Page 2 - TABLE OF CONTENTS; NOTICE
TABLE OF CONTENTS TC IMPORTANT SAFETY INFORMATION ............................................... .....3-4 PRODUCT FEATURES..........................................................................................4 SPECIFICATIONS .........................................................................
Page 3 - IMPORTANT SAFETY INFORMATION; INSTALLER: Please leave these instructions with the owner.; ARNING
IMPORTANT SAFETY INFORMATION 3 INSTALLER: Please leave these instructions with the owner. OWNER: Please retain these instructions for future reference. IMPORTANT: Read these instructions carefully before installing or trying to operate this heater. WARNING: Any change to this heater or its controls ...
Page 5 - SPECIFICATIONS; CAUTION; CONTENTS
SPECIFICATIONS Natural GasManifold Pressure Setting 4" w.c.Gas Inlet Pressure Maximum 10-1/2" w.c.Minimum 5" w.c. Gas Rate Number Model Number Type Max BTU/Hr Min BTU/Hr of Burners 9830N Manual 30,000 8,000 2 Propane / LPGNote: An external regulator is required to reduce supply pressure ...
Page 6 - ITEMS REQUIRED FOR INSTALLATION; American National Standards Institute, Inc.
6 ITEMS REQUIRED FOR INSTALLATION ITEMS REQUIRED FOR INSTALLATIONEnsure that the following items are available before proceeding with installation: • External regulator (for propane/LPG only) • Manual shutoff valve • Piping which complies with local codes • Sediment trap • Pipe sealant approved for ...
Page 7 - INSTALLATION; FIGURE 3. Minimum Clearances
INSTALLATION The following formula can be used to determine the maximumheater rating per the definition of unconfined space: BTU/HR = (L1+L2) Ft x (W) Ft x (H) Ft x 1000 50 Consider two connecting rooms with an open area between,with the following dimensions:(See Fig. 2, Example) L1=15-1/2 Ft., L2=1...
Page 8 - GAS CONNECTION; FIGURE 4. Gas Connection
GAS CONNECTION NOTICE CAUTION IMPORTANT: Loosen the pipe adapteron the flex tube before installing to thesystem piping. FIGURE 4. Gas Connection CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. If the gas supply isdifferent, DO NOT INSTALL the heater. Contact your ...
Page 9 - FIGURE 6. Pressure Test Point Location; FIGURE 5. Rear View of 9830 Vent-Free Gas Heater
GAS CONNECTION 9 GAS PRESSURE CHECK The heater regulator controls the burner pressure which should be checked at the pressure test point located on theright side of the main control and is accessible from the side of the gas log assembly (see FIGURE 6). The pressure should be checked with the heater...
Page 10 - REMOVING FRONT SCREEN; FIGURE 8. Log Set Assembly; LOG ASSEMBLY
10 REMOVING FRONT SCREEN W ARNING FRONT SCREENThe front screen must be in place at all times when the appliance is operating. Do not obstruct the screened openingsof the heater. The positioning of the logs is critical to the safe and clean operation of this heater.Sooting and other problems may resu...
Page 11 - OPERATING INSTRUCTIONS; WHAT TO DO IF YOU SMELL GAS; FOR YOUR SAFETY READ BEFORE LIGHTING
11 OPERATING INSTRUCTIONS Avoid any drafts that alter the burner flame patterns. Do not allow fans to blow directly into the heater. Do not placea blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting andimproper burning will occur. This vent-fr...
Page 12 - LIGHTING INSTRUCTIONS; Meritik
12 OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS 1. Open access door. 2. Set front burner to Min. and turn off the rear burner by depressing knob and rotating clockwise until stop. 3. Unplug all electric power (optional blower) if service is to be performed. 4. Push in gas control knob slightly and t...
Page 14 - FLAME APPEARANCE; FIGURE 11. Flames - Natural Gas and LP Gas
14 CLEANING / SERVICING Periodic Cleaning • Do not use cleaning fluid to clean logs or any part of heater.• Logs - Brush with soft bristle brush or vacuum with brush attachment.• Vacuum loose particles and dust from the front and rear burner, control, and piezo.• Inspect burner's and air intake hole...
