page 4 - Stove Dimensions
4 4 Radiance Natural Vent Gas Heater 20004409 Stove Dimensions See Page 5 for Flue CollarCenterline Dimensions. 4409 Fig. 1 Radiance dimensions. R A D I A N C E 29 ³⁄₄ " (756mm) 31" (787mm) 14 ⁷⁄₈ " (378mm) 4" Inner Dia.(100mm) 4 ¹⁄₂ " (114mm) CL 28" (711mm) 5" (127mm) 9 ...
Page 5 - • Always maintain required; Stove Clearance; Fig. 3 Corner installation requirements.
5 Radiance Natural Vent Gas Heater 20004409 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2through 5 from the outer edge of the cast iron stovetop. Measure rear clearances from the rear sheet metalshroud. The Radiance heater is approve...
Page 6 - Venting Requirements and Options; Input; Gas Inlet and Manifold Pressures
6 6 Radiance Natural Vent Gas Heater 20004409 Venting Requirements and Options The Radiance must be properly connected to a listed4” (102mm) Type B venting system or to an approvedClass A masonry or factory-built chimney system. InCanada, a complete relining of Class A chimneysystems is required. Th...
Page 7 - Passing Through a; Venting Requirements; Venting Runs; = Acceptable venting configuration; (Measured from top of the unit before any elbow)
7 Radiance Natural Vent Gas Heater 20004409 Passing Through a Combustible Wall or Ceiling An approved pass-through device is always requiredwhen a vent passes through a combustible wall orceiling. Check with the maker of the vent system forthe correct listed devices that are available. A listedpass-...
Page 8 - Tools Required; WARNING; Assembly Procedures
8 8 Radiance Natural Vent Gas Heater 20004409 Tools Required • Phillips screwdriver (stub) • power drill • utility knife • reciprocating saw • metal drill bit: size 28 (.140"/3.5mm) Unpack and Set Up the Stove The Radiance is shipped on its back. Cut the shippingstraps and set stove upright. Par...
Page 9 - Fig. 12 Position fan behind rear shroud.
9 Radiance Natural Vent Gas Heater 20004409 A ST363 Rear shroudCover Plate(ShippingPosition) Fig. 11 Remove/replace rear shroud. RearShroud 1. The fan kit includes a Blower Assembly and a Rheostat Assembly, connected by a cable. (Fig. 10)The Blower Assembly mounts to the bottom rear ofthe stove, and...
Page 10 - Fig. 13 Attach rear shroud cover plate to the rear shroud.; Install the Optional Fan; Fig. 16 Attach the fan assembly to the fan bracket.
10 10 Radiance Natural Vent Gas Heater 20004409 5. Attach the fan assembly to the fan bracket provided in the finish bag. Use the #10 sheet metal screwsprovided with fan kit. Do not remove finger guardscrews. (Fig. 16) 6. Connect snapstat leads. Disconnect the snapstat module from the leads inside t...
Page 11 - Fig. 20 Attach rheostat to left side of valve.
11 Radiance Natural Vent Gas Heater 20004409 PinchGrommet toRemove Snapstat Module Snapstat Bracket ST670 Fig. 17 Remove the snapstat and grommet from the bracketand insert the grommet into the inner shroud. Slot OuterShroud Inner Shroud Slot ST194 Fig. 18 Position the fan to engage the inner shroud...
Page 12 - Venting System Assembly
12 12 Radiance Natural Vent Gas Heater 20004409 ST373 Fig. 23 Attach the B-vent adapter to the flue. do not need to be fastened at each joint, other than slipsections. The decorative pipe need not be fastened tothe locating bracket on the stove. If the layout includesa slip section, this should be t...
Page 13 - Connect the Gas Supply Line; do not over apply. NEVER test with an open; CAUTION; Run wires down back of stove, under bottom of rear; Fig. 25 Attach switch assembly to rear shroud.; Burner Information
13 Radiance Natural Vent Gas Heater 20004409 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to thefirebox, to confirm that you have the appropriate fireboxfor the type of fuel to be used. The Radiance may beconverted from one gas to another using the appropri-ate Fuel C...
Page 14 - Install Rear Bracket and Log Set; Thermostat; Install the Mesh and Grille; Fig. 27 Radiance firebox and rear log bracket.
14 14 Radiance Natural Vent Gas Heater 20004409 Install Rear Bracket and Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAM-AGED LOGS. 2. Install the left rear log by placing it on the rear log bracket at the back of the firebox. (Fig. 28) The left...
