Page 2 - COPYRIGHT & TRADEMARKS; Specifications are subject to change without notice.; FCC STATEMENT; This device may not cause harmful interference.; CE Mark Warning
I COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used...
Page 4 - Audience; This Installation Guide is for:; Conventions
III Audience This Installation Guide is for: Network EngineerNetwork Administrator Conventions Due to the similarity in structure of TL-SL2210/TL-SL2218/TL-SL2428/TL-SL2452 Smart Switch, in this Installation Guide we take TL-SL2218 as an example to illustrate Chapter 2 Installation, Chapter 3 Lightn...
Page 5 - Contents
IV Contents Contents Chapter 1 Introduction —————————————— 01 1.1 Product Overview ......................................... 01 1.2 Appearance .................................................. 01 Chapter 2 Installation —————————————— 05 2.1 Package Contents ............................................
Page 6 - Product Overview; Front Panel
01 Smart Switch Introduction ChaCter C Product Overview C1C TL-SL2210/TL-SL2218/TL-SL2428/TL-SL2452 is compliant with the IEEE802.3 Ethernet protocols. These switches are equipped with powerful management interface, via which system, port, network, VLAN and priority can be configured. They provide a...
Page 8 - Port Feature; Model; Rear Panel; Rear Panel of
03 Smart Switch Port Feature Model 10/100Mbps RJ45 Port 10/100/1000Mbps RJ45 Port SFP Port TL-SL2210 8 1 1 TL-SL2218 16 2 2(Combo1 TL-SL2428 24 4 2(Combo1 TL-SL2452 48 2 2 Reset(RESET) With the switch powered on, press Reset button for five seconds to reset the software setting to its factory defaul...
Page 9 - Chapter 3 Lightning Protection; Please use the provided power cord.
04 Smart Switch The rear panel of TL-SL2218 is shown as Figure 1-6. Grounding Terminal Power Socket Rear Panel of Figure 1-6 TL-SL2218 The rear panel of TL-SL2428 is shown as Figure 1-7. Grounding Terminal Power Socket Rear Panel of Figure 1-7 TL-SL2428 The rear panel of TL-SL2452 is shown as Figure...
Page 10 - Package Contents; Safety Precautions
05 Smart Switch Installation ChaCter 1 Package Contents 11C Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Resource CD One Switch One Power Cord This Installation Guide Two mounting brackets and the fitt...
Page 11 - Site Requirements; Clearness; Dust the device regularly, and keep the indoor air clean.; Electromagnetic Interference
06 Smart Switch Site Requirements ■ To ensure normal operation and long service life of the device, please install it in an environment that meets the requirements described in the following subsection. Temperature/Humidity ȭ ȭ Please keep a proper temperature and humidity in the equipment room. Too...
Page 12 - Lightening Protection; C hapte r 3; Installation Site; Installation Tools
07 Smart Switch Keep the device far from high-frequency, strong-current devices, such as radio ■ transmitting station. Use electromagnetic shielding when necessary. ■ Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric dis...
Page 13 - Product Installation; Rack Installation
08 Smart Switch ESD-preventive wrist wrap ■ Cables ■ Note: These tools are not provided with our product. If needed, please self purchase them. Product Installation 112 Desktop Installation ■ To install the device on the desktop, please follow the steps: Set the device on a flat surface strong enoug...
Page 14 - Please set 5~10cm gaps around the device for air circulation.
09 Smart Switch Bracket Installation Figure 2-2 After the brackets are attached to the device, use suitable screws (not provided1 to 3. secure the brackets to the rack, as illustrated in the following figure. Rack Rack Installation Figure 2-3 Caution: Please set 5~10cm gaps around the device for air...
Page 15 - Cabling Reasonably; please use a signal lightning arrester.; Requirements for Cabling Outdoors; Aerial cabling without safeguard is not allowed.
10 Smart Switch Lightning Protection ChaCter 2 Cabling Reasonably 21C In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. ...