Page 15 - HEATER ASSEMBLY REPLACEMENT PARTS
15 HEATER ASSEMBLY REPLACEMENT PARTS 1 2 3 4 5 6 7 8 11 10 9 12 13
Page 16 - PARTS LIST FOR HEATER ASSEMBLY; KEY
16 PARTS LIST FOR HEATER ASSEMBLY KEY PART # DESCRIPTION QTY. 1 69114 CABINET TOP 1 2 69104 FIREBOX BACK WELDMENT 1 3 24535 FIREBOX TOP 1 4 24538 INSIDE BACK 1 5 69066 FIREBOX WELDMENT 1 6 24534 FIREBOX BOTTOM 1 7 69067 PEDESTAL WELDMENT 1 8 24530 PEDESTAL BASE 1 9 24457 CONTROL DOOR 1 10 89336 BRAS...
Page 17 - BURNER & LOG ASSEMBLY
17 BURNER & LOG ASSEMBLY 5 16 15 6 8 9 2 3 7 4 10 11 17 1 19 18 A B C D 20 13 14 12
Page 18 - PARTS LIST FOR GAS LOG ASSEMBLY
18 PARTS LIST FOR GAS LOG ASSEMBLY KEY PART # DESCRIPTION QTY. 1 24610 BURNER PLATE 1 2 24611 CONTROL BRACKET 1 3 81193 CONTROL VALVE (NATURAL) 1 81194 CONTROL VALVE (L.P.) 1 4 83251 10-24 x 1 SL ROD 2 5 83244 10-24 KEP NUT 2 N/S 83343 #10 X 1/2 HX HD SCREW 10 6 89831 BURNER/CONTROL FITTING 1 7 8983...
Page 19 - TROUBLESHOOTING; REMEDY
19 TROUBLESHOOTING Turn off and let cool before servicing. Only a qualified service person should serviceand repair heater. NOTE: All troubleshooting items are listed in order of operation. REMEDY POSSIBLE CAUSE OBSERVED PROBLEM When ignitor button is pressed, there isno spark at ODS/Pilot. Ignitor ...
Page 20 - POSSIBLE CAUSE
20 TROUBLESHOOTING, CONTINUED... ODS/Pilot lights, but flame goes outWhen control knob is released.(continued from page 19) One or both burner do notlight after ODS/pilot is lit. Burner backfires duringcombustion. Slight smoke or odor duringinitial operation. Logs appear to smoke afterinitial operat...
Page 21 - OPTIONAL F40 BLOWER KIT; HEATER OR YOU CAN ORDER DIRECT FROM THE FACTORY BY CONTACTING
21 OPTIONAL F40 BLOWER KIT THIS OPTIONAL F40 BLOWER KIT IS AVAILABLE WHERE YOU PURCHASED THIS HEATER OR YOU CAN ORDER DIRECT FROM THE FACTORY BY CONTACTING THE PARTS DEPARTMENT AT THE NUMBER AND ADDRESS ON THE BACK PAGE OF THIS MANUAL. BACK VIEW OF 9740
Page 22 - NOTES
Page 23 - LIMITED WARRANTY POLICY
23 This vent-free gas heater is warrantied for a period of one year, logs for oneyear, and burners for One Year, from date of purchase against defects inmaterial or workmanship. This warranty covers only the cost of defectiveparts and applies only to the original consumer purchaser. The replacemento...
Page 24 - OWNERS MANUAL; UNITED STATES STOVE COMPANY; The PART DESCRIPTION
24 OWNERS MANUAL HOW TO ORDER REPAIR PARTS OR "OPTIONS" UNITED STATES STOVE COMPANY 227 Industrial Park Rd., P.O. Box 151 South Pittsburg, TN 37380 (423) 837-2100 COMPANY U NI TED STATES STO VE C S S U BEFORE INSTALLING YOUR HEATER, FILL IN THE SERIALNUMBER IN THE SPACE PROVIDED ABOVE FOR YO...