Page 2 - Dutchwest Natural Vent Gas Heater; Table of Contents
2 Dutchwest Natural Vent Gas Heater 30002008 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow ...
Page 3 - Completion of sale, nor for purpose of resale,; Installation & Operating Instructions
3 Dutchwest Natural Vent Gas Heater 30002008 The Dutchwest Natural Vent Room Heater, Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Al-titudes. The install...
Page 4 - CL; Dutchwest; Dutchwest dimensions.; Dutchwest Natural Vent Gas Heater Dimensions
4 Dutchwest Natural Vent Gas Heater 30002008 CL Valve Inlet CL Valve Inlet 2008 Dutchwest NV dimensions 6/23/03 17" (419 mm) 23" (584 mm) 28 ��� " (721 mm) 4 ��� " (111 mm) 6 ��� " (172 mm) 12 ��� " (318 mm) 24 ��� " (622 mm) See Page 5 for Flue Collar Centerline Dimensio...
Page 5 - Stardance; SNV
5 Dutchwest Natural Vent Gas Heater 30002008 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the sheet metal rear skirt.The...
Page 6 - Venting Requirements and Options; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural; Dutchwest Natural Vent; Nat
6 Dutchwest Natural Vent Gas Heater 30002008 Venting Requirements and Options The Dutchwest must be properly connected to a listed 4” (102 mm) Type B venting system or to an approved Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney sys-tems is requir...
Page 7 - Passing Through a; It is essential to seal between the ceil-; Vent termination window.; Venting Requirements; Venting Runs; NOTE: When venting staight vertical, without an; (Measured from top of the unit before any elbow; Ceiling pass thru; A ceiling pass-through, with decorative pipe around the
7 Dutchwest Natural Vent Gas Heater 30002008 Passing Through a Combustible Wall or Ceiling An approved pass-through device is always required when a vent passes through a combustible wall or ceil-ing. Check with the maker of the vent system for the correct listed devices that are available. A listed...
Page 8 - attach snapstat; Front View; Install the Optional Fan
8 Dutchwest Natural Vent Gas Heater 30002008 ST194 attach fan to shroud 11/99 Outer Shroud Slot Inner Shroud Slot ST194 Fig. 11 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws. ST720 attach snapstat 8/02 Left Air Duct Fan Inner Shroud ST720 F...
Page 9 - Install the snapstat and connect the extension wire; Attach rheostat to left side of valve.; Venting System Assembly; Use a template to locate the bracket for decorative
9 Dutchwest Natural Vent Gas Heater 30002008 ST671 attach snapstat Snapstat Left Air Duct ST671 Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection. 9. After slid...
Page 10 - Connect the Gas Supply Line; Gas connection should be made in ac-; NEVER test with an open; Light the pilot according to the directions on; CAUTION; Install decorative pipe over the B-vent pipe.
10 Dutchwest Natural Vent Gas Heater 30002008 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Dutchwest may be converted from one gas to another using the appropri-ate Fuel...
Page 11 - Burner Information; In order to connect Natural Gas,; Install ON/OFF Switch; attach switch assy; Attach switch assembly to rear shroud.; attach switch; Attach switch wires to valve.; Install the Log Set; Thermostat
11 Dutchwest Natural Vent Gas Heater 30002008 Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a CFM Corporation Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model. Conversion instructions are provided w...
Page 12 - Install the Stove Front; handle assy; Insert handle stub into hole in front. Secure with 3/8”; Install the front plate.; DW
12 Dutchwest Natural Vent Gas Heater 30002008 Install the Stove Front Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 23)The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and...
Page 13 - Operation; Your First Fire; Pilot Assembly location.; Correct pilot flame pattern.; Pilot flame
13 Dutchwest Natural Vent Gas Heater 30002008 Operation Your First Fire Read these instructions carefully and familiarize your-self with the burner controls. Locate the pilot assembly, Figure 25. Follow the lighting instructions on Page 14 exactly. During the first fire, it is not unusual to smell som...
Page 14 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
14 Dutchwest Natural Vent Gas Heater 30002008 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. For MN/MP/TN/TP ...
Page 15 - Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
15 Dutchwest Natural Vent Gas Heater 30002008 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark. B. Defe...
Page 16 - Conversion Precautions; “OFF”; Conversion Procedure; Fuel Conversion Instructions; Attach the gas line to the left side of the valve.; Jefferson; Remove rear log bracket and left and right log
16 Dutchwest Natural Vent Gas Heater 30002008 Conversion Precautions Conversion must be completed only by qualified per-sonnel. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAU- TION: Allow stove to cool c...
Page 17 - Gas Conversion; Remove pilot orifice.; injector orifice
17 Dutchwest Natural Vent Gas Heater 30002008 CO105a gas conversion Pilot 1/28/00 djt Pilot Hood Pilot Bracket CO105a Fig. 31 Remove pilot hood. CO106a DV360/580 Gas Conversion Pilot2 1/28/00 djt Index Tab Snap Ring Allen Wrench CO106a Fig. 32 Remove pilot orifice. • Remove pilot orifice with allen wr...
Page 18 - Conversion to LP; Table 2. Injector Orifice Size Matrix
18 Dutchwest Natural Vent Gas Heater 30002008 Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5022 #69 / .029” 30000513 #54 / .055” 20000130 21,500 28,000 3/8” Open Conversion to Natural Gas Input (BTU/h) Air Shutter Kit # Front Part # Rear Part ...
Page 19 - Maintenance; DO NOT; painted surfaces; Remove the Stove Front.
19 Dutchwest Natural Vent Gas Heater 30002008 Maintenance Your Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspecte...
Page 20 - Gasket Replacement; Determine the correct length of gasket by laying it; Inspect the Vent System Annually; Correct flame pattern.; Release the latches to release the glass frame.; glass gasket detail; Wrap the gasket material around the outside edge of
20 Dutchwest Natural Vent Gas Heater 30002008 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.Shut off the g...
Page 21 - Safety Limit Switch wiring.; rdv connections diag.; Schematic Diagram; Wiring Diagrams; On/off switch and optional thermostat circuit.; wiring
21 Dutchwest Natural Vent Gas Heater 30002008 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIVALENT. ST665 Fig. 41 Safety Limit Switch wiring. Ther m ocoupl e Safety Limit Switch Valve ST665 Safety Lim...
Page 22 - Part Number; SDV30 Log Set Assembly
22 Dutchwest Natural Vent Gas Heater 30002008 Dutchwest Natural Vent Gas Heater Models 2467, 2468 Ref. Description Part Number 1. SDV30 Log Set Assembly 20003458 1a. Rear Log 20003459 1b. Right Log 20003460 1c. Left Log 20003461 2. Small Lava Rock Package 57897 3. Top, NV DW Gas 30002005 4. Grille, ...
Page 24 - Decorative Rings; Optional Accessories Available; Fan Kits
24 Dutchwest Natural Vent Gas Heater 30002008 Decorative Rings 4” brass or black rings are available to add a decorative touch to the exposed stove pipe. Model Description 4FSDRB/4 4” Black Rings (4) 4FSDRP/4 4” Polished Brass Rings (4) Outside Air Adapter An outside air adapter, #5076, may be added...
Page 27 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
27 Dutchwest Natural Vent Gas Heater 30002008 BASIC WARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject ...
Page 28 - Efficiency Ratings; Model; CFM Corporation
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2467 51.4 2468 51.4 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com CFM Corporation