Page 16 - Requirements for Cabling Indoors; devices are in following tables.
11 Smart Switch Requirements for Cabling Indoors ■ When cabling indoors, keep a certain distance away from the devices that may cause high-frequenc y inter ferences, such as down-conduc tor cable, powerline, power transformer and electromotor. The main cable should be paved in the metal raceway of t...
Page 17 - Connect to Ground
12 Smart Switch 2~5kVA powerline Parallel cabling 300 One is in the grounded metal raceway or metal pipe 150 The both are in the grounded metal raceway or metal pipe 80 >5kVA powerline Parallel cabling 600 One is in the grounded metal raceway or metal pipe 300 The both are in the grounded metal r...
Page 18 - Connecting to the Ground via the Power Supply; EquiCotential Bonding
13 Smart Switch Note: The grounding bar and the ground cable are not provided with our product. If needed, please self purchase them. Connecting to the Ground via the Power Supply ■ If the device is installed in the normal environment, the device can be grounded via the PE (Protecting Earth1 cable o...
Page 19 - at least. The shorter cable the bet ter, and use a; Use Lightning Arrester
14 Smart Switch Grounding Terminal Equipotential Bonding CableGrounding Bar Ground Cable Equipotential Bonding Figure 3-3 When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm 2 at least. The shorter cable the bet ter, and use a grounding bar t...
Page 20 - Purchase a standard lightning arrester.
15 Smart Switch The port rate of the signal lightning arrester should match the rate of the desired ■ port on the device. If it is not matched, this signal lighting arrester will not work. Purchase a standard lightning arrester. Install signal lightning arrester near the protected device and connect...
Page 21 - Ethernet Port; Switching
16 Smart Switch Connection ChaCter 2 Ethernet Port 21C Please connect the Ethernet ports of the switch to the network devices by RJ45 cable as the following figure shown. RJ45 Port RJ45 Cable Connecting the RJ45 Port Figure 4-1 SFP Port 211 Connect the SFP port to a SFP module. For the switch, if an...
Page 22 - Verify Installation; the air flow is adequate.; Power On; Initialization; The Power LED lights on all the time.
17 Smart Switch Verify Installation 212 After completing the installation, please verify the following items: There are 5~10cm of clearance around the sides of the device for ventilation and ■ the air flow is adequate. The voltage of the power supply meets the requirement of the input voltage of the...
Page 23 - click the GO button or press the Enter key.
18 Smart Switch Login to the Switch ChaCter 4 To acce ss the GUI of the switch, open a web browser and t ype the default 1. management address http://192.168.0.1 in the address field of the browser, then click the GO button or press the Enter key. Web Browser Figure 5-1 Note: To log on to the GUI of...
Page 24 - ACCendix A Troubleshooting; What could I do if I forgot the username and Cassword of the; Why does the Power LED work abnormally?; QQQQ; Make sure that the power cable is connected properly, and the power; What could I do if I could not access the web-based configuration; QQQQ; You are recommended to check the following items:
19 Smart Switch ACCendix A Troubleshooting What could I do if I forgot the username and Cassword of the QQQQ switch? With the switch powered on, press the Reset button on the front panel for five seconds to reset the system to its factory default settings, and the default login user name and passwor...
Page 25 - ACCendix B Hardware SCecifications
20 Smart Switch ACCendix B Hardware SCecifications Item Content Standards and Protocol IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/100Base-FX IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-X IEEE 802.3x Flow Control Transmission Medium 10Base-T: UTP/STP of Cat. 3 or above 100Base-TX: UTP/STP of Cat. 5 ...
Page 26 - ACCendix C Technical SuCCort
21 Smart Switch ACCendix C Technical SuCCort For more help, please go to: http://www.tp-link.com/en/support/faq ■ To download the latest Firmware, Driver, Utility and User Guide, please go to: ■ http://www.tp-link.com/en/support/downloadFor all other technical support, please contact us by using the...