Page 15 - Fig. 28 Install the left and right rear logs and the right log.; Top View
15 Radiance Natural Vent Gas Heater 20004409 LG156 Fig. 28 Install the left and right rear logs and the right log. DecorativeGrate Right Log Right Rear Log Left Rear Log LeftBracket RightBracket Fig. 30 Place lava rock on top of burner just behinddecorative grate. Left Rear Log Right RearLog Decorat...
Page 16 - Operable Doors; Operation; Your First Fire; LO; Flame Characteristics
16 16 Radiance Natural Vent Gas Heater 20004409 Operable Doors The Radiance is shipped with the operable door front.The stove may be operated with the doors either openor closed. To open the front doors, insert the handleinto the door latch stub and turn it to the right and up.(Fig. 31) When not in ...
Page 17 - FOR YOUR SAFETY READ BEFORE LIGHTING; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
17 Radiance Natural Vent Gas Heater 20004409 3. Open control access panel.4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.2. Turn off all electrical power to the fireplace.3. For MN/MP/T...
Page 18 - Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
18 18 Radiance Natural Vent Gas Heater 20004409 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, checkgap at electrode and pilot - it should be 1/8” to have astrong spark. B. Defe...
Page 19 - Fuel Conversion Instructions; Fig. 37 Attach the gas line to the left side of the valve.; Conversion Precautions; Fig. 39 Remove and replace injector orifices.
19 Radiance Natural Vent Gas Heater 20004409 Fuel Conversion Instructions WARNING! This conversion kit shall be installedby a qualified service agency in accordance withthe manufacturer’s instructions and all applicablecodes and requirements of the authority havingjurisdiction. If the information in...
Page 20 - Conversion to Natural Gas; Table 2. Injector Orifice Size Matrix; Model; RNVOD; Table 3. Air Shutter Adjustment; NOTE: It is very critical to keep the left burner leg,
20 20 Radiance Natural Vent Gas Heater 20004409 Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 000-5009 #51 30000449 #40 20004263 25,000 35,000 Conversion to LP Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 000-5010 #57 20004587 #54 20000130 27,...
Page 21 - Maintenance
21 Radiance Natural Vent Gas Heater 20004409 Maintenance Your Radiance Gas Heater will provide years of servicewith minimal upkeep. The following procedures will helpensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspectedann...
Page 22 - Gasket Replacement; Determine the correct length of gasket by laying it; Inspect the Vent System Annually; Fig. 45 Release the latches to remove the glass frame.
22 22 Radiance Natural Vent Gas Heater 20004409 Gasket Replacement The Radiance Gas Heater uses a ‘tadpole’ type gasketto seal between the glass panel and the frame. In time,this gasket can become brittle and compressed andshould be replaced. New gasket is available from yourdealer. Shut off the gas...
Page 23 - C WIRE OR ITS EQUIVALENT.; Schematic Diagram; Wiring Diagrams
23 Radiance Natural Vent Gas Heater 20004409 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200 ° C WIRE OR ITS EQUIVALENT. FAN JUNCTION BOX FAN POWER CORD Strain Relief Chassis Ground BLK GRN GRN WHT ON / OFFRheostat Chassi...
Page 25 - Description
25 Radiance Natural Vent Gas Heater 20004409 Radiance Natural Vent (RNVOD) (continued) Models: 3340 thru 3349, 3355, 3356 Ref. Description RNVOD 1. Log Set -RDVOD/RNVOD 20004184 1a. Right Rear Log RDNOD/RNVOD 20004185 1b. Left Rear Log RDVOD/RNVOD 20004186 1c. Right Log RDVOD/RNVOD 20004187 2. Manif...
Page 27 - Optional Accessories
27 Radiance Natural Vent Gas Heater 20004409 Optional Accessories Fan Kits FK26 Fan The FK26 fan kit helps distribute heated air from withinthe firebox out into the room. The fan is controlled by asnapstat that turns power on and off as the fireboxtemperature rises above and falls below a presettemp...
Page 30 - IF WARRANTY SERVICE IS NEEDED...; ) DO NOT ATTEMPT TO DO ANY SERVICE WORK; LIMITED LIFETIME WARRANTY
30 30 Radiance Natural Vent Gas Heater 20004409 BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively asthe Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defectsfor a period of one year from the dat...
Page 31 - SI UN SERVICE SOUS GARANTIE EST REQUIS...; GARANTIE À VIE LIMITÉE
31 Radiance Natural Vent Gas Heater 20004409 GARANTIE DE BASE La société CFM Specialty Products (ci-après la « Société ») garantitvotre nouveau poêle/foyer au gaz Vermont Castings ou Majesticcontre tous défauts de fabrication et de matières premières pour unepériode d’un an à compter de la date d’ac...
Page 32 - CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products