Page 2 - TABLE OF CONTENTS
-2- TABLE OF CONTENTS TABLE OF CONTENTS .................................................................................................................2 SAFETY PRECAUTIONS...............................................................................................................3 SPECIFICATIONS...
Page 3 - SAFETY PRECAUTIONS
-3- SAFETY PRECAUTIONS IMPORTANT: Read this entire manual before installing and operating this product. Failure to do so may result in property damage, bodily injury, or even death. Proper installation of this stove is crucial for safe and efficient op-eration. Install vent at clearances specified b...
Page 4 - Keep foreign objects out of the hopper.
-4- SAFETY PRECAUTIONS Keep foreign objects out of the hopper. The moving parts of this stove are propelled by high torque electric motors. Keep all body parts away from the auger while the stove is plugged into an electrical outlet. These mov- ing parts may begin to move at any time while the stove...
Page 5 - SPECIFICATIONS; HEATING SPECIFICATIONS; SAFETY AND EPA COMPLIANCE; Ashley Heritage Model 5700; Electrical Rating
-5- SPECIFICATIONS HEATING SPECIFICATIONS 1 BTU output will vary depending on the quality of fuel. Use PFI listed fuels for the best results. 2 Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature. 3 Pellet size may effect the actu...
Page 6 - INSTALLATION; INSTALLATION OPTIONS; stove may be installed to code in either a; Ashley Heritage; stove, preferably an NFI certified; FLOOR PROTECTION; Your; stove will need a minimum 36 1/4” x 30 3/8” floor protector.
-6- INSTALLATION INSTALLATION OPTIONS Read this entire manual before you install and use your Ashley Heritage stove. Failure to follow instructions may result in property damage, bodily injury, or even death! (See specific installation details for clearances and other installation requirements) A Fr...
Page 7 - CLEARANCES; Distance “C” on the right-hand side of your; stove may need; TABLE 1
-7- INSTALLATION CLEARANCES Your Ashley Heritage Model 5700 stove has been tested and listed for installation in residential, mobile home, and alcove applications in accordance with the clearances given in FIGURES 3-5 and TABLE 1. NOTE: Distance “C” on the right-hand side of your Ashley Heritage Mod...
Page 8 - VENTING REQUIREMENTS; Install vent at clearances specified by the vent manufacturer.; MAXIMUM VENTING DISTANCE
-8- INSTALLATION VENTING REQUIREMENTS Install vent at clearances specified by the vent manufacturer. Do not connect the pellet vent to a vent serving any other appliance or stove. Do not install a flue damper in the exhaust venting system of this unit. The following installation guidelines must be f...
Page 9 - VENT TERMINATION CLEARANCES:; H) Minimum 1-foot clearance horizontally from combustible wall.; FIGURE 6
-9- INSTALLATION VENT TERMINATION CLEARANCES: A) Minimum 4-foot clearance below or beside any door or window that opens. B) Minimum 1-foot clearance above any door or window that opens. C) Minimum 3-foot clearance form any adjacent building. D) Minimum 7-foot clearance from any grade when adjacent t...
Page 10 - To vent the unit through the wall, connect the pipe; dealer should be able to pro-; THROUGH THE ROOF/CEILING INSTALLATION; FIGURE 7
-10- INSTALLATION THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION) To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the exhaust adapter is at least 18-inches above ground level, a straight section of pellet vent pipe can be used through the wall. Y...
Page 11 - OUTSIDE AIR SUPPLY; The use of outside air is mandatory for safe operation of this unit.; stove is 1 7/8” OD. The outside air connecting pipe; FIGURE 8; FIGURE 9
-11- INSTALLATION OUTSIDE AIR SUPPLY The use of outside air is mandatory for safe operation of this unit. For all installations it is mandatory that this unit be connected to an outside air supply . Metal pipe (solid or flexible) must be used for the outside air installation. PVC pipe is NOT approve...
Page 12 - SPECIAL MOBILE HOME REQUIREMENTS; WARNING! - DO NOT INSTALL IN A SLEEPING ROOM; The stove must be permanently attached to the floor.
-12- INSTALLATION SPECIAL MOBILE HOME REQUIREMENTS WARNING! - DO NOT INSTALL IN A SLEEPING ROOM CAUTION! - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. In addition to the previously detailed installation requirements, mobile home installations must me...
Page 13 - OPERATION
-13- OPERATION Do not operate your stove with the viewing or ash pan doors open. The upper auger will not feed pellets under these circumstances and a safety concern may arise from sparks or fumes entering the room. This heater is designed and approved for premium hardwood pellet fuel only. Any othe...
Page 14 - CONTROL PANEL; Ashley Heritage Model; “ON”; UNIT PREPARATION
-14- CONTROL PANEL Turning the stove OFF/ON, as well as adjustments for the fuel feed rate and room air fan speed are performed by pressing the appropriate but-ton(s) on the control panel which is located on the lower right-hand side of your Ashley Heritage Model 5700 stove (see FIGURE 11). Pressing...
Page 15 - SHUT DOWN PROCEDURE
-15- 4) Check that both augers and the exhaust blower are operating (the room air blower will not start at this time). DO NOT open the viewing door, the auto-start igniter will get very hot during this test. The stove will auto- matically shut down after approximately 23 minutes. START-UP PROCEDURE ...
Page 17 - MAINTENANCE; inspected and cleaned at least monthly; during the burning season.
-17- MAINTENANCE Failure to clean and maintain this unit as indicated can result in poor performance and safety haz-ards. Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust sys-tem for any inspection, cleaning, or maintenance work. Never perform any inspectio...
Page 18 - GLASS; FALL START UP; YEARLY SERVICING
-18- MAINTENANCE tact your Authorized “ Ashley Heritage ” Dealer to obtain a can of suitable high-temperature paint. GLASS We recommend using a high quality glass cleaner. Should a build up of creosote or carbon accumulate, you may wish to use 000 steel wool and water to clean the glass. In the even...
Page 20 - TROUBLE SHOOTING; Igniter
-20- TROUBLE SHOOTING PROBLEM CAUSE: Too rich air/fuel mixture • Clean out the burn plate and burn pot. • Check that the ash pan slides are completely closed. • Make sure that the viewing door is shut and sealed tightly. If not, adjust the door catch and/or replace the gaskets. • Check that the outs...
Page 22 - REPAIR PARTS DIAGRAM—MODEL 5700
Page 23 - REPAIR PARTS LIST—MODEL 5700; HOW TO ORDER REPAIR PARTS; United States Stove Company
-23- ITEM PART NO. DESCRIPTION ITEM PART NO. DESCRIPTION 1 69465B Main Weldment 23 40488 Auger Housing 2 69461 Impingment Plate Weldment 24 40489 Auger, Short 3 69462 Ash Dump Weldment 25 40490 Auger, Long 4 25361 Guide, Ash Dump Rod 26 88101 Gasket, Mounted Bearing 5 89954 Spring Handle 27 891105 M...
Page 24 - WIRING DIAGRAM
Page 25 - FACTORY DEFAULTS; FACTORY DEFAULT SETTINGS; Setting Description; deg F
-25- FACTORY DEFAULTS FACTORY DEFAULT SETTINGS Setting Description Default Value (P1) Auger Period Time limit for the upper auger period of operation. Display in is 1/10th sec. 16 sec (P2) Cold Stove Temp Low temperature limit that a warm stove must reach in order to shut down com-pletely. 95 deg F ...
Page 26 - SERVICE RECORD; DATE
-26- SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED